These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

457 related articles for article (PubMed ID: 11719125)

  • 21. Potential hazard of the Neopuff T-piece resuscitator in the absence of flow limitation.
    Hawkes CP; Oni OA; Dempsey EM; Ryan CA
    Arch Dis Child Fetal Neonatal Ed; 2009 Nov; 94(6):F461-3. PubMed ID: 19357121
    [TBL] [Abstract][Full Text] [Related]  

  • 22. T-piece resuscitators: how do they compare?
    Hinder M; McEwan A; Drevhammer T; Donaldson S; Tracy MB
    Arch Dis Child Fetal Neonatal Ed; 2019 Mar; 104(2):F122-F127. PubMed ID: 29728414
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Variation in inspiratory time and tidal volume with T-piece neonatal resuscitator: association with operator experience and distraction.
    McHale S; Thomas M; Hayden E; Bergin K; McCallion N; Molloy EJ
    Resuscitation; 2008 Nov; 79(2):230-3. PubMed ID: 18691802
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Reliability of Single-Use PEEP-Valves Attached to Self-Inflating Bags during Manual Ventilation of Neonates--An In Vitro Study.
    Hartung JC; Wilitzki S; Thio-Lluch M; te Pas AB; Schmalisch G; Roehr CC
    PLoS One; 2016; 11(2):e0150224. PubMed ID: 26914209
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of self-inflating bags with anesthesia bags for bag-mask ventilation in the pediatric emergency department.
    Mondolfi AA; Grenier BM; Thompson JE; Bachur RG
    Pediatr Emerg Care; 1997 Oct; 13(5):312-6. PubMed ID: 9368241
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of Simulated Ventilation Techniques With the Upright and Conventional Self-Inflating Neonatal Resuscitators.
    Narayanan I; Mendhi M; Bansil P; Coffey PS
    Respir Care; 2017 Nov; 62(11):1428-1436. PubMed ID: 28830928
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Born not breathing: A randomised trial comparing two self-inflating bag-masks during newborn resuscitation in Tanzania.
    Thallinger M; Ersdal HL; Francis F; Yeconia A; Mduma E; Kidanto H; Linde JE; Eilevstjønn J; Gunnes N; Størdal K
    Resuscitation; 2017 Jul; 116():66-72. PubMed ID: 28427883
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Equipment and operator training denote manual ventilation performance in neonatal resuscitation.
    Roehr CC; Kelm M; Proquitté H; Schmalisch G
    Am J Perinatol; 2010 Oct; 27(9):753-8. PubMed ID: 20458664
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Artificial ventilation during transport: A randomized crossover study of manual resuscitators with comparison to mechanical ventilators in a simulation model.
    Lucy MJ; Gamble JJ; Peeling A; Lam JTH; Balbuena L
    Paediatr Anaesth; 2018 Sep; 28(9):788-794. PubMed ID: 30175433
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [ProSeal™laryngeal mask in normal weight and obese patients : oxygenation under pressure-controlled ventilation and different end-expiratory pressures].
    Goldmann K; Gerlach M; Bornträger C
    Anaesthesist; 2011 Oct; 60(10):908-15. PubMed ID: 21796447
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Delivery of Positive End-Expiratory Pressure Using Self-Inflating Bags during Newborn Resuscitation Is Possible Despite Mask Leak.
    Gomo ØH; Eilevstjønn J; Holte K; Yeconia A; Kidanto H; Ersdal HL
    Neonatology; 2020; 117(3):341-348. PubMed ID: 32610333
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of the Augmented Infant Resuscitator: A Monitoring Device for Neonatal Bag-Valve-Mask Resuscitation.
    Bennett DJ; Itagaki T; Chenelle CT; Bittner EA; Kacmarek RM
    Anesth Analg; 2018 Mar; 126(3):947-955. PubMed ID: 28863023
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The effectiveness of Ambu neonatal self-inflating bag to provide consistent positive end-expiratory pressure.
    Tracy M; Shah D; Priyadarshi A; Hinder M
    Arch Dis Child Fetal Neonatal Ed; 2016 Sep; 101(5):F439-43. PubMed ID: 26785860
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Manual ventilation devices in neonatal resuscitation: tidal volume and positive pressure-provision.
    Roehr CC; Kelm M; Fischer HS; Bührer C; Schmalisch G; Proquitté H
    Resuscitation; 2010 Feb; 81(2):202-5. PubMed ID: 19926383
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Optimizing bag-valve-mask ventilation with a new mouth-to-bag resuscitator.
    Wagner-Berger HG; Wenzel V; Stallinger A; Voelckel WG; Rheinberger K; Augenstein S; Herff H; Idris AH; Dörges V; Lindner KH; Hörmann C
    Resuscitation; 2003 Feb; 56(2):191-8. PubMed ID: 12589994
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The effectiveness of nasal mask vs face mask ventilation in anesthetized, apneic pediatric subjects over 2 years of age: a randomized controlled trial.
    Itagaki T; Gubin TA; Sayal P; Jiang Y; Kacmarek RM; Anderson TA
    Paediatr Anaesth; 2016 Feb; 26(2):173-81. PubMed ID: 26725988
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Unintentional variation in positive end expiratory pressure during resuscitation with a T-piece resuscitator.
    Finer NN; Rich WD
    Resuscitation; 2011 Jun; 82(6):717-9. PubMed ID: 21481520
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Neonatal resuscitation 3: manometer use in a model of face mask ventilation.
    O'Donnell CP; Davis PG; Lau R; Dargaville PA; Doyle LW; Morley CJ
    Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F397-400. PubMed ID: 15871988
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Delivery room continuous positive airway pressure/positive end-expiratory pressure in extremely low birth weight infants: a feasibility trial.
    Finer NN; Carlo WA; Duara S; Fanaroff AA; Donovan EF; Wright LL; Kandefer S; Poole WK;
    Pediatrics; 2004 Sep; 114(3):651-7. PubMed ID: 15342835
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of manually triggered ventilation and bag-valve-mask ventilation during cardiopulmonary resuscitation in a manikin model.
    Bergrath S; Rossaint R; Biermann H; Skorning M; Beckers SK; Rörtgen D; Brokmann JCh; Flege C; Fitzner C; Czaplik M
    Resuscitation; 2012 Apr; 83(4):488-93. PubMed ID: 21958929
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 23.