BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 11686273)

  • 1. Optimization of field-cycled PEDRI for in vivo imaging of free radicals.
    Youngdee W; Planinsic G; Lurie DJ
    Phys Med Biol; 2001 Oct; 46(10):2531-44. PubMed ID: 11686273
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Young Investigator Award presentation at the 13th Annual Meeting of the ESMRMB, September 1996, Prague. A proton-electron double-resonance imaging apparatus with simultaneous multiple electron paramagnetic resonance irradiation at 10 mT.
    Alecci M; Lurie DJ; Nicholson I; Placidi G; Sotgiu A
    MAGMA; 1996; 4(3-4):187-93. PubMed ID: 9220407
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rapid imaging of free radicals in vivo using field cycled PEDRI.
    Puwanich P; Lurie DJ; Foster MA
    Phys Med Biol; 1999 Dec; 44(12):2867-77. PubMed ID: 10616141
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rapid imaging of free radicals in vivo using hybrid FISP field-cycled PEDRI.
    Youngdee W; Lurie DJ; Foster MA
    Phys Med Biol; 2002 Apr; 47(7):1091-100. PubMed ID: 11996057
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Dynamic Nuclear Polarization spectrometer at 95 GHz/144 MHz with EPR and NMR excitation and detection capabilities.
    Feintuch A; Shimon D; Hovav Y; Banerjee D; Kaminker I; Lipkin Y; Zibzener K; Epel B; Vega S; Goldfarb D
    J Magn Reson; 2011 Apr; 209(2):136-41. PubMed ID: 21296015
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Field-cycled PEDRI imaging of free radicals with detection at 450 mT.
    Lurie DJ; Davies GR; Foster MA; Hutchison JM
    Magn Reson Imaging; 2005 Feb; 23(2):175-81. PubMed ID: 15833609
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design, construction and use of a large-sample field-cycled PEDRI imager.
    Lurie DJ; Foster MA; Yeung D; Hutchison JM
    Phys Med Biol; 1998 Jul; 43(7):1877-86. PubMed ID: 9703050
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A versatile and modular quasi optics-based 200GHz dual dynamic nuclear polarization and electron paramagnetic resonance instrument.
    Siaw TA; Leavesley A; Lund A; Kaminker I; Han S
    J Magn Reson; 2016 Mar; 264():131-153. PubMed ID: 26920839
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A novel variable field system for field-cycled dynamic nuclear polarization spectroscopy.
    Shet K; Caia GL; Kesselring E; Samouilov A; Petryakov S; Lurie DJ; Zweier JL
    J Magn Reson; 2010 Aug; 205(2):202-8. PubMed ID: 20570197
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-frequency dynamic nuclear polarization using mixtures of TEMPO and trityl radicals.
    Hu KN; Bajaj VS; Rosay M; Griffin RG
    J Chem Phys; 2007 Jan; 126(4):044512. PubMed ID: 17286492
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Low field (10 mT) pulsed dynamic nuclear polarization.
    Alecci M; Lurie DJ
    J Magn Reson; 1999 Jun; 138(2):313-9. PubMed ID: 10341136
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In Vivo Application of Proton-Electron Double-Resonance Imaging.
    Kishimoto S; Krishna MC; Khramtsov VV; Utsumi H; Lurie DJ
    Antioxid Redox Signal; 2018 May; 28(15):1345-1364. PubMed ID: 28990406
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-field dynamic nuclear polarization in aqueous solutions.
    Prandolini MJ; Denysenkov VP; Gafurov M; Endeward B; Prisner TF
    J Am Chem Soc; 2009 May; 131(17):6090-2. PubMed ID: 19361195
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correlation of the EPR properties of perchlorotriphenylmethyl radicals and their efficiency as DNP polarizers.
    Banerjee D; Paniagua JC; Mugnaini V; Veciana J; Feintuch A; Pons M; Goldfarb D
    Phys Chem Chem Phys; 2011 Nov; 13(41):18626-37. PubMed ID: 21946909
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Free Radical Imaging Using In Vivo Dynamic Nuclear Polarization-MRI.
    Utsumi H; Hyodo F
    Methods Enzymol; 2015; 564():553-71. PubMed ID: 26477265
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Advantageous application of a surface coil to EPR irradiation in overhauser-enhanced MRI.
    Matsumoto S; Yamada K; Hirata H; Yasukawa K; Hyodo F; Ichikawa K; Utsumi H
    Magn Reson Med; 2007 Apr; 57(4):806-11. PubMed ID: 17390363
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of multi-coil parallel-gap resonators for co-registration EPR/NMR imaging.
    Kawada Y; Hirata H; Fujii H
    J Magn Reson; 2007 Jan; 184(1):29-38. PubMed ID: 17029883
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sequential, co-registered fluorine and proton field-cycled Overhauser imaging at a detection field of 59 mT.
    Modica A; Lurie DJ; Alecci M
    Phys Med Biol; 2006 Feb; 51(3):N39-45. PubMed ID: 16424574
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimization of dynamic nuclear polarization experiments in aqueous solution at 15 MHz/9.7 GHz: a comparative study with DNP at 140 MHz/94 GHz.
    Türke MT; Tkach I; Reese M; Höfer P; Bennati M
    Phys Chem Chem Phys; 2010 Jun; 12(22):5893-901. PubMed ID: 20454734
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Water accessibility in a membrane-inserting peptide comparing Overhauser DNP and pulse EPR methods.
    Segawa TF; Doppelbauer M; Garbuio L; Doll A; Polyhach YO; Jeschke G
    J Chem Phys; 2016 May; 144(19):194201. PubMed ID: 27208942
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.