These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

241 related articles for article (PubMed ID: 11681337)

  • 1. [Appraisal and analysis of heat removing characteristic of liquid cooling garment using thermal manikin].
    Zhang WX; Chen JS; Li TQ; Zhao YJ; Li Z
    Space Med Med Eng (Beijing); 2001 Aug; 14(4):257-60. PubMed ID: 11681337
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [A heat transfer model for liquid cooling garment (LCG) and its analysis].
    Zhang WX; Chen JS; Li TQ
    Space Med Med Eng (Beijing); 2000 Oct; 13(5):350-4. PubMed ID: 11894874
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Heat transfer analysis of liquid cooling garment used for extravehicular activity].
    Qiu YF; Yuan XG; Mei ZG; Jia SG; Ouyang H; Ren ZS
    Space Med Med Eng (Beijing); 2001 Oct; 14(5):364-7. PubMed ID: 11845824
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficiency of liquid cooling garments: prediction and manikin measurement.
    Xu X; Endrusick T; Laprise B; Santee W; Kolka M
    Aviat Space Environ Med; 2006 Jun; 77(6):644-8. PubMed ID: 16780244
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Model of human/liquid cooling garment interaction for space suit automatic thermal control.
    Nyberg KL; Diller KR; Wissler EH
    J Biomech Eng; 2001 Feb; 123(1):114-20. PubMed ID: 11277296
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Research progress of thermal control system for extravehicular activity space suit].
    Wu ZQ; Shen LP; Yuan XG
    Space Med Med Eng (Beijing); 1999 Aug; 12(4):303-7. PubMed ID: 11542717
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of thermal manikin surface temperature on the performance of personal cooling systems.
    Jetté FX; Dionne JP; Rose J; Makris A
    Eur J Appl Physiol; 2004 Sep; 92(6):669-72. PubMed ID: 15106006
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design process for developing a liquid cooling garment hood.
    Kim DE; LaBat K
    Ergonomics; 2010 Jun; 53(6):818-28. PubMed ID: 20496248
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thermoregulation and heat exchange in a nonuniform thermal environment during simulated extended EVA. Extravehicular activities.
    Koscheyev VS; Leon GR; Hubel A; Nelson ED; Tranchida D
    Aviat Space Environ Med; 2000 Jun; 71(6):579-85. PubMed ID: 10870816
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [The present status and development of thermal control system of spacesuits for extravehicular activity].
    Zhao CY; Sun JB; Yuan XG
    Space Med Med Eng (Beijing); 1999 Apr; 12(2):149-53. PubMed ID: 12430554
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Effects of head-down bedrest on surface temperature distribution and non-evaporative heat dissipation].
    Qiu M; Wu JM; Gu DL; Yu XJ; Yuan XG; Chen JS
    Space Med Med Eng (Beijing); 2002 Apr; 15(2):93-7. PubMed ID: 12068890
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Multi-loop control of liquid cooling garment systems.
    Xu X; Hexamer M; Werner J
    Ergonomics; 1999 Feb; 42(2):282-98. PubMed ID: 10024848
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automatic control of thermal neutrality for space suit applications using a liquid cooling garment.
    Nyberg KL; Diller KR; Wissler EH
    Aviat Space Environ Med; 2000 Sep; 71(9):904-13. PubMed ID: 11001343
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Numerical study of the effects (correction of efects) of size of inlets and outlets of ventilation system in experimental space station cabin].
    Wu H; Li N; Liang XG; Guo ZY
    Space Med Med Eng (Beijing); 2001 Aug; 14(4):268-71. PubMed ID: 11681340
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Thermal physiological analysis of man in an Intravehicular Activity space suit].
    Yu XJ; Chang SY; Wu JM; Qiu M; Wen JF; Yang TD
    Space Med Med Eng (Beijing); 1999 Oct; 12(5):356-9. PubMed ID: 12022181
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Skin temperature feedback optimizes microclimate cooling.
    Stephenson LA; Vernieuw CR; Leammukda W; Kolka MA
    Aviat Space Environ Med; 2007 Apr; 78(4):377-82. PubMed ID: 17484339
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of different cooling regimes within a shortened liquid cooling/warming garment on physiological and psychological comfort during exercise.
    Leon GR; Koscheyev VS; Coca A; List N
    Habitation (Elmsford); 2004; 10(1):61-7. PubMed ID: 15880910
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Mass optimization of thermal network model of coupled dual-loop thermal control system in spacecraft].
    Zhang XR; Ren JX; Xu XH; Liang XG
    Space Med Med Eng (Beijing); 2001 Aug; 14(4):277-81. PubMed ID: 11681342
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Subjective perceptions and ergonomics evaluation of a liquid cooled garment worn under protective ensemble during an intermittent treadmill exercise.
    Kim JH; Coca A; Williams WJ; Roberge RJ
    Ergonomics; 2011 Jul; 54(7):626-35. PubMed ID: 21770750
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Skin blood flow with elastic compressive extravehicular activity space suit.
    Tanaka K; Gotoh TM; Morita H; Hargens AR
    Biol Sci Space; 2003 Oct; 17(3):227. PubMed ID: 14676389
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.