These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 11811415)

  • 1. Effects of fragile ions on mass resolution and on isolation for tandem mass spectrometry in the quadrupole ion trap mass spectrometer.
    McClellan JE; Murphy JP; Mulholland JJ; Yost RA
    Anal Chem; 2002 Jan; 74(2):402-12. PubMed ID: 11811415
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization of protonated phospholipids as fragile ions in quadrupole ion trap mass spectrometry.
    Garrett TJ; Merves M; Yost RA
    Int J Mass Spectrom; 2011 Dec; 308(2-3):299-306. PubMed ID: 22247650
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Origin of mass shifts in the quadrupole ion trap: dissociation of fragile ions observed with a hybrid ion trap/mass filter instrument.
    Murphy JP; Yost RA
    Rapid Commun Mass Spectrom; 2000; 14(4):270-3. PubMed ID: 10669886
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimized precursor ion selection for labile ions in a linear ion trap mass spectrometer and its impact on quantification using selected reaction monitoring.
    Lee HS; Shin KO; Jo SC; Lee YM; Yim YH
    J Mass Spectrom; 2014 Dec; 49(12):1234-8. PubMed ID: 25476940
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Space-charge effects with mass-selective axial ejection from a linear quadrupole ion trap.
    Qiao H; Gao C; Mao D; Konenkov N; Douglas DJ
    Rapid Commun Mass Spectrom; 2011 Dec; 25(23):3509-20. PubMed ID: 22095499
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mixture analysis using a quadrupole mass filter/quadrupole ion trap mass spectrometer.
    Jonscher KR; Yates JR
    Anal Chem; 1996 Feb; 68(4):659-67. PubMed ID: 8999740
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Resonance activation and collision-induced-dissociation of ions using rectangular wave dipolar potentials in a digital ion trap mass spectrometer.
    Xu F; Wang L; Dai X; Fang X; Ding CF
    J Am Soc Mass Spectrom; 2014 Apr; 25(4):556-62. PubMed ID: 24449517
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Adaptation and Operation of a Quadrupole/Time-of-Flight Tandem Mass Spectrometer for High Mass Ion/Ion Reaction Studies.
    Bhanot JS; Fabijanczuk KC; Abdillahi AM; Chao HC; Pizzala NJ; Londry FA; Dziekonski ET; Hager JW; McLuckey SA
    Int J Mass Spectrom; 2022 Aug; 478():. PubMed ID: 37032994
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Investigations into the use of a reverse scan in a quadrupole ion trap mass spectrometer.
    Dobson G; Murrell J; Despeyroux D; Wind F; Tabet JC
    Rapid Commun Mass Spectrom; 2003; 17(14):1657-64. PubMed ID: 12845593
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mass selection of ions from beams using waveform isolation in radiofrequency quadrupoles.
    Song Q; Smith SA; Gao L; Xu W; Volný M; Ouyang Z; Cooks RG
    Anal Chem; 2009 Mar; 81(5):1833-40. PubMed ID: 19178148
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Tandem infrared multiphoton dissociation and collisionally activated dissociation techniques in a quadrupole ion trap.
    Goolsby BJ; Brodbelt JS
    Anal Chem; 2001 Mar; 73(6):1270-6. PubMed ID: 11305662
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Isolation of Crude Oil Peaks Differing by
    Cho E; Riches E; Palmer M; Giles K; Ujma J; Kim S
    Anal Chem; 2019 Nov; 91(22):14268-14274. PubMed ID: 31613096
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A quadrupole ion trap/time-of-flight mass spectrometer with a parabolic reflectron.
    Doroshenko VM; Cotter RJ
    J Mass Spectrom; 1998 Apr; 33(4):305-18. PubMed ID: 9597767
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Chemical mass shifts in resonance ejection experiments in the quadrupole ion trap.
    Li H; Plass WR; Patterson GE; Cooks RG
    J Mass Spectrom; 2002 Oct; 37(10):1051-8. PubMed ID: 12375279
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hybrid triple quadrupole-linear ion trap mass spectrometry in fragmentation mechanism studies: application to structure elucidation of buspirone and one of its metabolites.
    Zhang MY; Pace N; Kerns EH; Kleintop T; Kagan N; Sakuma T
    J Mass Spectrom; 2005 Aug; 40(8):1017-29. PubMed ID: 15934027
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Broad-Spectrum Drug Screening Using Liquid Chromatography-Hybrid Triple-Quadrupole Linear Ion Trap Mass Spectrometry.
    Stone J
    Methods Mol Biol; 2016; 1383():133-51. PubMed ID: 26660183
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental Characterization of Secular Frequency Scanning in Ion Trap Mass Spectrometers.
    Snyder DT; Pulliam CJ; Wiley JS; Duncan J; Cooks RG
    J Am Soc Mass Spectrom; 2016 Jul; 27(7):1243-55. PubMed ID: 27032650
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Investigation of collisional-activation decomposition process and spectra in the transport region of an electrospray single-quadrupole mass spectrometer.
    Voyksner RD; Pack T
    Rapid Commun Mass Spectrom; 1991 Jun; 5(6):263-8. PubMed ID: 1804417
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analysis of protonated and alkali metal cationized aminoglycoside antibiotics by collision-activated dissociation and infrared multi-photon dissociation in the quadrupole ion trap.
    Goolsby BJ; Brodbelt JS
    J Mass Spectrom; 2000 Aug; 35(8):1011-24. PubMed ID: 10973001
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tandem mass spectrometry in quadrupole ion trap and ion cyclotron resonance mass spectrometers.
    Payne AH; Glish GL
    Methods Enzymol; 2005; 402():109-48. PubMed ID: 16401508
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.