BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 11704463)

  • 1. Immobilization in stereotactic radiotherapy: the head and neck localizer frame.
    Fairclough-Tompa L; Larsen T; Jaywant SM
    Med Dosim; 2001; 26(3):267-73. PubMed ID: 11704463
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Phantom dosimetry for conformal stereotactic radiotherapy with a head and neck localizer frame.
    Ravindra BP; Fairclough L; Jaywant SM
    Phys Med Biol; 2001 Jul; 46(7):1975-84. PubMed ID: 11474938
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Evaluation of positioning reproducibility using a re-locatable head frame for stereotactic radiotherapy].
    Miyabe Y; Yano S; Okada T; Nakata M; Teshima T; Nagata Y; Hiraoka M
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2004 Oct; 60(10):1444-51. PubMed ID: 15565014
    [TBL] [Abstract][Full Text] [Related]  

  • 4. To frame or not to frame? Cone-beam CT-based analysis of head immobilization devices specific to linac-based stereotactic radiosurgery and radiotherapy.
    Babic S; Lee Y; Ruschin M; Lochray F; Lightstone A; Atenafu E; Phan N; Mainprize T; Tsao M; Soliman H; Sahgal A
    J Appl Clin Med Phys; 2018 Mar; 19(2):111-120. PubMed ID: 29363282
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of a relocatable stereotactic radiotherapy head frame evaluated by use of a depth helmet.
    Burton KE; Thomas SJ; Whitney D; Routsis DS; Benson RJ; Burnet NG
    Clin Oncol (R Coll Radiol); 2002 Feb; 14(1):31-9. PubMed ID: 11898783
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Adaptation and verification of the relocatable Gill-Thomas-Cosman frame in stereotactic radiotherapy.
    Kooy HM; Dunbar SF; Tarbell NJ; Mannarino E; Ferarro N; Shusterman S; Bellerive M; Finn L; McDonough CV; Loeffler JS
    Int J Radiat Oncol Biol Phys; 1994 Oct; 30(3):685-91. PubMed ID: 7928501
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Modification of Gill-Thomas-Cosman frame for extracranial head-and-neck stereotactic radiotherapy.
    Kassaee A; Das IJ; Tochner Z; Rosenthal DI
    Int J Radiat Oncol Biol Phys; 2003 Nov; 57(4):1192-5. PubMed ID: 14575852
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fractionated stereotactic radiotherapy for pediatric patients with retinoblastoma.
    Higgins PD; Gerbi BJ; Macedon M; Dusenbery KE
    J Appl Clin Med Phys; 2006 May; 7(2):9-17. PubMed ID: 17533322
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Feasibility of patient immobilization for conventional cranial irradiation with a relocatable stereotactic frame.
    Laing RW; Thompson V; Warrington AP; Brada M
    Br J Radiol; 1993 Nov; 66(791):1020-4. PubMed ID: 8281377
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of relocation, evaluation of geometric uncertainties and clinical target volume (CTV) to planning target volume (PTV) margin in fractionated stereotactic radiotherapy for intracranial tumors using relocatable Gill-Thomas-Cosman (GTC) frame.
    Das S; Isiah R; Rajesh B; Ravindran BP; Singh RR; Backianathan S; Subhashini J
    J Appl Clin Med Phys; 2010 Dec; 12(2):3260. PubMed ID: 21587166
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stereotactic radiotherapy in the treatment of ocular melanoma: a noninvasive eye fixation aid and tracking system.
    Jaywant SM; Osei EK; Ladak S
    J Appl Clin Med Phys; 2003; 4(2):156-61. PubMed ID: 12777151
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Relocatable frame for stereotactic external beam radiotherapy.
    Gill SS; Thomas DG; Warrington AP; Brada M
    Int J Radiat Oncol Biol Phys; 1991 Mar; 20(3):599-603. PubMed ID: 1995547
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stereotactic multiple arc radiotherapy.
    Thomson ES; Gill SS; Doughty D
    Br J Radiol; 1990 Oct; 63(754):745-51. PubMed ID: 2122924
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Minimally invasive stereotaxy: clinical use of the Gill-Thomas-Cosman (GTC) repeat stereotactic localiser.
    Kitchen ND; Thomas DG
    Minim Invasive Neurosurg; 1994 Dec; 37(2):61-3. PubMed ID: 7882078
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Report on a randomized trial comparing two forms of immobilization of the head for fractionated stereotactic radiotherapy.
    Bednarz G; Machtay M; Werner-Wasik M; Downes B; Bogner J; Hyslop T; Galvin J; Evans J; Curran W; Andrews D
    Med Phys; 2009 Jan; 36(1):12-7. PubMed ID: 19235368
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Stereotactic IMRT for prostate cancer: setup accuracy of a new stereotactic body localization system.
    Wang L; Jacob R; Chen L; Ma C; Movsas B; Feigenberg S; Konski A
    J Appl Clin Med Phys; 2004; 5(2):18-28. PubMed ID: 15738910
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Patient position reproducibility in fractionated stereotactic radiotherapy: an update after changing dental impression material.
    Rosenberg I; Alheit H; Beardmore C; Lee KS; Warrington AP; Brada M
    Radiother Oncol; 1999 Feb; 50(2):239-40. PubMed ID: 10368049
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A new non-invasive and relocatable immobilization frame for fractionated stereotactic radiotherapy.
    Theodorou K; Kappas C; Tsokas C
    Radiother Oncol; 1998 Jun; 47(3):313-7. PubMed ID: 9681896
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stereotactic radiotherapy for pediatric and adult brain tumors: preliminary report.
    Dunbar SF; Tarbell NJ; Kooy HM; Alexander E; Black PM; Barnes PD; Goumnerova L; Scott RM; Pomeroy SL; La Vally B
    Int J Radiat Oncol Biol Phys; 1994 Oct; 30(3):531-9. PubMed ID: 7928483
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Noninvasive head fixation for external irradiation of tumors of the head-neck area].
    Bale RJ; Sweeney R; Vogele M; Nevinny M; Auer T; Bluhm A; Thumfart WF; Lukas P
    Strahlenther Onkol; 1998 Jul; 174(7):350-4. PubMed ID: 9689955
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.