BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 11740754)

  • 1. Distal cement mantle thickness with a triangular distal centralizer inserted into the stem tip in cemented total hip arthroplasty.
    Kawate K; Ohmura T; Nakajima H; Takakura Y
    J Arthroplasty; 2001 Dec; 16(8):998-1003. PubMed ID: 11740754
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Total hip arthroplasty cemented femoral component distal stem centralizer. Effect on stem centralization and cement mantle.
    Hanson PB; Walker RH
    J Arthroplasty; 1995 Oct; 10(5):683-8. PubMed ID: 9273383
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dependency of cement mantle thickness on femoral stem design and centralizer.
    Breusch SJ; Lukoschek M; Kreutzer J; Brocai D; Gruen TA
    J Arthroplasty; 2001 Aug; 16(5):648-57. PubMed ID: 11503126
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of a distal centralizer on the positioning of an anatomical stem.
    Bell CA; Pilot P; van den Boogaart M; Verburg AD
    Acta Orthop Belg; 2009 Feb; 75(1):41-4. PubMed ID: 19358397
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of stem-broach sizing on the cement mantle of Lubinus SP II stems. A CT scan analysis.
    Scheerlinck T; de Mey J; Deklerck R
    Acta Orthop Belg; 2009 Jun; 75(3):346-53. PubMed ID: 19681321
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The posterior approach reduces the risk of thin cement mantles with a straight femoral stem design.
    Macpherson GJ; Hank C; Schneider M; Trayner M; Elton R; Howie CR; Breusch SJ
    Acta Orthop; 2010 Jun; 81(3):292-5. PubMed ID: 20446829
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Four-angle radiographic assessment of cement mantle thickness in cemented total hip arthroplasty.
    Kawate K; Yajima H; Tomita Y; Sugimoto K; Ohmura T; Hiyoshi N; Takakura Y
    J Arthroplasty; 2003 Oct; 18(7):914-9. PubMed ID: 14566749
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Effect of a Distal Centralizer on Cemented Femoral Stems in Arthroplasty Shown on Radiographs and SPECT/CT: A Case Report.
    Beel W; Klaeser B; Kalberer F; Meier C; Wahl P
    JBJS Case Connect; 2021 Jun; 11(2):. PubMed ID: 34101664
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Proximal and distal femoral centralizers in modern cemented hip arthroplasty.
    Goldberg BA; al-Habbal G; Noble PC; Paravic M; Liebs TR; Tullos HS
    Clin Orthop Relat Res; 1998 Apr; (349):163-73. PubMed ID: 9584379
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of stem geometry on stresses within the distal cement mantle in total hip replacement.
    Schmölz W; Gordon DR; Shields AJ; Kirkwood D; Grigoris P
    Technol Health Care; 2000; 8(1):67-73. PubMed ID: 10942992
    [TBL] [Abstract][Full Text] [Related]  

  • 11. No benefit of a proximal stem centralizer in cementing of a femoral prosthesis in human cadavers.
    Petruskevicius J; Lind-Hansen T; Aleksyniene R; Nyengaard JR; Nielsen PT; Søballe K
    Acta Orthop; 2011 Jun; 82(3):325-32. PubMed ID: 21434768
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improvement of the cement mantle of the acetabular component with bone cement spacers. A retrospective analysis of 200 cemented cups.
    Lichtinger TK; Müller RT
    Arch Orthop Trauma Surg; 1998; 118(1-2):75-7. PubMed ID: 9833111
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The bone-vacuum cementing technique for the fixation of the stem in total hip arthroplasty.
    Pitto RP; Kessler M; Schikora N; di Muria GV
    Chir Organi Mov; 2001; 86(2):99-110. PubMed ID: 12025052
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pressurization and centralization enhance the quality and reproducibility of cement mantles.
    Noble PC; Collier MB; Maltry JA; Kamaric E; Tullos HS
    Clin Orthop Relat Res; 1998 Oct; (355):77-89. PubMed ID: 9917593
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Suboptimal (thin) distal cement mantle thickness as a contributory factor in total hip arthroplasty femoral component failure. A retrospective radiographic analysis favoring distal stem centralization.
    Star MJ; Colwell CW; Kelman GJ; Ballock RT; Walker RH
    J Arthroplasty; 1994 Apr; 9(2):143-9. PubMed ID: 8014645
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Factors affecting cement strains near the tip of a cemented femoral component.
    Estok DM; Orr TE; Harris WH
    J Arthroplasty; 1997 Jan; 12(1):40-8. PubMed ID: 9021500
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radiographic analysis of a bone plug in 275 primary cemented total hip arthroplasties.
    Vanderstappen J; Simon JP; Bellemans J
    Acta Orthop Belg; 2012 Jun; 78(3):350-6. PubMed ID: 22822576
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A stem design change to reduce peak cement strains at the tip of cemented total hip arthroplasty.
    Estok DM; Harris WH
    J Arthroplasty; 2000 Aug; 15(5):584-9. PubMed ID: 10959996
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of two different types of cement restrictors on the femoral cement mantle.
    Faraj AA; Rajasekar K
    Acta Orthop Belg; 2006 Dec; 72(6):702-8. PubMed ID: 17260607
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An in-vitro investigation into the cement pressurization achieved during insertion of four different femoral stems.
    Gozzard C; Gheduzzi S; Miles AW; Learmonth ID
    Proc Inst Mech Eng H; 2005 Nov; 219(6):407-13. PubMed ID: 16312100
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.