BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

227 related articles for article (PubMed ID: 11753008)

  • 1. Effect of ventilatory settings on accuracy of cardiac output measurement using partial CO(2) rebreathing.
    Tachibana K; Imanaka H; Miyano H; Takeuchi M; Kumon K; Nishimura M
    Anesthesiology; 2002 Jan; 96(1):96-102. PubMed ID: 11753008
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Noninvasive cardiac output measurement using partial carbon dioxide rebreathing is less accurate at settings of reduced minute ventilation and when spontaneous breathing is present.
    Tachibana K; Imanaka H; Takeuchi M; Takauchi Y; Miyano H; Nishimura M
    Anesthesiology; 2003 Apr; 98(4):830-7. PubMed ID: 12657842
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of reduced rebreathing time, in spontaneously breathing patients, on respiratory effort and accuracy in cardiac output measurement when using a partial carbon dioxide rebreathing technique: a prospective observational study.
    Tachibana K; Imanaka H; Takeuchi M; Nishida T; Takauchi Y; Nishimura M
    Crit Care; 2005 Oct; 9(5):R569-74. PubMed ID: 16277720
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulmonary capillary blood flow and cardiac output measurement by partial carbon dioxide rebreathing in patients with acute respiratory distress syndrome receiving lung protective ventilation.
    Allardet-Servent J; Forel JM; Roch A; Chiche L; Guervilly C; Bouzana F; Vincent A; Gainnier M; Loundou A; Papazian L
    Anesthesiology; 2009 Nov; 111(5):1085-92. PubMed ID: 19809287
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output.
    Haryadi DG; Orr JA; Kuck K; McJames S; Westenskow DR
    J Clin Monit Comput; 2000; 16(5-6):361-74. PubMed ID: 12580219
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Partial carbon dioxide rebreathing: a reliable technique for noninvasive measurement of nonshunted pulmonary capillary blood flow.
    de Abreu MG; Quintel M; Ragaller M; Albrecht DM
    Crit Care Med; 1997 Apr; 25(4):675-83. PubMed ID: 9142035
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison between cardiac output values measured by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury.
    Valiatti JL; Amaral JL
    Sao Paulo Med J; 2004 Nov; 122(6):233-8. PubMed ID: 15692716
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation.
    Rocco M; Spadetta G; Morelli A; Dell'Utri D; Porzi P; Conti G; Pietropaoli P
    Intensive Care Med; 2004 Jan; 30(1):82-7. PubMed ID: 14652718
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children.
    Levy RJ; Chiavacci RM; Nicolson SC; Rome JJ; Lin RJ; Helfaer MA; Nadkarni VM
    Anesth Analg; 2004 Dec; 99(6):1642-1647. PubMed ID: 15562047
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance of the partial CO2 rebreathing technique under different hemodynamic and ventilation/perfusion matching conditions.
    Gama de Abreu M; Winkler T; Pahlitzsch T; Weismann D; Albrecht DM
    Crit Care Med; 2003 Feb; 31(2):543-51. PubMed ID: 12576964
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of cardiac output before and after cardiopulmonary bypass: Comparison among aortic transit-time ultrasound, thermodilution, and noninvasive partial CO2 rebreathing.
    Botero M; Kirby D; Lobato EB; Staples ED; Gravenstein N
    J Cardiothorac Vasc Anesth; 2004 Oct; 18(5):563-72. PubMed ID: 15578466
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Noninvasive cardiac output determined with a new method based on gas exchange measurements and carbon dioxide rebreathing: a study in animals/pigs.
    Gedeon A; Krill P; Kristensen J; Gottlieb I
    J Clin Monit; 1992 Oct; 8(4):267-78. PubMed ID: 1453186
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical evaluation of a partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients.
    Odenstedt H; Stenqvist O; Lundin S
    Acta Anaesthesiol Scand; 2002 Feb; 46(2):152-9. PubMed ID: 11942862
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Non-invasive cardiac output determination: comparison of a new partial-rebreathing technique with thermodilution.
    Binder JC; Parkin WG
    Anaesth Intensive Care; 2001 Feb; 29(1):19-23. PubMed ID: 11261904
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Lack of agreement between thermodilution and carbon dioxide-rebreathing cardiac output.
    Nilsson LB; Eldrup N; Berthelsen PG
    Acta Anaesthesiol Scand; 2001 Jul; 45(6):680-5. PubMed ID: 11421824
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Partial CO(2) rebreathing technique versus thermodilution: measurement of cardiac output before and after operations with extracorporeal circulation].
    Neuhäuser C; Müller M; Bräu M; Scholz S; Böning O; Roth P; Hempelmann G
    Anaesthesist; 2002 Aug; 51(8):625-33. PubMed ID: 12391521
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated non-invasive measurement of cardiac output by the carbon dioxide rebreathing method: comparisons with dye dilution and thermodilution.
    Russell AE; Smith SA; West MJ; Aylward PE; McRitchie RJ; Hassam RM; Minson RB; Wing LM; Chalmers JP
    Br Heart J; 1990 Mar; 63(3):195-9. PubMed ID: 2109625
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model.
    Bajorat J; Hofmockel R; Vagts DA; Janda M; Pohl B; Beck C; Noeldge-Schomburg G
    Eur J Anaesthesiol; 2006 Jan; 23(1):23-30. PubMed ID: 16390561
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Non-invasive measurement of cardiac output in patients with acute lung injury using the carbon dioxide rebreathing method.
    Neviere R; Mathieu D; Riou Y; Chagnon JL; Wattel F
    Clin Intensive Care; 1994; 5(4):172-5. PubMed ID: 10150542
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Non-invasive cardiac output measurement using a fast mixing box to measure carbon dioxide elimination.
    Killick CJ; Parkin WG
    Anaesth Intensive Care; 2008 Sep; 36(5):665-73. PubMed ID: 18853584
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.