These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 11674823)

  • 1. Potential therapeutic misadministration due to inappropriate electron beam field shaping.
    Olch AJ; Fallen R; Conrad J; Lavey RS
    J Appl Clin Med Phys; 2000; 1(3):95-9. PubMed ID: 11674823
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A dosimetric comparison of copper and Cerrobend electron inserts.
    Rusk BD; Carver RL; Gibbons JP; Hogstrom KR
    J Appl Clin Med Phys; 2016 Sep; 17(5):245–261. PubMed ID: 27685126
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The dosimetric properties of an applicator system for intraoperative electron-beam therapy utilizing a Clinac-18 accelerator.
    McCullough EC; Anderson JA
    Med Phys; 1982; 9(2):261-8. PubMed ID: 6806596
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison between small radiation therapy electron beams collimated by Cerrobend and tubular applicators.
    Di Venanzio C; Marinelli M; Tonnetti A; Verona-Rinati G; Bagalà P; Falco MD; Guerra AS; Pimpinella M
    J Appl Clin Med Phys; 2015 Jan; 16(1):5186. PubMed ID: 25679175
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The peripheral dose outside the applicator in electron beams of Oncor linear accelerator.
    Iktueren B; Bilge H; Karacam S; Atkovar G
    Radiat Prot Dosimetry; 2012 Jun; 150(2):192-7. PubMed ID: 22025738
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monte Carlo commissioning of clinical electron beams using large field measurements.
    O'Shea TP; Sawkey DL; Foley MJ; Faddegon BA
    Phys Med Biol; 2010 Jul; 55(14):4083-105. PubMed ID: 20601775
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of electron cutouts on absorbed dose in and outside Varian-20 electron fields.
    Kubo H
    Med Dosim; 1990 Jun; 15(2):61-6. PubMed ID: 2118360
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Development of special electron applicators for intraoperative radiotherapy at the Grosshadern Clinic].
    Krimmel K; Willich N; Denecke H
    Strahlenther Onkol; 1990 Mar; 166(3):218-23. PubMed ID: 2109357
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Tungsten filled 3D printed field shaping devices for electron beam radiation therapy.
    Skinner L; Fahimian BP; Yu AS
    PLoS One; 2019; 14(6):e0217757. PubMed ID: 31216296
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intraoperative radiation therapy using a mobile electron linear accelerator: field matching for large-field electron irradiation.
    Beddar AS; Briere TM; Ouzidane M
    Phys Med Biol; 2006 Sep; 51(18):N331-7. PubMed ID: 16953035
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Leakage radiation from electron applicators on a medical accelerator.
    Pennington EC; Jani SK; Wen BC
    Med Phys; 1988; 15(5):763-5. PubMed ID: 3141759
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.
    Cardenas CE; Nitsch PL; Kudchadker RJ; Howell RM; Kry SF
    J Appl Clin Med Phys; 2016 Jul; 17(4):442-455. PubMed ID: 27455499
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparing the dosimetric characteristics of the electron beam from dedicated intraoperative and conventional radiotherapy accelerators.
    Baghani HR; Aghamiri SM; Mahdavi SR; Akbari ME; Mirzaei HR
    J Appl Clin Med Phys; 2015 Mar; 16(2):5017. PubMed ID: 26103175
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Levels of leakage radiation from electron collimators of a linear accelerator.
    Das KR; Cramb JA; Millar RM; Kenny MB; Patterson WR; Ackerly TL; Perkins AE; Chongkitivitya K
    Med Phys; 1990; 17(6):1058-63. PubMed ID: 2126336
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiation leakage from linac electron applicator assembly.
    Keys RA; Purdy JA
    Int J Radiat Oncol Biol Phys; 1984 May; 10(5):713-21. PubMed ID: 6429095
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wall-scattering effects in electron beam collimation.
    van der Laarse R; Bruinvis IA; Nooman MF
    Acta Radiol Oncol Radiat Phys Biol; 1978; 17(2):113-24. PubMed ID: 99983
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Commissioning of a mobile electron accelerator for intraoperative radiotherapy.
    Mills MD; Fajardo LC; Wilson DL; Daves JL; Spanos WJ
    J Appl Clin Med Phys; 2001; 2(3):121-30. PubMed ID: 11602008
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electron beam characteristics on a Philips SL25.
    Palta JR; Daftari IK; Ayyangar KM; Suntharalingam N
    Med Phys; 1990; 17(1):27-34. PubMed ID: 2106612
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A study on virtual source position for electron beams from a Mevatron MD linear accelerator.
    Ravindran BP
    Phys Med Biol; 1999 May; 44(5):1309-15. PubMed ID: 10368021
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Scattered radiation from applicators in clinical electron beams.
    van Battum LJ; van der Zee W; Huizenga H
    Phys Med Biol; 2003 Aug; 48(15):2493-507. PubMed ID: 12953911
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.