BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 11679237)

  • 1. Clinical evaluation of the GlucoWatch biographer: a continual, non-invasive glucose monitor for patients with diabetes.
    Tierney MJ; Tamada JA; Potts RO; Jovanovic L; Garg S;
    Biosens Bioelectron; 2001 Dec; 16(9-12):621-9. PubMed ID: 11679237
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The GlucoWatch biographer: a frequent automatic and noninvasive glucose monitor.
    Tierney MJ; Tamada JA; Potts RO; Eastman RC; Pitzer K; Ackerman NR; Fermi SJ
    Ann Med; 2000 Dec; 32(9):632-41. PubMed ID: 11209971
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Glucose monitoring by reverse iontophoresis.
    Potts RO; Tamada JA; Tierney MJ
    Diabetes Metab Res Rev; 2002; 18 Suppl 1():S49-53. PubMed ID: 11921430
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of acetaminophen on the accuracy of glucose measurements obtained with the GlucoWatch biographer.
    Tierney MJ; Garg S; Ackerman NR; Fermi SJ; Kennedy J; Lopatin M; Potts RO; Tamada JA
    Diabetes Technol Ther; 2000; 2(2):199-207. PubMed ID: 11469259
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Noninvasive glucose monitoring: comprehensive clinical results. Cygnus Research Team.
    Tamada JA; Garg S; Jovanovic L; Pitzer KR; Fermi S; Potts RO
    JAMA; 1999 Nov; 282(19):1839-44. PubMed ID: 10573275
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes.
    Garg SK; Potts RO; Ackerman NR; Fermi SJ; Tamada JA; Chase HP
    Diabetes Care; 1999 Oct; 22(10):1708-14. PubMed ID: 10526740
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of the GlucoWatch biographer in children and adolescents with diabetes.
    Eastman RC; Chase HP; Buckingham B; Hathout EH; Fuller-Byk L; Leptien A; Van Wyhe MM; Davis TL; Fermi SJ; Pechler H; Sahyun G; Lopatin M; Wang BY; Wei C; Bartkowiak M; Ginsberg BH; Tamada JA; Pitzer KR
    Pediatr Diabetes; 2002 Sep; 3(3):127-34. PubMed ID: 15016152
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of the Cygnus GlucoWatch biographer at a diabetes camp.
    Gandrud LM; Paguntalan HU; Van Wyhe MM; Kunselman BL; Leptien AD; Wilson DM; Eastman RC; Buckingham BA
    Pediatrics; 2004 Jan; 113(1 Pt 1):108-11. PubMed ID: 14702457
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Detection of hypoglycemia with the GlucoWatch biographer.
    Pitzer KR; Desai S; Dunn T; Edelman S; Jayalakshmi Y; Kennedy J; Tamada JA; Potts RO
    Diabetes Care; 2001 May; 24(5):881-5. PubMed ID: 11347748
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of preapplication of corticosteroids on skin irritation and performance of the GlucoWatch G2 Biographer.
    Tamada JA; Davis TL; Leptien AD; Lee J; Wang B; Lopatin M; Wei C; Wilson D; Comyns K; Eastman RC
    Diabetes Technol Ther; 2004 Jun; 6(3):357-67. PubMed ID: 15198839
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of the GlucoWatch biographer in children with type 1 diabetes.
    Chase HP; Roberts MD; Wightman C; Klingensmith G; Garg SK; Van Wyhe M; Desai S; Harper W; Lopatin M; Bartkowiak M; Tamada J; Eastman RC
    Pediatrics; 2003 Apr; 111(4 Pt 1):790-4. PubMed ID: 12671113
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Physiological differences between interstitial glucose and blood glucose measured in human subjects.
    Kulcu E; Tamada JA; Reach G; Potts RO; Lesho MJ
    Diabetes Care; 2003 Aug; 26(8):2405-9. PubMed ID: 12882870
    [TBL] [Abstract][Full Text] [Related]  

  • 13. GlucoWatch Biographer. An automatic, noninvasive glucose monitor.
    Health Devices; 2002 Aug; 31(8):295-302. PubMed ID: 12530360
    [No Abstract]   [Full Text] [Related]  

  • 14. Rates of glucose change measured by blood glucose meter and the GlucoWatch Biographer during day, night, and around mealtimes.
    Dunn TC; Eastman RC; Tamada JA
    Diabetes Care; 2004 Sep; 27(9):2161-5. PubMed ID: 15333478
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of the noninvasive GlucoWatch Biographer during exercise of varying intensity.
    Nunnold T; Colberg SR; Herriott MT; Somma CT
    Diabetes Technol Ther; 2004 Aug; 6(4):454-62. PubMed ID: 15320999
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical experience of an iontophoresis based glucose measuring system.
    Rhee SY; Chon S; Koh G; Paeng JR; Oh S; Woo JT; Kim SW; Kim JW; Kim YS
    J Korean Med Sci; 2007 Feb; 22(1):70-3. PubMed ID: 17297254
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Glucowatch Biographer: a noninvasive glucose monitoring device.
    Med Lett Drugs Ther; 2001 May; 43(1104):42. PubMed ID: 11353926
    [No Abstract]   [Full Text] [Related]  

  • 18. Clinical evaluation of a continuous minimally invasive glucose flux sensor placed over ultrasonically permeated skin.
    Chuang H; Taylor E; Davison TW
    Diabetes Technol Ther; 2004 Feb; 6(1):21-30. PubMed ID: 15000766
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Results of continuous glucose monitoring by GlucoWatch Biographer in a cohort of diabetic children and adolescents under real-life conditions.
    Bozzetti V; Viscardi M; Bonfanti R; Azzinari A; Meschi F; Bognetti E; Chiumello G
    Pediatr Diabetes; 2003 Mar; 4(1):57-8. PubMed ID: 14655524
    [No Abstract]   [Full Text] [Related]  

  • 20. The surveillance error grid.
    Klonoff DC; Lias C; Vigersky R; Clarke W; Parkes JL; Sacks DB; Kirkman MS; Kovatchev B;
    J Diabetes Sci Technol; 2014 Jul; 8(4):658-72. PubMed ID: 25562886
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.