These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 11786362)

  • 1. Stabilization of ferrocene leakage by physical retention in a cellulose acetate membrane. The fructose biosensor.
    Tkác J; Vostiar I; Gemeiner P; Sturdík E
    Bioelectrochemistry; 2002 Jan; 55(1-2):149-51. PubMed ID: 11786362
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ferrocene-Mediated carbon paste electrode modified with D-fructose dehydrogenase for batch mode measurement of D-fructose.
    Boujtita M; El Murr N
    Appl Biochem Biotechnol; 2000 Oct; 89(1):55-66. PubMed ID: 11069008
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of a platinized and ferrocene-mediated cholesterol amperometric biosensor based on electropolymerization of polypyrrole in a flow system.
    Vidal JC; Garcia E; Castillo JR
    Anal Sci; 2002 May; 18(5):537-42. PubMed ID: 12036121
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Enhanced Signal Amplification in a Toll-like Receptor-4 Biosensor Utilizing Ferrocene-Terminated Mixed Monolayers.
    Mayall RM; Renaud-Young M; Gawron E; Luong S; Creager S; Birss VI
    ACS Sens; 2019 Jan; 4(1):143-151. PubMed ID: 30562004
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Immobilization of cholesterol oxidase on cellulose acetate membrane for free cholesterol biosensor development.
    Wang S; Li S; Yu Y
    Artif Cells Blood Substit Immobil Biotechnol; 2004; 32(3):413-25. PubMed ID: 15508278
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An amperometric biosensor utilizing a ferrocene-mediated horseradish peroxidase reaction for the determination of capsaicin (chili hotness).
    Mohammad R; Ahmad M; Heng LY
    Sensors (Basel); 2013 Aug; 13(8):10014-26. PubMed ID: 23921830
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Immobilization of Glucose Oxidase on a Carbon Nanotubes/Dendrimer-Ferrocene Modified Electrode for Reagentless Glucose Biosensing.
    Zhou J; Li H; Yang H; Cheng H; Lai G
    J Nanosci Nanotechnol; 2017 Jan; 17(1):212-16. PubMed ID: 29617103
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ferrocene-functionalized graphene electrode for biosensing applications.
    Rabti A; Mayorga-Martinez CC; Baptista-Pires L; Raouafi N; Merkoçi A
    Anal Chim Acta; 2016 Jul; 926():28-35. PubMed ID: 27216390
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ferrocene branched chitosan for the construction of a reagentless amperometric hydrogen peroxide biosensor.
    Garcia A; Peniche-Covas C; Chico B; Simpson BK; Villalonga R
    Macromol Biosci; 2007 Apr; 7(4):435-9. PubMed ID: 17429804
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Amperometric glucose biosensor based on a gold nanorods/cellulose acetate composite film as immobilization matrix.
    Ren X; Chen D; Meng X; Tang F; Du A; Zhang L
    Colloids Surf B Biointerfaces; 2009 Sep; 72(2):188-92. PubMed ID: 19414241
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Study of cellulose acetate membrane-based glucose biosensors.
    Wang S; Ji X; Yuan Z
    Chin J Biotechnol; 1995; 11(3):199-205. PubMed ID: 8679937
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Construction of ferrocene modified conducting polymer based amperometric urea biosensor.
    Dervisevic M; Dervisevic E; Senel M; Cevik E; Yildiz HB; Camurlu P
    Enzyme Microb Technol; 2017 Jul; 102():53-59. PubMed ID: 28465061
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Highly sensitive and selective dopamine biosensor based on a phenylethynyl ferrocene/graphene nanocomposite modified electrode.
    Liu M; Wang L; Deng J; Chen Q; Li Y; Zhang Y; Li H; Yao S
    Analyst; 2012 Oct; 137(19):4577-83. PubMed ID: 22900263
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The electrochemical behaviour of ferrocene in a photocurable poly(methyl methacrylate-co-2-hydroxylethyl methacrylate) film for a glucose biosensor.
    Bean LS; Heng LY; Yamin BM; Ahmad M
    Bioelectrochemistry; 2005 Feb; 65(2):157-62. PubMed ID: 15713567
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ferrocene-Modified Linear Poly(ethylenimine) for Enzymatic Immobilization and Electron Mediation.
    Hickey DP
    Methods Mol Biol; 2017; 1504():181-191. PubMed ID: 27770422
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Studies on the electrochemical performance of glucose biosensor based on ferrocene encapsulated ORMOSIL and glucose oxidase modified graphite paste electrode.
    Pandey PC; Upadhyay S; Shukla NK; Sharma S
    Biosens Bioelectron; 2003 Sep; 18(10):1257-68. PubMed ID: 12835044
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel amperometric alcohol biosensor developed in a 3rd generation bioelectrode platform using peroxidase coupled ferrocene activated alcohol oxidase as biorecognition system.
    Chinnadayyala SR; Kakoti A; Santhosh M; Goswami P
    Biosens Bioelectron; 2014 May; 55():120-6. PubMed ID: 24368229
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reduced graphene oxide doping with nanometer-sized ferrocene moieties - New active material for glucose redox sensors.
    Matysiak-Brynda E; Sęk JP; Kasprzak A; Królikowska A; Donten M; Patrzalek M; Poplawska M; Nowicka AM
    Biosens Bioelectron; 2019 Mar; 128():23-31. PubMed ID: 30616214
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electrochemical biosensing platform using hydrogel prepared from ferrocene modified amino acid as highly efficient immobilization matrix.
    Qu F; Zhang Y; Rasooly A; Yang M
    Anal Chem; 2014 Jan; 86(2):973-6. PubMed ID: 24383679
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ferrocene-decorated nanocrystalline cellulose with charge carrier mobility.
    Eyley S; Shariki S; Dale SE; Bending S; Marken F; Thielemans W
    Langmuir; 2012 Apr; 28(16):6514-9. PubMed ID: 22486421
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.