These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 11805952)

  • 21. Factors affecting left ventricular mass regression after aortic valve replacement with stentless valves.
    Del Rizzo DF; Abdoh A; Cartier P; Doty D; Westaby S
    Semin Thorac Cardiovasc Surg; 1999 Oct; 11(4 Suppl 1):114-20. PubMed ID: 10660178
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Aortic valve replacement with stentless porcine aortic valves: a ten-year experience.
    David TE; Feindel CM; Scully HE; Bos J; Rakowski H
    J Heart Valve Dis; 1998 May; 7(3):250-4. PubMed ID: 9651835
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Short-term hemodynamic performance of the Sorin Freedom SOLO stentless valve.
    Da Col U; Di Bella I; Bardelli G; Ramoni E; Affronti A; Vidili A; Ragni T
    J Heart Valve Dis; 2007 Sep; 16(5):546-50. PubMed ID: 17944127
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Early postoperative hemodynamic performances of stented versus stentless aortic xenografts in aortic valve replacement in elderly patients: a comparative study.
    Burgazli KM; Mericliler M; Erenturk S; Polat ZP; Atmaca N
    Eur Rev Med Pharmacol Sci; 2013 Jul; 17(14):1894-900. PubMed ID: 23877854
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A three year experience with the toronto stentless porcine valve.
    Berg GA; McLaughlin KE; Akar R; Pathi V; MacArthur KJ
    Ann Thorac Cardiovasc Surg; 1998 Jun; 4(3):138-45. PubMed ID: 9660911
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Long-term results with the Biocor-SJM stentless porcine aortic bioprosthesis.
    Vrandecic M; Fantini FA; Filho BG; de O; da C; Vrandecic E
    J Heart Valve Dis; 2002 Jan; 11(1):47-53. PubMed ID: 11843505
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Early hemodynamic performance of the BioValsalva valved conduit after aortic root replacement.
    Badiu CC; Deutsch MA; Bleiziffer S; Krane M; Hettich I; Voss B; Mazzitelli D; Lange R
    J Heart Valve Dis; 2014 Jan; 23(1):97-104. PubMed ID: 24779335
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Three-dimensional flow velocity quantification of Freestyle aortic stentless bioprosthesis by magnetic resonance imaging: surgical consideration.
    Matsue H; Sawa Y; Takahashi T; Matsumiya G; Ohtake S; Hamada S; Ueguchi T; Matsuda H
    Semin Thorac Cardiovasc Surg; 2001 Oct; 13(4 Suppl 1):60-6. PubMed ID: 11805951
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The subcoronary Toronto stentless versus supra-annular Perimount stented replacement aortic valve: early clinical and hemodynamic results of a randomized comparison in 160 patients.
    Chambers JB; Rimington HM; Hodson F; Rajani R; Blauth CI
    J Thorac Cardiovasc Surg; 2006 Apr; 131(4):878-2. PubMed ID: 16580447
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Three years' experience with the sorin pericarbon stentless prosthesis: mid-term results with three different implantation techniques.
    Nagy ZL; Bodi A; Len A; Balogh I; Peterffy A
    J Heart Valve Dis; 2005 Jan; 14(1):72-7. PubMed ID: 15700439
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement.
    Bakhtiary F; Schiemann M; Dzemali O; Dogan S; Schächinger V; Ackermann H; Moritz A; Kleine P
    J Am Coll Cardiol; 2007 Feb; 49(7):790-6. PubMed ID: 17306709
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Early hemodynamic results of the Shelhigh SuperStentless aortic bioprostheses.
    Cattaneo P; Bruno VD; Mariscalco G; Marchetti P; Ferrarese S; Salerno-Uriarte J; Sala A
    J Card Surg; 2007; 22(5):379-84. PubMed ID: 17803572
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Randomized controlled trial of stented and stentless aortic bioprotheses: hemodynamic performance at 3 years.
    Williams RJ; Muir DF; Pathi V; MacArthur K; Berg GA
    Semin Thorac Cardiovasc Surg; 1999 Oct; 11(4 Suppl 1):93-7. PubMed ID: 10660174
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Hemodynamic features of the freestyle aortic bioprosthesis compared with stented bioprosthesis.
    Dumesnil JG; LeBlanc MH; Cartier PC; Métras J; Desaulniers D; Doyle DP; Lemieux MD; Raymond G
    Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S130-3. PubMed ID: 9930433
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Stentless aortic valves are hemodynamically superior to stented valves during mid-term follow-up: a large retrospective study.
    Borger MA; Carson SM; Ivanov J; Rao V; Scully HE; Feindel CM; David TE
    Ann Thorac Surg; 2005 Dec; 80(6):2180-5. PubMed ID: 16305867
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of stentless kangaroo aortic valves in the mitral position of juvenile sheep.
    Hodge AJ; Neethling WM; Glancy R
    J Heart Valve Dis; 2004 Jul; 13(4):681-8. PubMed ID: 15311878
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Are stentless valves hemodynamically superior to stented valves? Long-term follow-up of a randomized trial comparing Carpentier-Edwards pericardial valve with the Toronto Stentless Porcine Valve.
    Cohen G; Zagorski B; Christakis GT; Joyner CD; Vincent J; Sever J; Harbi S; Feder-Elituv R; Moussa F; Goldman BS; Fremes SE
    J Thorac Cardiovasc Surg; 2010 Apr; 139(4):848-59. PubMed ID: 20080264
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Hemodynamic performance evaluation of small aortic ATS Medical valves by Doppler echocardiography.
    Kirzner CF; Vinals B; Moya J; Puente JG; Rabago R; Artiz V; Martinelli J; Fraile-Chief J
    J Heart Valve Dis; 1997 Nov; 6(6):661-5. PubMed ID: 9427139
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Hemodynamic performance of stentless porcine bioprosthesis and mechanical bileaflet prosthesis using dobutamine stress echocardiography.
    Morsy S; Zahran M; Usama M; Elkhashab K; Abdel-Aziz I
    Semin Thorac Cardiovasc Surg; 2001 Oct; 13(4 Suppl 1):129-35. PubMed ID: 11805961
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Eight-year hemodynamic follow-up after aortic valve replacement with the Toronto SPV stentless aortic valve.
    Bach DS; Goldman B; Verrier E; Petracek M; Wood J; Goldman S; David T;
    Semin Thorac Cardiovasc Surg; 2001 Oct; 13(4 Suppl 1):173-9. PubMed ID: 11805968
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.