133 related articles for article (PubMed ID: 11765783)
1. Chemiluminescence flow sensor for folic acid with immobilized reagents.
Song Z; Zhou X
Spectrochim Acta A Mol Biomol Spectrosc; 2001 Nov; 57(13):2567-74. PubMed ID: 11765783
[TBL] [Abstract][Full Text] [Related]
2. Chemiluminescence flow sensor for berberine with immobilized reagents.
Song Z; Zhao T; Wang L; Xiao Z
Bioorg Med Chem; 2001 Jul; 9(7):1701-5. PubMed ID: 11425570
[TBL] [Abstract][Full Text] [Related]
3. Determination of picomole amounts of thiamine through flow-injection analysis based on the suppression of luminol-KIO(4) chemiluminescence system.
Song Z; Hou S
J Pharm Biomed Anal; 2002 May; 28(3-4):683-91. PubMed ID: 12008148
[TBL] [Abstract][Full Text] [Related]
4. Chemiluminescence flow-through sensor for the determination of vitamin B2 using controlled-reagent-release technology.
Wang L; Song ZH
Yao Xue Xue Bao; 2002 Oct; 37(10):793-7. PubMed ID: 12567864
[TBL] [Abstract][Full Text] [Related]
5. Cetyltrimethylammonium bromide-enhanced chemiluminescence determination of uric acid using a luminol-hexacyanoferrate(III)-hexacyanoferrate(II) system.
Han S; Liu E; Li H
Anal Sci; 2005 Feb; 21(2):111-4. PubMed ID: 15732468
[TBL] [Abstract][Full Text] [Related]
6. In vitro monitoring sub-nanogram amounts analgin in human urine by its inhibitory of the luminol-periodate chemiluminescence reaction using reagent immobilization release technique.
Song Z; Zhang N
Bioorg Med Chem; 2002 Jul; 10(7):2091-7. PubMed ID: 11983504
[TBL] [Abstract][Full Text] [Related]
7. Chemiluminescence investigation of detection of rutin in medicine and human urine using controlled-reagent-release technology.
Song Z; Wang L
J Agric Food Chem; 2001 Dec; 49(12):5697-701. PubMed ID: 11743749
[TBL] [Abstract][Full Text] [Related]
8. Chemiluminescence flow sensor with immobilized reagent for the determination of pyrogallol based on potassium hexacyanoferrate(III) oxidation.
Chen J; Bai J
Spectrochim Acta A Mol Biomol Spectrosc; 2008 Dec; 71(3):989-92. PubMed ID: 18373950
[TBL] [Abstract][Full Text] [Related]
9. A new potassium tetrabromoaurate (III)-luminol chemiluminescence system for the determination of folic acid in milk powder.
Zhao S; Zhang P; Liang X; Hua D; Ma T; Pei G
J Food Sci; 2012 Jan; 77(1):C102-6. PubMed ID: 22260098
[TBL] [Abstract][Full Text] [Related]
10. Chemiluminescence sensor for isoniazid with controlled-reagent-release technology.
Song Z; Lü J; Zhao T
Talanta; 2001 Mar; 53(6):1171-7. PubMed ID: 18968210
[TBL] [Abstract][Full Text] [Related]
11. Chemiluminescence inhibition assay for folic acid using flow injection analysis.
Song Z; Wang L
Phytochem Anal; 2003; 14(4):216-20. PubMed ID: 12892416
[TBL] [Abstract][Full Text] [Related]
12. Chemiluminescence flow sensor for the determination of ascorbic acid with immobilized reagents.
Zhang Z; Qin W
Talanta; 1996 Jan; 43(1):119-24. PubMed ID: 18966471
[TBL] [Abstract][Full Text] [Related]
13. A new green analytical procedure for monitoring sub-nanogram amounts of chlorpyrifos on fruits using flow injection chemiluminescence with immobilized reagents.
Song Z; Hou S; Zhang N
J Agric Food Chem; 2002 Jul; 50(16):4468-74. PubMed ID: 12137462
[TBL] [Abstract][Full Text] [Related]
14. Flow-injection inhibition chemiluminescence determination of indapamide based on luminol-ferricyanide reaction.
Wang Z; Zhang Z; Zhang X; Fu Z
J Pharm Biomed Anal; 2004 Apr; 35(1):1-7. PubMed ID: 15030874
[TBL] [Abstract][Full Text] [Related]
15. Determination of dopamine by flow-injection analysis coupled with luminol-hexacyanoferrate(III) chemiluminescence detection.
Nalewajko E; Bort Ramírez R; Kojło A
J Pharm Biomed Anal; 2004 Sep; 36(1):219-23. PubMed ID: 15351069
[TBL] [Abstract][Full Text] [Related]
16. Chemiluminescence flow-through sensor for copper based on an anodic stripping voltammetric flow cell and an ion-exchange column with immobilized reagents.
Qin W; Zhang Z; Liu H
Anal Chem; 1998 Sep; 70(17):3579-84. PubMed ID: 9737209
[TBL] [Abstract][Full Text] [Related]
17. Chemiluminescence assay for uric acid in human serum and urine using flow-injection with immobilized reagents technology.
Song ZH; Hou S
Anal Bioanal Chem; 2002 Jan; 372(2):327-32. PubMed ID: 11936107
[TBL] [Abstract][Full Text] [Related]
18. Flow injection chemiluminescence determination of 2-methoxyestradiol based on inhibition of luminol-potassium ferricyanide reaction.
Jin J; Yao H; Chen Z; Pang L; Du B
Luminescence; 2013; 28(3):270-4. PubMed ID: 22522659
[TBL] [Abstract][Full Text] [Related]
19. Chemiluminescence flow system for vanadium(v) with immobilized reagents.
Qin W; Zhang Z; Zhang C
Analyst; 1997 Jul; 122(7):685-8. PubMed ID: 9330039
[TBL] [Abstract][Full Text] [Related]
20. Flow-injection determination of ornidazole by chemiluminescence detection based on a luminol-ferricyanide reaction.
Lv Y; Zhang Z; He D; Hu Y
Anal Sci; 2003 Apr; 19(4):625-7. PubMed ID: 12725405
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]