1. Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation. Frazier OH; Rose EA; Oz MC; Dembitsky W; McCarthy P; Radovancevic B; Poirier VL; Dasse KA; J Thorac Cardiovasc Surg; 2001 Dec; 122(6):1186-95. PubMed ID: 11726895 [TBL] [Abstract][Full Text] [Related]
2. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy. John R; Kamdar F; Liao K; Colvin-Adams M; Boyle A; Joyce L Ann Thorac Surg; 2008 Oct; 86(4):1227-34; discussion 1234-5. PubMed ID: 18805167 [TBL] [Abstract][Full Text] [Related]
3. Post-cardiac transplant survival after support with a continuous-flow left ventricular assist device: impact of duration of left ventricular assist device support and other variables. John R; Pagani FD; Naka Y; Boyle A; Conte JV; Russell SD; Klodell CT; Milano CA; Rogers J; Farrar DJ; Frazier OH J Thorac Cardiovasc Surg; 2010 Jul; 140(1):174-81. PubMed ID: 20447659 [TBL] [Abstract][Full Text] [Related]
4. Implantable left ventricular assist device. Approaching an alternative for end-stage heart failure. Implantable LVAD Study Group. McCarthy PM; James KB; Savage RM; Vargo R; Kendall K; Harasaki H; Hobbs RE; Pashkow FJ Circulation; 1994 Nov; 90(5 Pt 2):II83-6. PubMed ID: 7955290 [TBL] [Abstract][Full Text] [Related]
5. Left ventricular assist device as bridge to transplantation does not adversely affect one-year heart transplantation survival. Cleveland JC; Grover FL; Fullerton DA; Campbell DN; Mitchell MB; Lindenfeld J; Wolfel EE; Lowes BD; Shakar SF; Brieke A; Cannon A; Robertson AD J Thorac Cardiovasc Surg; 2008 Sep; 136(3):774-7. PubMed ID: 18805284 [TBL] [Abstract][Full Text] [Related]
7. Worldwide experience with the TCI HeartMate system: issues and future perspective. Poirier VL Thorac Cardiovasc Surg; 1999 Feb; 47 Suppl 2():316-20. PubMed ID: 10218608 [TBL] [Abstract][Full Text] [Related]
8. Left ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates. Zimpfer D; Zrunek P; Roethy W; Czerny M; Schima H; Huber L; Grimm M; Rajek A; Wolner E; Wieselthaler G J Thorac Cardiovasc Surg; 2007 Mar; 133(3):689-95. PubMed ID: 17320566 [TBL] [Abstract][Full Text] [Related]
9. HeartMate VE LVAS design enhancements and its impact on device reliability. Dowling RD; Park SJ; Pagani FD; Tector AJ; Naka Y; Icenogle TB; Poirier VL; Frazier OH Eur J Cardiothorac Surg; 2004 Jun; 25(6):958-63. PubMed ID: 15144995 [TBL] [Abstract][Full Text] [Related]
10. Bridge to heart transplantation with the HeartMate device in Gothenburg, Sweden. Liden H; Wierup P; Westerberg M; Nilsson F; Wiklund L Transplant Proc; 2005 Oct; 37(8):3321-2. PubMed ID: 16298585 [TBL] [Abstract][Full Text] [Related]
11. Postcardiac transplant survival in the current era in patients receiving continuous-flow left ventricular assist devices. Kamdar F; John R; Eckman P; Colvin-Adams M; Shumway SJ; Liao K J Thorac Cardiovasc Surg; 2013 Feb; 145(2):575-81. PubMed ID: 23321132 [TBL] [Abstract][Full Text] [Related]
12. Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes. Kormos RL; Teuteberg JJ; Pagani FD; Russell SD; John R; Miller LW; Massey T; Milano CA; Moazami N; Sundareswaran KS; Farrar DJ; J Thorac Cardiovasc Surg; 2010 May; 139(5):1316-24. PubMed ID: 20132950 [TBL] [Abstract][Full Text] [Related]
13. Bridging to transplant with the HeartMate left ventricular assist device: The Columbia Presbyterian 12-year experience. Morgan JA; John R; Rao V; Weinberg AD; Lee BJ; Mazzeo PA; Flannery MR; Chen JM; Oz MC; Naka Y J Thorac Cardiovasc Surg; 2004 May; 127(5):1309-16. PubMed ID: 15115987 [TBL] [Abstract][Full Text] [Related]
14. HeartMate left ventricular assist system exchange: results and technical considerations. Adamson RM; Dembitsky WP; Baradarian S; Chammas J; Jaski B; Hoagland P; McCalmont V; Ortiz K; Stahovich M; Chillcott S ASAIO J; 2009; 55(6):598-601. PubMed ID: 19779301 [TBL] [Abstract][Full Text] [Related]
15. Improved durability of the HeartMate XVE left ventricular assist device provides safe mechanical support up to 1 year but is associated with high risk of device failure in the second year. Martin J; Friesewinkel O; Benk C; Sorg S; Schultz S; Beyersdorf F J Heart Lung Transplant; 2006 Apr; 25(4):384-90. PubMed ID: 16563965 [TBL] [Abstract][Full Text] [Related]
16. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. Pagani FD; Miller LW; Russell SD; Aaronson KD; John R; Boyle AJ; Conte JV; Bogaev RC; MacGillivray TE; Naka Y; Mancini D; Massey HT; Chen L; Klodell CT; Aranda JM; Moazami N; Ewald GA; Farrar DJ; Frazier OH; J Am Coll Cardiol; 2009 Jul; 54(4):312-21. PubMed ID: 19608028 [TBL] [Abstract][Full Text] [Related]
17. Effect of mechanical circulatory support on outcomes after heart transplantation. Drakos SG; Kfoury AG; Long JW; Stringham JC; Gilbert EM; Moore SA; Campbell BK; Nelson KE; Horne BD; Renlund DG J Heart Lung Transplant; 2006 Jan; 25(1):22-8. PubMed ID: 16399526 [TBL] [Abstract][Full Text] [Related]
18. Clinical evaluation of the HeartPak. A new pneumatic portable driver for use with the HeartMate Implantable Pneumatic Left Ventricular Assist System. Tamez D; Myers TJ; Inman RW; Miller KA; Frazier OH ASAIO J; 1997; 43(5):M797-801. PubMed ID: 9360156 [TBL] [Abstract][Full Text] [Related]
19. End-organ function in patients on long-term circulatory support with continuous- or pulsatile-flow assist devices. Radovancevic B; Vrtovec B; de Kort E; Radovancevic R; Gregoric ID; Frazier OH J Heart Lung Transplant; 2007 Aug; 26(8):815-8. PubMed ID: 17692785 [TBL] [Abstract][Full Text] [Related]
20. Results of the post-U.S. Food and Drug Administration-approval study with a continuous flow left ventricular assist device as a bridge to heart transplantation: a prospective study using the INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support). Starling RC; Naka Y; Boyle AJ; Gonzalez-Stawinski G; John R; Jorde U; Russell SD; Conte JV; Aaronson KD; McGee EC; Cotts WG; DeNofrio D; Pham DT; Farrar DJ; Pagani FD J Am Coll Cardiol; 2011 May; 57(19):1890-8. PubMed ID: 21545946 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]