These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

256 related articles for article (PubMed ID: 11759100)

  • 1. Microleakage of three sealants following conventional, bur, and air-abrasion preparation of pits and fissures.
    Hatibovic-Kofman S; Butler SA; Sadek H
    Int J Paediatr Dent; 2001 Nov; 11(6):409-16. PubMed ID: 11759100
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microleakage of sealants after conventional, bur, and air-abrasion preparation of pits and fissures.
    Hatibovic-Kofman S; Wright GZ; Braverman I
    Pediatr Dent; 1998; 20(3):173-6. PubMed ID: 9635312
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of six different methods of cleaning and preparing occlusal fissure surface before placement of pit and fissure sealant: an in vitro study.
    Agrawal A; Shigli A
    J Indian Soc Pedod Prev Dent; 2012; 30(1):51-5. PubMed ID: 22565518
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microleakage of a pit-and-fissure sealant: effect of air-abrasion compared with classical enamel preparations.
    Lupi-Pégurier L; Muller-Bolla M; Bertrand MF; Fradet T; Bolla M
    J Adhes Dent; 2004; 6(1):43-8. PubMed ID: 15119586
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance of a conventional sealant and a flowable composite on minimally invasive prepared fissures.
    Francescut P; Lussi A
    Oper Dent; 2006; 31(5):543-50. PubMed ID: 17024941
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Microleakage evaluation of a flowable polyacid-modified resin composite used as fissure sealant on air-abraded permanent teeth.
    Güngör HC; Turgut MD; Attar N; Altay N
    Oper Dent; 2003; 28(3):267-73. PubMed ID: 12760698
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of laser and air abrasion pretreatment on the microleakage of a fissure sealant applied with conventional and self etch adhesives.
    Tirali RE; Celik C; Arhun N; Berk G; Cehreli SB
    J Clin Pediatr Dent; 2013; 37(3):281-8. PubMed ID: 23855173
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Marginal seal of sealant and compomer materials with and without enameloplasty.
    Salama FS; Al-Hammad NS
    Int J Paediatr Dent; 2002 Jan; 12(1):39-46. PubMed ID: 11853247
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Degree of microleakage of a self-etch sealant.
    Conner FA; Vandewalle KS; Bartoloni JA
    Gen Dent; 2011; 59(3):224-8. PubMed ID: 21903546
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Preparation for invasive pit and fissure sealing: air-abrasion or bur?
    Kramer N; García-Godoy F; Lohbauer U; Schneider K; Assmann I; Frankenberger R
    Am J Dent; 2008 Dec; 21(6):383-7. PubMed ID: 19146132
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of tooth preparation on microleakage behavior.
    von Fraunhofer JA; Adachi EI; Barnes DM; Romberg E
    Oper Dent; 2000; 25(6):526-33. PubMed ID: 11203866
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Microleakage of compomer restorations in primary teeth after preparation with bur or air abrasion.
    Aysegül O; Nurhan O; Haluk B; Dilek T
    Oper Dent; 2005; 30(2):164-9. PubMed ID: 15853100
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of pumice, fissure enameloplasty and air abrasion on sealant microleakage.
    Blackwood JA; Dilley DC; Roberts MW; Swift EJ
    Pediatr Dent; 2002; 24(3):199-203. PubMed ID: 12064490
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microleakage and sealant penetration in contaminated carious fissures.
    Hevinga MA; Opdam NJ; Frencken JE; Bronkhorst EM; Truin GJ
    J Dent; 2007 Dec; 35(12):909-14. PubMed ID: 17961903
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microleakage and bond strength of sealant to primary enamel comparing air abrasion and acid etch techniques.
    Knobloch LA; Meyer T; Kerby RE; Johnston W
    Pediatr Dent; 2005; 27(6):463-9. PubMed ID: 16532886
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microleakage of self-etching sealant on noncontaminated and saliva-contaminated enamel.
    ; ; ;
    Pediatr Dent; 2011; 33(7):479-83. PubMed ID: 22353406
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Microleakage and penetration of a hydrophilic sealant and a conventional resin-based sealant as a function of preparation techniques: a laboratory study.
    Khogli AE; Cauwels R; Vercruysse C; Verbeeck R; Martens L
    Int J Paediatr Dent; 2013 Jan; 23(1):13-22. PubMed ID: 22276649
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro study of microleakage of different techniques of surface preparation used in pits and fissures.
    Javadinejad S; Razavi M; Birang R; Atefat M
    Indian J Dent Res; 2012; 23(2):247-50. PubMed ID: 22945718
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In-vitro microleakage of repaired fissure sealants: a randomized, controlled trial.
    Srinivasan V; Deery C; Nugent Z
    Int J Paediatr Dent; 2005 Jan; 15(1):51-60. PubMed ID: 15663445
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Resin-based pit-and-fissure sealants: microleakage reduction and infiltration enhancement using a bonding agent.
    Meller C; Reichenmiller K; Schwahn C; Samietz S; Blunck U
    J Adhes Dent; 2015 Feb; 17(1):59-65. PubMed ID: 25625135
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.