These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
119 related articles for article (PubMed ID: 11673669)
1. Enhanced cardiac thermal dilution measurement of cardiac output, volumes, regurgitation, valve effective diameters, ventricular power and efficiency -- Feasibility analysis using digital simulation. Donovan FM; Taylor BC Technol Health Care; 2001; 9(5):377-86. PubMed ID: 11673669 [TBL] [Abstract][Full Text] [Related]
2. [Data processing system for laboratory and hemodynamic heart catheterization measurements]. Jensch P; Meyer J; Mattar E; Ameling W; Effert S Z Kardiol; 1976 Oct; 65(10):850-81. PubMed ID: 997705 [TBL] [Abstract][Full Text] [Related]
3. Continuous registration of cardiac output with a new computer system designed for hot-film anemometry: an in vitro study. Hasenkam JM; Ostergaard JH; Pedersen EM; Paulsen PK; Nissen T Life Support Syst; 1986; 4(4):335-44. PubMed ID: 2951566 [TBL] [Abstract][Full Text] [Related]
4. Cardiac output regulation in the moving actuator total artificial heart without a compliance chamber. Kim HC; Min BG ASAIO J; 1992; 38(4):846-50. PubMed ID: 1450484 [TBL] [Abstract][Full Text] [Related]
5. [Analysis of factors influencing the accuracy of ejection fraction measurement based on the thermal washout technic--investigation in a model heart]. Imai T; Katoh K; Kani H; Fujita T; Ohno K; Nakayama T; Shioya S Masui; 1989 Apr; 38(4):475-82. PubMed ID: 2657127 [TBL] [Abstract][Full Text] [Related]
8. [Measurement of mean pulmonary pressures and right systolic ventricular pressure by radiocardiography]. Di Matteo J; Vacheron A; Meilhac B; de Vernejoul P; Fauchet M; Mestan J; Michaljavic A; Neumann J Arch Mal Coeur Vaiss; 1975 Jan; 68(1):3-9. PubMed ID: 804874 [TBL] [Abstract][Full Text] [Related]
9. [Measurement of the right ventricular ejection fraction by a rapid response thermistor catheter; evaluation using a circulatory model]. Kato K; Kani H; Arii H; Imai T; Fujita T Masui; 1986 Dec; 35(12):1778-83. PubMed ID: 3560406 [No Abstract] [Full Text] [Related]
10. Limitations of thermodilution ejection fraction: degradation of frequency response by catheter mounting of fast-response thermistors. Maruschak GF; Schauble JF Crit Care Med; 1985 Aug; 13(8):679-82. PubMed ID: 4017599 [TBL] [Abstract][Full Text] [Related]
11. Thermodilution technique for measurement of cardiac output during artificial ventilation. Jansen JR; Schreuder JJ; Bogaard JM; van Rooyen W; Versprille A J Appl Physiol Respir Environ Exerc Physiol; 1981 Sep; 51(3):584-91. PubMed ID: 7035418 [TBL] [Abstract][Full Text] [Related]
12. Effect of injectate temperature and thermistor position on reproducibility of thermodilution cardiac output determinations. Williams JE; Pfau SE; Deckelbaum LI Chest; 1994 Sep; 106(3):895-8. PubMed ID: 8082374 [TBL] [Abstract][Full Text] [Related]
13. [Thermodilution--an indicator dilution method to measure cardiac output and capacity of the ventricles]. Bentzen N; Hyldebrandt N; Madsen T Ugeskr Laeger; 1974 Jun; 136(25):1371-7. PubMed ID: 4601649 [No Abstract] [Full Text] [Related]
14. [Testing the regulation mechanism in inserting an artificial heart by model simulation]. Hecht J; Körner E Z Exp Chir Transplant Kunstliche Organe; 1987; 20(2):75-82. PubMed ID: 3604358 [TBL] [Abstract][Full Text] [Related]
15. [Error analysis of the thermoindicator method for the determination of the heart minute volume]. Bilfinger TV Anasth Intensivther Notfallmed; 1982 Aug; 17(4):215-9. PubMed ID: 7137541 [TBL] [Abstract][Full Text] [Related]
16. In vitro testing of a new driver for the pneumatic total artificial heart with inherent cardiac output measuring system. Frumento CI; Auch WD; Frumento AS Med Prog Technol; 1983-1984; 10(2):97-107. PubMed ID: 6674739 [TBL] [Abstract][Full Text] [Related]
17. Heat and mass transfer of a thermal indicator in pulsatile flow through the cardio-pulmonary system. II. Identification of cardiac output. Cassot F; Saadjian A; McKay C Med Prog Technol; 1978 May; 5(4):215-222. PubMed ID: 672825 [TBL] [Abstract][Full Text] [Related]
18. Mixing in the right ventricle and pulmonary artery in man: evaluation of ventricular volume measurements from indicator washout curves. Maseri A; Enson Y J Clin Invest; 1968 Apr; 47(4):848-59. PubMed ID: 4868033 [TBL] [Abstract][Full Text] [Related]
19. An evaluation of thermodilution cardiac output measurement using the Swan-Ganz catheter. Runciman WB; Ilsley AH; Roberts JG Anaesth Intensive Care; 1981 Aug; 9(3):208-20. PubMed ID: 7025698 [TBL] [Abstract][Full Text] [Related]
20. Time constant of thermistors and its role in thermodilution methods. Zajic F; Brun Z; Novotny M Cor Vasa; 1975; 17(3):204-11. PubMed ID: 1106949 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]