238 related articles for article (PubMed ID: 11756835)
21. Sutureless laser-welded anastomosis of the femoral artery and vein in rats using CO2 and Nd:YAG lasers.
Bürger RA; Gerharz CD; Draws J; Engelmann UH; Hohenfellner R
J Reconstr Microsurg; 1993 May; 9(3):213-8. PubMed ID: 8515400
[TBL] [Abstract][Full Text] [Related]
22. End-to-Side Microvascular Anastomosis on Rat Femoral Vessels Using Only 2-Throw Knot Interrupted Sututres - Evaluation of Feasibility and Patency Rates on Rat Femoral Vessels Model.
Pruthi N; Tyagi G; Gohil D
World Neurosurg; 2021 Apr; 148():e145-e150. PubMed ID: 33359520
[TBL] [Abstract][Full Text] [Related]
23. Effect of torsion on microvenous anastomotic patency in a rat model and early thrombolytic phenomenon.
Bilgin SS; Topalan M; Ip WY; Chow SP
Microsurgery; 2003; 23(4):381-6. PubMed ID: 12942531
[TBL] [Abstract][Full Text] [Related]
24. Effect of heparinized irrigating solutions on patency of experimental microvascular anastomoses.
Zinberg EM; Choo DI; Zotter LA
Microsurgery; 1989; 10(2):103-7; discussion 108-9. PubMed ID: 2528050
[TBL] [Abstract][Full Text] [Related]
25. The effect of prolonged clamping and vascular stasis on the patency of arterial and venous microanastomoses.
Thomson JG; Kim JH; Syed SA; Reid MA; Madsen J; Restifo RJ
Ann Plast Surg; 1998 Apr; 40(4):436-41. PubMed ID: 9556001
[TBL] [Abstract][Full Text] [Related]
26. Eversion with four sutures: an easy, fast, and reliable technique for microvascular anastomosis.
Turan T; Ozçelik D; Kuran I; Sadikoğlu B; Baş L; San T; Sungun A
Plast Reconstr Surg; 2001 Feb; 107(2):463-70. PubMed ID: 11214062
[TBL] [Abstract][Full Text] [Related]
27. Comparative study of different combinations of microvascular anastomoses in a rat model: end-to-end, end-to-side, and flow-through anastomosis.
Miyamoto S; Okazaki M; Ohura N; Shiraishi T; Takushima A; Harii K
Plast Reconstr Surg; 2008 Aug; 122(2):449-455. PubMed ID: 18626360
[TBL] [Abstract][Full Text] [Related]
28. Effect of the two-wall-stitch mistake upon patency of rat femoral vein anastomosis: Preliminary observations.
Pignatti M; Benati D; Cavadas PC
Microsurgery; 2004; 24(4):339-44. PubMed ID: 15274195
[TBL] [Abstract][Full Text] [Related]
29. Experimental prevention of free flap thrombosis. I: A model of free flap failure.
Atchabahian A; Masquelet AC
Microsurgery; 1996; 17(12):710-3. PubMed ID: 9588717
[TBL] [Abstract][Full Text] [Related]
30. Torsion is Tolerated in Arterial End to Venous Side Anastomoses in the Rat Model.
Levi MA; Harb AA; Nicolas CF; Corvi JJ; Kozato A; Akelina Y; Kadiyala RK; Strauch RJ
J Reconstr Microsurg; 2020 Sep; 36(7):501-506. PubMed ID: 32303102
[TBL] [Abstract][Full Text] [Related]
31. The value of the patency test in microvascular anastomosis: correlation between observed patency and size of intraluminal thrombus: an experimental study in rats.
Krag C; Holck S
Br J Plast Surg; 1981 Jan; 34(1):64-6. PubMed ID: 7459527
[TBL] [Abstract][Full Text] [Related]
32. In vivo microvascular freezing in veins: experimental study.
Cavadas PC; Vera-Sempere FJ
Microsurgery; 1996; 17(3):115-20. PubMed ID: 9016452
[TBL] [Abstract][Full Text] [Related]
33. Patency of anastomosed arteries and veins subjected to reapplication of microvascular clamps.
Shaffer JW; Kling TF; Wilber RG; Field GA; Williams HJ
J Hand Surg Am; 1984 Jan; 9A(1):73-5. PubMed ID: 6693748
[TBL] [Abstract][Full Text] [Related]
34. Venous microanastomosis with the Unilink system, sleeve, and suture techniques: a comparative study in the rat.
Zhang L; Kolker AR; Choe EI; Bakshandeh N; Josephson G; Wu FC; Siebert JW; Kasabian AK
J Reconstr Microsurg; 1997 May; 13(4):257-61; discussion 261-2. PubMed ID: 9144138
[TBL] [Abstract][Full Text] [Related]
35. New end-to-end microvascular anastomosis with geometrically adaptable ends technique: an experimental study on rats.
Demiralp CO; Serel S; Zeyrek T; Demirseren ME; Ergun H; Yormuk E
Bratisl Lek Listy; 2011; 112(9):483-7. PubMed ID: 21954523
[TBL] [Abstract][Full Text] [Related]
36. End-to-end versus end-to-side arterial anastomosis patency in microvascular surgery.
Dotson RJ; Bishop AT; Wood MB; Schroeder A
Microsurgery; 1998; 18(2):125-8. PubMed ID: 9674928
[TBL] [Abstract][Full Text] [Related]
37. Further technical considerations of the sleeve microanastomosis.
Kanaujia RR; Hoi KI; Miyamoto Y; Ikuta Y; Tsuge K
Plast Reconstr Surg; 1988 May; 81(5):725-34. PubMed ID: 3362988
[TBL] [Abstract][Full Text] [Related]
38. End-to-end versus end-to-side microvascular anastomosis patency in experimental venous repairs.
Bas L; May JW; Handren J; Fallon J
Plast Reconstr Surg; 1986 Mar; 77(3):442-50. PubMed ID: 3952200
[TBL] [Abstract][Full Text] [Related]
39. Mechanical evaluation of anastomotic tension and patency in arteries.
Zhang F; Lineaweaver WC; Buntic R; Walker R
J Reconstr Microsurg; 1996 Feb; 12(2):121-6. PubMed ID: 8656400
[TBL] [Abstract][Full Text] [Related]
40. Introduction of loop sutures in microsurgical telescoping anastomosis.
Saitoh S; Nakatsuchi Y
Br J Plast Surg; 1993 Mar; 46(2):105-9. PubMed ID: 8461897
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]