These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 11699516)

  • 1. Clinical validation of new pacing-sensing configurations for atrial automatic capture verification in pacemakers.
    Butter C; Hartung WM; Kay GN; Willems R; Zhang G; Lang DJ; Fleck E
    J Cardiovasc Electrophysiol; 2001 Oct; 12(10):1104-8. PubMed ID: 11699516
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reduction of pacing output coupling capacitance for sensing the evoked response.
    Sperzel J; Neuzner J; Schwarz T; Zhu Q; König A; Kay GN
    Pacing Clin Electrophysiol; 2001 Sep; 24(9 Pt 1):1377-82. PubMed ID: 11584460
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance evaluation of a right atrial automatic capture verification algorithm using two different sensing configurations.
    Sperzel J; Goetze S; Kennergren C; Biffi M; Brooke MJ; Vireca E; Saha S; Schubert B; Butter C
    Pacing Clin Electrophysiol; 2009 May; 32(5):579-87. PubMed ID: 19422578
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of atrial lead position on atrial automatic capture verification.
    Butter C; Zhang G; Seifert M; Minden HH; König A; Fleck E
    Pacing Clin Electrophysiol; 2008 Sep; 31(9):1118-24. PubMed ID: 18834462
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Atrial pacing and sensing characteristics in heart failure patients undergoing cardiac resynchronization therapy.
    Schuchert A; Aydin MA; Israel C; Gaby G; Paul V
    Europace; 2005 Mar; 7(2):165-9. PubMed ID: 15763532
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automatic capture verification by charge-neutral sensing.
    Kadhiresan VA; Olive A; Gornick C; Spinelli J; Villalta D
    Pacing Clin Electrophysiol; 1999 Jan; 22(1 Pt 1):73-8. PubMed ID: 9990603
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Atrial evoked response integral for automatic capture verification in atrial pacing.
    Boriani G; Biffi M; Cameron D; Datteri S; Snell J; Holmström N; Park E; Bornzin GA
    Pacing Clin Electrophysiol; 2003 Jan; 26(1P2):248-52. PubMed ID: 12687822
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automatic capture verification in ICD lead systems using intracardiac ventricular evoked response and reduced coupling capacitance.
    Sperzel J; Pitschner HF; Schwarz T; König A; Zhu Q; Neuzner J
    Europace; 2003 Jan; 5(1):83-9. PubMed ID: 12504646
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of electrode position on atrial sensing for physiologically responsive cardiac pacemakers.
    Timmis GC; Westveer DC; Gadowski G; Stewart JR; Gordon S
    Am Heart J; 1984 Oct; 108(4 Pt 1):909-16. PubMed ID: 6486002
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experience and implantation techniques with a new single-pass lead VDD pacing system.
    Longo E; Catrini V
    Pacing Clin Electrophysiol; 1990 Jul; 13(7):927-36. PubMed ID: 1695750
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automatic management of atrial and ventricular stimulation in a contemporary unselected population of pacemaker recipients: the ESSENTIAL Registry.
    Biffi M; Bertini M; Saporito D; Belotti G; Quartieri F; Piancastelli M; Pucci A; Boggian G; Mazzocca GF; Giorgi D; Diotallevi P; Diemberger I; Martignani C; Pancaldi S; Ziacchi M; Marcantoni L; Toselli T; Attala S; Iori M; Bottoni N; Argnani S; Tomasi C; Sassone B; Boriani G
    Europace; 2016 Oct; 18(10):1551-1560. PubMed ID: 27305923
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Single lead DDD system: a comparative evaluation of unipolar, bipolar, and overlapping biphasic stimulation and the effects of right atrial floating electrode location on atrial pacing and sensing thresholds.
    Tse HF; Lau CP; Leung SK; Leung Z; Mehta N
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1758-63. PubMed ID: 8945035
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Alternate methods for the determination of atrial capture threshold utilizing the telemetered intracardiac electrogram.
    Feuer JM; Florio J; Shandling AH
    Pacing Clin Electrophysiol; 1990 Oct; 13(10):1254-60. PubMed ID: 1701540
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evolution of an active fixation atrial pacing lead.
    Schwaab B; Kindermann M; Frohlig G; Kusch O; Schieffer H
    Pacing Clin Electrophysiol; 2000 Nov; 23(11 Pt 2):1795-7. PubMed ID: 11139926
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Autocapture enhancements: unipolar and bipolar lead compatibility and bipolar pacing capability on bipolar leads.
    Binner L; Messenger J; Sperzel J; Bondke H; Vandekerckhove Y; Poore J; Scheiner J; Berkhof M; Park E; Holmström N; Bornzin GA
    Pacing Clin Electrophysiol; 2003 Jan; 26(1P2):221-4. PubMed ID: 12687816
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A new pacemaker algorithm for continuous capture verification and automatic threshold determination: elimination of pacemaker afterpotential utilizing a triphasic charge balancing system.
    Feld GK; Love CJ; Camerlo J; Marsella R
    Pacing Clin Electrophysiol; 1992 Feb; 15(2):171-8. PubMed ID: 1372416
    [TBL] [Abstract][Full Text] [Related]  

  • 17. VDD(R) pacing: short- and long-term stability of atrial sensing with a single lead system.
    Naegeli B; Osswald S; Pfisterer M; Burkart F
    Pacing Clin Electrophysiol; 1996 Apr; 19(4 Pt 1):455-64. PubMed ID: 8848393
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative evaluation of acute and long-term clinical performance of two single lead atrial synchronous ventricular (VDD) pacemakers: diagonally arranged bipolar versus closely spaced bipolar ring electrodes.
    Lau CP; Leung SK; Lee IS
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 1):1574-81. PubMed ID: 8946453
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pacing threshold trends and variability in modern tined leads assessed using high resolution automatic measurements: conversion of pulse width into voltage thresholds.
    Danilovic D; Ohm OJ
    Pacing Clin Electrophysiol; 1999 Apr; 22(4 Pt 1):567-87. PubMed ID: 10234710
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Atrial fibrillation reduces the atrial impedance amplitude during cardiac cycle: a novel detection algorithm to improve recognition of atrial fibrillation in pacemaker patients.
    Schmidt B; Asbach S; Schweika O; Zehender M; Bode C; Faber TS
    Europace; 2007 Sep; 9(9):812-6. PubMed ID: 17545214
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.