These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 11740457)

  • 41. [Contribution to deep electron pendulous therapy. VIII. Communication: concerning the problem of diverging contours in telecentric electron pendulous irradiation using the electron energies 10 MeV and 20 MeV (author's transl)].
    Krause K; Hüdepohl G; Fees H; Rassow J
    Strahlentherapie; 1978 Jan; 154(1):29-37. PubMed ID: 415385
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Commissioning a p-type silicon diode for use in clinical electron beams.
    Eveling JN; Morgan AM; Pitchford WG
    Med Phys; 1999 Jan; 26(1):100-7. PubMed ID: 9949405
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Quantitative assessment of beam perturbations caused by silicon diodes used for in vivo dosimetry.
    Sen A; Parsai EI; McNeeley SW; Ayyangar KM
    Int J Radiat Oncol Biol Phys; 1996 Aug; 36(1):205-11. PubMed ID: 8823277
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Comparison of p-type commercial electron diodes for in vivo dosimetry.
    Marre D; Marinello G
    Med Phys; 2004 Jan; 31(1):50-6. PubMed ID: 14761020
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Surface dose measurements for highly oblique electron beams.
    Ostwald PM; Kron T
    Med Phys; 1996 Aug; 23(8):1413-20. PubMed ID: 8873039
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Dosimetric characteristics of a PIN diode for radiotherapy application.
    Kumar R; Sharma SD; Philomina A; Topkar A
    Technol Cancer Res Treat; 2014 Aug; 13(4):361-7. PubMed ID: 24325130
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Evaluation of P-type semiconductor diodes for in-vivo dosimetry in a 6MV x-ray beam.
    Howlett SJ; Kron T
    Australas Phys Eng Sci Med; 1996 Jun; 19(2):83-93. PubMed ID: 8826713
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Determination of electron beam mean incident energy from d50 (ionization) values.
    Ten Haken RK; Fraass BA
    Med Phys; 1987; 14(6):985-91. PubMed ID: 3696085
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Calibration of entrance dose measurement for an in vivo dosimetry programme.
    Ding W; Patterson W; Tremethick L; Joseph D
    Australas Radiol; 1995 Nov; 39(4):369-74. PubMed ID: 8561712
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Characterization of a gated fiber-optic-coupled detector for application in clinical electron beam dosimetry.
    Tanyi JA; Nitzling KD; Lodwick CJ; Huston AL; Justus BL
    Med Phys; 2011 Feb; 38(2):961-7. PubMed ID: 21452732
    [TBL] [Abstract][Full Text] [Related]  

  • 51. A linear diode array (JFD-5) for match line in vivo dosimetry in photon and electron beams; evaluation for a chest wall irradiation technique.
    Essers M; van Battum L; Heijmen BJ
    Radiother Oncol; 2001 Nov; 61(2):185-92. PubMed ID: 11690685
    [TBL] [Abstract][Full Text] [Related]  

  • 52. In vivo dosimetry: intercomparison between p-type based and n-type based diodes for the 16-25 MV energy range.
    Jornet N; Ribas M; Eudaldo T
    Med Phys; 2000 Jun; 27(6):1287-93. PubMed ID: 10902558
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Superficial dosimetry imaging of Čerenkov emission in electron beam radiotherapy of phantoms.
    Zhang R; Fox CJ; Glaser AK; Gladstone DJ; Pogue BW
    Phys Med Biol; 2013 Aug; 58(16):5477-93. PubMed ID: 23880473
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Practical approach to electron beam dosimetry at extended SSD.
    Cygler J; Li XA; Ding GX; Lawrence E
    Phys Med Biol; 1997 Aug; 42(8):1505-14. PubMed ID: 9279902
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Evaluation on the effect of dosimetry using a depth of calibration point or a depth of temporary dose maximum in high energy electron beams.].
    Haneda K; Hatakeyama N; Koyama T
    Igaku Butsuri; 2005; 25(2):59-67. PubMed ID: 16135893
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Guidelines on the implementation of diode in vivo dosimetry programs for photon and electron external beam therapy.
    Alecu R; Loomis T; Alecu J; Ochran T
    Med Dosim; 1999; 24(1):5-12. PubMed ID: 10100159
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Quality assurance by systematic in vivo dosimetry: results on a large cohort of patients.
    Fiorino C; Corletto D; Mangili P; Broggi S; Bonini A; Cattaneo GM; Parisi R; Rosso A; Signorotto P; Villa E; Calandrino R
    Radiother Oncol; 2000 Jul; 56(1):85-95. PubMed ID: 10869759
    [TBL] [Abstract][Full Text] [Related]  

  • 58. External radiation therapy boost to the vaginal vault: feasibility of intracavitary dosimetry using a commercial diode system.
    Settineri N; Pergolizzi S; Raffaele L; Maisano R; Russi EG
    Int J Radiat Oncol Biol Phys; 1999 Apr; 44(1):221-6. PubMed ID: 10219817
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Dosimetry for quality assurance in electron-beam sterilization of medical devices.
    Mehta K; Kovács A; Miller A
    Med Device Technol; 1993 May; 4(4):24-9. PubMed ID: 10148574
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Characteristics of a p-Si detector in high energy electron fields.
    Rikner G
    Acta Radiol Oncol; 1985; 24(1):71-4. PubMed ID: 2984906
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.