These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 11764039)

  • 1. A fast and efficient method for sequential cone-beam tomography.
    Köhler TH; Proksa R; Grass M
    Med Phys; 2001 Nov; 28(11):2318-27. PubMed ID: 11764039
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory.
    Tang X; Hsieh J; Hagiwara A; Nilsen RA; Thibault JB; Drapkin E
    Phys Med Biol; 2005 Aug; 50(16):3889-905. PubMed ID: 16077234
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accurate technique for complete geometric calibration of cone-beam computed tomography systems.
    Cho Y; Moseley DJ; Siewerdsen JH; Jaffray DA
    Med Phys; 2005 Apr; 32(4):968-83. PubMed ID: 15895580
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A general exact method for synthesizing parallel-beam projections from cone-beam projections via filtered backprojection.
    Li L; Chen Z; Xing Y; Zhang L; Kang K; Wang G
    Phys Med Biol; 2006 Nov; 51(21):5643-54. PubMed ID: 17047275
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A curve-filtered FDK (C-FDK) reconstruction algorithm for circular cone-beam CT.
    Li L; Xing Y; Chen Z; Zhang L; Kang K
    J Xray Sci Technol; 2011; 19(3):355-71. PubMed ID: 21876285
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Angular weighted hybrid cone-beam CT reconstruction for circular trajectories.
    Grass M; Köhler T; Proksa R
    Phys Med Biol; 2001 Jun; 46(6):1595-610. PubMed ID: 11419621
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An approximate short scan helical FDK cone beam algorithm based on nutating curved surfaces satisfying the Tuy's condition.
    Hu J; Tam K; Qi J
    Med Phys; 2005 Jun; 32(6):1529-36. PubMed ID: 16013710
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reciprocal-FDK reconstruction for x-ray diffraction computed tomography.
    Liang K; Zhang L; Xing Y
    Phys Med Biol; 2022 Apr; 67(9):. PubMed ID: 35263726
    [No Abstract]   [Full Text] [Related]  

  • 9. A new scheme and reconstruction algorithm for dual source circular CT.
    Yan M; Zhang C; Liang H
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():3783-6. PubMed ID: 17945797
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Exact (spiral + circles) scan region-of-interest cone beam reconstruction via backprojection.
    Tam KC; Lauritsch G; Sourbelle K; Sauer F; Ladendorf B
    IEEE Trans Med Imaging; 2000 May; 19(5):376-83. PubMed ID: 11021681
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Studies on circular isocentric cone-beam trajectories for 3D image reconstructions using FDK algorithm.
    Soimu D; Buliev I; Pallikarakis N
    Comput Med Imaging Graph; 2008 Apr; 32(3):210-20. PubMed ID: 18255264
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cone-beam mammo-computed tomography from data along two tilting arcs.
    Zeng K; Yu H; Fajardo LL; Wang G
    Med Phys; 2006 Oct; 33(10):3621-33. PubMed ID: 17089827
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The n-PI-method for helical cone-beam CT.
    Proksa R; Köhler T; Grass M; Timmer J
    IEEE Trans Med Imaging; 2000 Sep; 19(9):848-63. PubMed ID: 11127600
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Chord-based image reconstruction in cone-beam CT with a curved detector.
    Zuo N; Xia D; Zou Y; Jiang T; Pan XC
    Med Phys; 2006 Oct; 33(10):3743-57. PubMed ID: 17089840
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A cone-beam reconstruction algorithm for circle-plus-arc data-acquisition geometry.
    Wang X; Ning R
    IEEE Trans Med Imaging; 1999 Sep; 18(9):815-24. PubMed ID: 10571386
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tilted plane Feldkamp type reconstruction algorithm for spiral cone beam CT.
    Yan M; Zhang C
    Med Phys; 2005 Nov; 32(11):3455-67. PubMed ID: 16370432
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: preliminary phantom study.
    Ning R; Tang X; Conover D; Yu R
    Med Phys; 2003 Jul; 30(7):1694-705. PubMed ID: 12906186
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cardiac cone-beam CT volume reconstruction using ART.
    Nielsen T; Manzke R; Proksa R; Grass M
    Med Phys; 2005 Apr; 32(4):851-60. PubMed ID: 15895567
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of a cone angle weighted three-dimensional image reconstruction algorithm to reduce cone-beam artefacts.
    Gomi T; Koshida K; Miyati T
    Dentomaxillofac Radiol; 2006 Nov; 35(6):398-406. PubMed ID: 17082329
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Temporal resolution and the evaluation of candidate algorithms for four-dimensional CT.
    Taguchi K
    Med Phys; 2003 Apr; 30(4):640-50. PubMed ID: 12722816
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.