  • 1. A Monte Carlo study of radiation transport through multileaf collimators.
    Kim JO; Siebers JV; Keall PJ; Arnfield MR; Mohan R
    Med Phys; 2001 Dec; 28(12):2497-506. PubMed ID: 11797953
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A method for photon beam Monte Carlo multileaf collimator particle transport.
    Siebers JV; Keall PJ; Kim JO; Mohan R
    Phys Med Biol; 2002 Sep; 47(17):3225-49. PubMed ID: 12361220
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monte Carlo implementation, validation, and characterization of a 120 leaf MLC.
    Fix MK; Volken W; Frei D; Frauchiger D; Born EJ; Manser P
    Med Phys; 2011 Oct; 38(10):5311-20. PubMed ID: 21992349
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy.
    Arnfield MR; Siebers JV; Kim JO; Wu Q; Keall PJ; Mohan R
    Med Phys; 2000 Oct; 27(10):2231-41. PubMed ID: 11099190
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimizing the MLC model parameters for IMRT in the RayStation treatment planning system.
    Chen S; Yi BY; Yang X; Xu H; Prado KL; D'Souza WD
    J Appl Clin Med Phys; 2015 Sep; 16(5):322–332. PubMed ID: 26699315
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and commissioning of a multileaf collimator model in monte carlo dose calculations for intensity-modulated radiation therapy.
    Jang SY; Vassiliev ON; Liu HH; Mohan R; Siebers JV
    Med Phys; 2006 Mar; 33(3):770-81. PubMed ID: 16878579
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number.
    Zygmanski P; Kung JH; Jiang SB; Chin L
    Med Phys; 2003 Oct; 30(10):2736-49. PubMed ID: 14596312
    [TBL] [Abstract][Full Text] [Related]  

  • 8. 6 MV dosimetric characterization of the 160 MLC, the new Siemens multileaf collimator.
    Tacke MB; Nill S; Häring P; Oelfke U
    Med Phys; 2008 May; 35(5):1634-42. PubMed ID: 18561638
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo simulation based study of a proposed multileaf collimator for a telecobalt machine.
    Sahani G; Dutt Sharma S; Dash Sharma PK; Sharma DN; Hussain SA
    Med Phys; 2013 Feb; 40(2):021705. PubMed ID: 23387728
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation.
    Mihaylov IB; Lerma FA; Wu Y; Siebers JV
    Med Phys; 2006 Apr; 33(4):828-39. PubMed ID: 16696458
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of a Monte Carlo model for multi leaf collimator based electron delivery.
    Kaluarachchi MM; Saleh ZH; Schwer ML; Klein EE
    Med Phys; 2020 Aug; 47(8):3586-3599. PubMed ID: 32324289
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculation.
    Tyagi N; Moran JM; Litzenberg DW; Bielajew AF; Fraass BA; Chetty IJ
    Med Phys; 2007 Feb; 34(2):651-63. PubMed ID: 17388183
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance of a multi leaf collimator system for MR-guided radiation therapy.
    Cai B; Li H; Yang D; Rodriguez V; Curcuru A; Wang Y; Wen J; Kashani R; Mutic S; Green O
    Med Phys; 2017 Dec; 44(12):6504-6514. PubMed ID: 28887825
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of dosimetric effect of leaf position in a radiation field of an 80 leaf multileaf collimator fitted to the LINAC head as tertiary collimator.
    Kehwar TS; Bhardwaj AK; Chakarvarti SK
    J Appl Clin Med Phys; 2006 Aug; 7(3):43-54. PubMed ID: 17533348
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo simulation of a dynamic MLC based on a multiple source model.
    Fix MK; Manser P; Born EJ; Mini R; Rüegsegger P
    Phys Med Biol; 2001 Dec; 46(12):3241-57. PubMed ID: 11768503
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo and experimental investigations of multileaf collimated electron beams for modulated electron radiation therapy.
    Lee MC; Jiang SB; Ma CM
    Med Phys; 2000 Dec; 27(12):2708-18. PubMed ID: 11190954
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A feasibility study of Dynamic Phantom scanner for quality assurance of photon beam profiles at various gantry angles.
    Zhang Y; Hsi WC; Chu JC; Bernard DB; Abrams RA
    J Appl Clin Med Phys; 2005; 6(2):50-61. PubMed ID: 15940212
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intensity modulated radiation therapy with multileaf collimators of different leaf widths: a comparison of achievable dose distributions.
    Nill S; Tücking T; Münter MW; Oelfke U
    Radiother Oncol; 2005 Apr; 75(1):106-11. PubMed ID: 15878108
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development and validation of a BEAMnrc component module for accurate Monte Carlo modelling of the Varian dynamic Millennium multileaf collimator.
    Heath E; Seuntjens J
    Phys Med Biol; 2003 Dec; 48(24):4045-63. PubMed ID: 14727750
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Investigation of secondary neutron dose for 18 MV dynamic MLC IMRT delivery.
    Howell RM; Ferenci MS; Hertel NE; Fullerton GD
    Med Phys; 2005 Mar; 32(3):786-93. PubMed ID: 15839351