These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

85 related articles for article (PubMed ID: 11752936)

  • 1. Contrast-enhanced magnetic resonance angiography: dose the test dose bolus represent the main dose bolus accurately?
    Lee JJ; Chang Y; Kang DS
    Korean J Radiol; 2000; 1(2):91-7. PubMed ID: 11752936
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Single-dose breath-hold gadolinium-enhanced three-dimensional MR angiography of the renal arteries.
    Lee VS; Rofsky NM; Krinsky GA; Stemerman DH; Weinreb JC
    Radiology; 1999 Apr; 211(1):69-78. PubMed ID: 10189455
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Differences in injection rates on contrast-enhanced breath-hold three-dimensional MR angiography.
    Kopka L; Vosshenrich R; Rodenwaldt J; Grabbe E
    AJR Am J Roentgenol; 1998 Feb; 170(2):345-8. PubMed ID: 9456943
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Peak contrast enhancement in CT and MR angiography: when does it occur and why? Pharmacokinetic study in a porcine model.
    Bae KT
    Radiology; 2003 Jun; 227(3):809-16. PubMed ID: 12702823
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The optimization of scan timing for contrast-enhanced magnetic resonance angiography.
    Lee JJ; Tirman PJ; Chang Y; Ryeom HK; Lee SK; Kim YS; Kang DS
    Korean J Radiol; 2000; 1(3):142-51. PubMed ID: 11752945
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Systematic analysis of the geometry of a defined contrast medium bolus--implications for contrast enhanced 3D MR-angiography of thoracic vessels].
    Kreitner KF; Kunz RP; Weschler C; Ley S; Krummenauer F; Schreiber WG; Thelen M
    Rofo; 2005 May; 177(5):646-54. PubMed ID: 15871079
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography.
    Kim JK; Farb RI; Wright GA
    Radiology; 1998 Jan; 206(1):283-9. PubMed ID: 9423685
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Arterial-phase three-dimensional contrast-enhanced MR angiography of the carotid arteries.
    Levy RA; Prince MR
    AJR Am J Roentgenol; 1996 Jul; 167(1):211-5. PubMed ID: 8659374
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Decreased venous contamination on 3D gadolinium-enhanced bolus chase peripheral mr angiography using thigh compression.
    Zhang HL; Ho BY; Chao M; Kent KC; Bush HL; Faries PL; Benvenisty AI; Prince MR
    AJR Am J Roentgenol; 2004 Oct; 183(4):1041-7. PubMed ID: 15385302
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Arterial visualization by contrast-enhanced moving-table MR angiography: crossover comparison of 0.1 and 0.2 mmol/kg doses of meglumine gadopentetate in normal volunteers.
    Hayashi H; Yuasa Y; Amano Y; Tanimoto A; Saito Y; Yoshioka K; Kita M; Kumazaki T; Hiramatsu K
    J Magn Reson Imaging; 2008 Sep; 28(3):783-90. PubMed ID: 18777556
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Gadolinium-enhanced three-dimensional MR angiography of the aorta and peripheral arteries: evaluation of a multistation examination using two gadopentetate dimeglumine infusions.
    Earls JP; Patel NH; Smith PA; DeSena S; Meissner MH
    AJR Am J Roentgenol; 1998 Sep; 171(3):599-604. PubMed ID: 9725281
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimizing of gadolinium-enhanced MR angiography by manipulation of acquisition and scan delay times.
    Lee JJ; Chang Y; Tirman PJ; Ryum HK; Lee SK; Kim YS; Kang DS
    Eur Radiol; 2001; 11(5):754-66. PubMed ID: 11372604
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Low-dose, time-resolved, contrast-enhanced 3D MR angiography in the assessment of the abdominal aorta and its major branches at 3 Tesla.
    Kramer U; Fenchel M; Laub G; Seeger A; Klumpp B; Bretschneider C; Finn JP; Claussen CD; Miller S
    Acad Radiol; 2010 May; 17(5):564-76. PubMed ID: 20171907
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of contrast dilution on contrast-enhanced MR angiography of the aorta and renal arteries.
    Laissy JP; Menegazzo D; Debray MP; Chillon S; Karila-Cohen P; Daikha A; Schouman-Claeys E
    Eur Radiol; 2001; 11(7):1198-205. PubMed ID: 11471613
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optimization of contrast timing for breath-hold three-dimensional MR angiography.
    Hany TF; McKinnon GC; Leung DA; Pfammatter T; Debatin JF
    J Magn Reson Imaging; 1997; 7(3):551-6. PubMed ID: 9170041
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 3D contrast-enhanced MR angiography of the abdominal aorta and its distal branches: Interobserver agreement of radiologists in a routine examination.
    Billaud Y; Beuf O; Desjeux G; Valette PJ; Pilleul F
    Acad Radiol; 2005 Feb; 12(2):155-63. PubMed ID: 15721592
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Results of a contrast-medium supported 3D MR-angiography in respiratory arrest following optimization of contrast medium bolus].
    Kopka L; Vosshenrich R; Müller D; Fischer U; Rodenwaldt J; Grabbe E
    Rofo; 1997 Apr; 166(4):290-5. PubMed ID: 9198491
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Low injection rate for 3D moving-table bolus-chase MR angiography: initial experience with 3-T imaging to allay venous contamination in the calf.
    Lin K; Zhang ZQ; Sun JY; Fan ZM; Lu B
    AJR Am J Roentgenol; 2008 Dec; 191(6):1734-9. PubMed ID: 19020244
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Diagnosis of renal artery stenosis with magnetic resonance angiography and stenosis quantification].
    Marchand B; Hernandez-Hoyos M; Orkisz M; Douek P
    J Mal Vasc; 2000 Dec; 25(5):312-320. PubMed ID: 11148391
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Is half-dose contrast-enhanced three-dimensional MR angiography sufficient for the abdominal aorta and pelvis?
    Takahashi S; Murakami T; Takamura M; Kim T; Hori M; Narumi Y; Nakamura H
    J Magn Reson Imaging; 2004 Feb; 19(2):194-201. PubMed ID: 14745753
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.