These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
44. New thoughts on CJD, surgical instruments and disease transmission. Williams D Med Device Technol; 2006; 17(1):7-8. PubMed ID: 16483102 [TBL] [Abstract][Full Text] [Related]
45. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients]. Schlote T; Landenberger H Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316 [TBL] [Abstract][Full Text] [Related]
46. Measurement of Goldmann applanation tonometer calibration error. Choudhari NS; George R; Baskaran M; Vijaya L; Dudeja N Ophthalmology; 2009 Jan; 116(1):3-8. PubMed ID: 18708256 [TBL] [Abstract][Full Text] [Related]
47. Applanation tonometer tip sterilization for adenovirus type 8. Craven ER; Butler SL; McCulley JP; Luby JP Ophthalmology; 1987 Dec; 94(12):1538-40. PubMed ID: 3431823 [TBL] [Abstract][Full Text] [Related]
48. Possible modes of transmission of Creutzfeldt-Jakob disease. Davanipour Z; Goodman L; Alter M; Sobel E; Asher D; Gajdusek DC N Engl J Med; 1984 Dec; 311(24):1582-3. PubMed ID: 6390202 [No Abstract] [Full Text] [Related]
49. Minimising the risk of prion transmission by contact tonometry. Amin SZ; Smith L; Luthert PJ; Cheetham ME; Buckley RJ Br J Ophthalmol; 2003 Nov; 87(11):1360-2. PubMed ID: 14609834 [TBL] [Abstract][Full Text] [Related]
50. Tonometer tip disinfection: principles, evidence, and importance of end-user engagement in policy formulation. Arora S; Roelofs K; Damji KF Can J Ophthalmol; 2013 Jun; 48(3):136-7. PubMed ID: 23769772 [No Abstract] [Full Text] [Related]
52. [High risk in patients with Creutzfeldt-Jakob disease. Specific protective measures for the medical personnel]. Knauer RH Fortschr Med; 1999 May; 117(15):13-5. PubMed ID: 10394202 [No Abstract] [Full Text] [Related]
53. Possible modes of transmission of Creutzfeldt-Jakob disease. Tsai TF N Engl J Med; 1985 Apr; 312(14):922-3. PubMed ID: 3883180 [No Abstract] [Full Text] [Related]
54. [Handling of tissues from patients with suspected Creutzfeldt-Jakob disease. (Status 1 March 1992)]. Pfeiffer J Pathologe; 1993 Dec; 14(6):355. PubMed ID: 8121889 [No Abstract] [Full Text] [Related]
55. Viability of herpes simplex virus type 1 on the applanation tonometer. Ventura LM; Dix RD Am J Ophthalmol; 1987 Jan; 103(1):48-52. PubMed ID: 3026187 [TBL] [Abstract][Full Text] [Related]
56. Disinfection studies with two strains of mouse-passaged scrapie agent. Guidelines for Creutzfeldt-Jakob and related agents. Kimberlin RH; Walker CA; Millson GC; Taylor DM; Robertson PA; Tomlinson AH; Dickinson AG J Neurol Sci; 1983 Jun; 59(3):355-69. PubMed ID: 6308174 [TBL] [Abstract][Full Text] [Related]
57. Structural damage to Schiotz tonometers after disinfection with solutions. Chronister CL Optom Vis Sci; 1997 Mar; 74(3):164-6. PubMed ID: 9159807 [TBL] [Abstract][Full Text] [Related]
58. Disinfection of Goldmann tonometers after contamination with hepatitis C virus. Segal WA; Pirnazar JR; Arens M; Pepose JS Am J Ophthalmol; 2001 Feb; 131(2):184-7. PubMed ID: 11228293 [TBL] [Abstract][Full Text] [Related]
59. [Donor selection and preservation methods for the prevention of transmission of AIDS and Creutzfeldt-Jakob disease via allogeneic transplants in ear surgery]. Majoor MH; Meeuwsen F; Huizing EH; Veldman JE Ned Tijdschr Geneeskd; 1993 Aug; 137(34):1708-11. PubMed ID: 8371811 [No Abstract] [Full Text] [Related]