BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 11793295)

  • 1. [Reduction of radiation exposure by using storage phosphor radiography on pelvis and lumbar spine].
    Heyne JP; Sehner J; Neumann R; Werner B; Adler R; Freesmeyer M; Kaiser WA
    Rofo; 2002 Jan; 174(1):104-11. PubMed ID: 11793295
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [The reduction of the radiation dosage by means of storage phosphor-film radiography compared to a conventional film-screen system with a grid cassette on a skull phantom].
    Heyne JP; Merbold H; Sehner J; Neumann R; Freesmeyer M; Jonetz-Mentzel L; Kaiser WA
    Rofo; 1999 Jul; 171(1):54-9. PubMed ID: 10464506
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Reduction of radiation dosage by using digital luminescence radiography on a hand phantom].
    Heyne JP; Merbold H; Sehner J; Neumann R; Adler R; Freesmeyer M; Kaiser WA
    Rofo; 2000 Apr; 172(4):386-90. PubMed ID: 10961225
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Lumbar spine radiography: digital flat-panel detector versus screen-film and storage-phosphor systems in monkeys as a pediatric model.
    Ludwig K; Ahlers K; Wormanns D; Freund M; Bernhardt TM; Diederich S; Heindel W
    Radiology; 2003 Oct; 229(1):140-4. PubMed ID: 12925714
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dose optimisation in computed radiography.
    Schreiner-Karoussou A
    Radiat Prot Dosimetry; 2005; 117(1-3):139-42. PubMed ID: 16461522
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automatic exposure control calibration and optimisation for abdomen, pelvis and lumbar spine imaging with an Agfa computed radiography system.
    Moore CS; Wood TJ; Avery G; Balcam S; Needler L; Joshi H; Saunderson JR; Beavis AW
    Phys Med Biol; 2016 Nov; 61(21):N551-N564. PubMed ID: 27716642
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Varied tube potential with constant effective dose at lumbar spine radiography using a flat-panel digital detector.
    Geijer H; Persliden J
    Radiat Prot Dosimetry; 2005; 114(1-3):240-5. PubMed ID: 15933115
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Image quality and exposure dose in digital projection radiography].
    Busch HP; Busch S; Decker C; Schilz C
    Rofo; 2003 Jan; 175(1):32-7. PubMed ID: 12525978
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Radiation doses and image information in digital pelvimetry with a phosphorous screen.
    Holje G; Jarlman O; Samuelsson L
    Acta Radiol; 1997 Jan; 38(1):181-4. PubMed ID: 9059425
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Digital radiography in paediatrics: radiation dose considerations and magnitude of possible dose reduction.
    Hufton AP; Doyle SM; Carty HM
    Br J Radiol; 1998 Feb; 71(842):186-99. PubMed ID: 9579183
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimisation of image plate radiography with respect to tube voltage.
    Tingberg A; Sjöström D
    Radiat Prot Dosimetry; 2005; 114(1-3):286-93. PubMed ID: 15933123
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Does digital imaging decrease patient dose? A pilot study and review of the literature.
    Neofotistou V; Tsapaki V; Kottou S; Schreiner-Karoussou A; Vano E
    Radiat Prot Dosimetry; 2005; 117(1-3):204-10. PubMed ID: 16464833
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Screen-film versus digital radiography of sacroiliac joints: evaluation of image quality and dose to patients.
    Jablanovic D; Ciraj-Bjelac O; Damjanov N; Seric S; Radak-Perovic M; Arandjic D; Maksimovic R
    Radiat Prot Dosimetry; 2013 Jun; 155(1):88-95. PubMed ID: 23185070
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimizing the tube potential for lumbar spine radiography with a flat-panel digital detector.
    Geijer H; Norrman E; Persliden J
    Br J Radiol; 2009 Jan; 82(973):62-8. PubMed ID: 19095816
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Initial clinical results with a new needle screen storage phosphor system in chest radiograms.
    Körner M; Wirth S; Treitl M; Reiser M; Pfeifer KJ
    Rofo; 2005 Nov; 177(11):1491-6. PubMed ID: 16302129
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dose reduction in patients undergoing chest imaging: digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography.
    Bacher K; Smeets P; Bonnarens K; De Hauwere A; Verstraete K; Thierens H
    AJR Am J Roentgenol; 2003 Oct; 181(4):923-9. PubMed ID: 14500203
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimising automatic exposure control in computed radiography and the impact on patient dose.
    Doyle P; Gentle D; Martin CJ
    Radiat Prot Dosimetry; 2005; 114(1-3):236-9. PubMed ID: 15933114
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does a combination of dose modulation with fast gantry rotation time limit CT image quality?
    Israel GM; Herlihy S; Rubinowitz AN; Cornfeld D; Brink J
    AJR Am J Roentgenol; 2008 Jul; 191(1):140-4. PubMed ID: 18562737
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A study and optimization of lumbar spine X-ray imaging systems.
    McVey G; Sandborg M; Dance DR; Alm Carlsson G
    Br J Radiol; 2003 Mar; 76(903):177-88. PubMed ID: 12684233
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quality of digital pre-implant tomography: comparison of film-screen images with storage phosphor images at normal and low dose.
    Ekestubbe A; Gröndahl HG; Molander B
    Dentomaxillofac Radiol; 2003 Sep; 32(5):322-6. PubMed ID: 14709608
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.