3. Echo time dependence of BOLD fMRI studies of the piriform cortex. Kopietz R; Albrecht J; Linn J; Pollatos O; Anzinger A; Wesemann T; Fesl G; Stephan T; Brückmann H; Wiesmann M Klin Neuroradiol; 2009 Dec; 19(4):275-82. PubMed ID: 19936572 [TBL] [Abstract][Full Text] [Related]
4. Characterizing contrast origins and noise contribution in spin-echo EPI BOLD at 3 T. Ragot DM; Chen JJ Magn Reson Imaging; 2019 Apr; 57():328-336. PubMed ID: 30439514 [TBL] [Abstract][Full Text] [Related]
5. BOLD sensitivity and SNR characteristics of parallel imaging-accelerated single-shot multi-echo EPI for fMRI. Bhavsar S; Zvyagintsev M; Mathiak K Neuroimage; 2014 Jan; 84():65-75. PubMed ID: 23954488 [TBL] [Abstract][Full Text] [Related]
6. Regional differences in the refractory period of the hemodynamic response: an event-related fMRI study. Huettel SA; McCarthy G Neuroimage; 2001 Nov; 14(5):967-76. PubMed ID: 11697929 [TBL] [Abstract][Full Text] [Related]
7. Improved BOLD detection in the medial temporal region using parallel imaging and voxel volume reduction. Bellgowan PS; Bandettini PA; van Gelderen P; Martin A; Bodurka J Neuroimage; 2006 Feb; 29(4):1244-51. PubMed ID: 16242347 [TBL] [Abstract][Full Text] [Related]
10. BOLD signal in memory paradigms in hippocampal region depends on echo time. Milian M; Zeltner L; Klamer S; Klose U; Rona S; Erb M J Magn Reson Imaging; 2013 May; 37(5):1064-71. PubMed ID: 23124612 [TBL] [Abstract][Full Text] [Related]
11. An equal-TE ultrafast 3D gradient-echo imaging method with high tolerance to magnetic susceptibility artifacts: Application to BOLD functional MRI. Ryu JK; Jung WB; Yu J; Son JP; Lee SK; Kim SG; Park JY Magn Reson Med; 2021 Apr; 85(4):1986-2000. PubMed ID: 33107102 [TBL] [Abstract][Full Text] [Related]
12. Single-shot T(2)* mapping with 3D compensation of local susceptibility gradients in multiple regions. Posse S; Shen Z; Kiselev V; Kemna LJ Neuroimage; 2003 Feb; 18(2):390-400. PubMed ID: 12595192 [TBL] [Abstract][Full Text] [Related]
13. Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI. Kundu P; Inati SJ; Evans JW; Luh WM; Bandettini PA Neuroimage; 2012 Apr; 60(3):1759-70. PubMed ID: 22209809 [TBL] [Abstract][Full Text] [Related]
14. Reduction of susceptibility-induced signal losses in multi-gradient-echo images: application to improved visualization of the subthalamic nucleus. Volz S; Hattingen E; Preibisch C; Gasser T; Deichmann R Neuroimage; 2009 May; 45(4):1135-43. PubMed ID: 19349229 [TBL] [Abstract][Full Text] [Related]
15. Spatial sensitivity and temporal response of spin echo and gradient echo bold contrast at 3 T using peak hemodynamic activation time. Hulvershorn J; Bloy L; Gualtieri EE; Leigh JS; Elliott MA Neuroimage; 2005 Jan; 24(1):216-23. PubMed ID: 15588613 [TBL] [Abstract][Full Text] [Related]
16. The Impact of Echo Time Shifts and Temporal Signal Fluctuations on BOLD Sensitivity in Presurgical Planning at 7 T. Dymerska B; De Lima Cardoso P; Bachrata B; Fischmeister F; Matt E; Beisteiner R; Trattnig S; Robinson SD Invest Radiol; 2019 Jun; 54(6):340-348. PubMed ID: 30724813 [TBL] [Abstract][Full Text] [Related]
17. A comparison of dual gradient-echo and spin-echo fMRI of the inferior temporal lobe. Halai AD; Welbourne SR; Embleton K; Parkes LM Hum Brain Mapp; 2014 Aug; 35(8):4118-28. PubMed ID: 24677506 [TBL] [Abstract][Full Text] [Related]
18. Dual echo EPI--the method of choice for fMRI in the presence of magnetic field inhomogeneities? Schwarzbauer C; Mildner T; Heinke W; Brett M; Deichmann R Neuroimage; 2010 Jan; 49(1):316-26. PubMed ID: 19699805 [TBL] [Abstract][Full Text] [Related]
19. Parallel imaging with asymmetric acceleration to reduce Gibbs artifacts and to increase signal-to-noise ratio of the gradient echo echo-planar imaging sequence for functional MRI. Jung KJ; Zhao T Magn Reson Med; 2012 Feb; 67(2):419-27. PubMed ID: 21713976 [TBL] [Abstract][Full Text] [Related]
20. Optimized EPI for fMRI studies of the orbitofrontal cortex. Deichmann R; Gottfried JA; Hutton C; Turner R Neuroimage; 2003 Jun; 19(2 Pt 1):430-41. PubMed ID: 12814592 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]