These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
409 related articles for article (PubMed ID: 11811826)
21. Colonic polyps: complementary role of computer-aided detection in CT colonography. Summers RM; Jerebko AK; Franaszek M; Malley JD; Johnson CD Radiology; 2002 Nov; 225(2):391-9. PubMed ID: 12409571 [TBL] [Abstract][Full Text] [Related]
22. Automatic colon polyp flagging via geometric and texture features. Fiori M; Musé P; Aguirre S; Sapiro G Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():3170-3. PubMed ID: 21096596 [TBL] [Abstract][Full Text] [Related]
23. CT colonography with computer-aided detection: automated recognition of ileocecal valve to reduce number of false-positive detections. Summers RM; Yao J; Johnson CD Radiology; 2004 Oct; 233(1):266-72. PubMed ID: 15454623 [TBL] [Abstract][Full Text] [Related]
24. Edge displacement field-based classification for improved detection of polyps in CT colonography. Acar B; Beaulieu CF; Göktürk SB; Tomasi C; Paik DS; Jeffrey RB; Yee J; Napel S IEEE Trans Med Imaging; 2002 Dec; 21(12):1461-7. PubMed ID: 12588030 [TBL] [Abstract][Full Text] [Related]
25. Increasing computer-aided detection specificity by projection features for CT colonography. Zhu H; Liang Z; Pickhardt PJ; Barish MA; You J; Fan Y; Lu H; Posniak EJ; Richards RJ; Cohen HL Med Phys; 2010 Apr; 37(4):1468-81. PubMed ID: 20443468 [TBL] [Abstract][Full Text] [Related]
26. Massive-training artificial neural network (MTANN) for reduction of false positives in computer-aided detection of polyps: Suppression of rectal tubes. Suzuki K; Yoshida H; Näppi J; Dachman AH Med Phys; 2006 Oct; 33(10):3814-24. PubMed ID: 17089846 [TBL] [Abstract][Full Text] [Related]
27. Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: pilot study. Li P; Napel S; Acar B; Paik DS; Jeffrey RB; Beaulieu CF Med Phys; 2004 Oct; 31(10):2912-23. PubMed ID: 15543800 [TBL] [Abstract][Full Text] [Related]
28. Polyp detection with CT colonography: primary 3D endoluminal analysis versus primary 2D transverse analysis with computer-assisted reader software. Taylor SA; Halligan S; Slater A; Goh V; Burling DN; Roddie ME; Honeyfield L; McQuillan J; Amin H; Dehmeshki J Radiology; 2006 Jun; 239(3):759-67. PubMed ID: 16543593 [TBL] [Abstract][Full Text] [Related]
29. Improving initial polyp candidate extraction for CT colonography. Zhu H; Fan Y; Lu H; Liang Z Phys Med Biol; 2010 Apr; 55(7):2087-102. PubMed ID: 20299733 [TBL] [Abstract][Full Text] [Related]
30. Computer-assisted detection of colonic polyps with CT colonography using neural networks and binary classification trees. Jerebko AK; Summers RM; Malley JD; Franaszek M; Johnson CD Med Phys; 2003 Jan; 30(1):52-60. PubMed ID: 12557979 [TBL] [Abstract][Full Text] [Related]
31. [CT-colonography with the 16-slice CT for the diagnostic evaluation of colorectal neoplasms and inflammatory colon diseases]. Röttgen R; Schröder RJ; Lorenz M; Herbel A; Fischbach F; Herzog H; Lopez-Häninnen E; Gutberlet M; Hoffmann K; Helmig K; Felix R Rofo; 2003 Oct; 175(10):1384-91. PubMed ID: 14556108 [TBL] [Abstract][Full Text] [Related]
32. Efficient computerized polyp detection for CT colonography. Li H; Pineau B; Santago P J Digit Imaging; 2005 Mar; 18(1):55-65. PubMed ID: 15645333 [No Abstract] [Full Text] [Related]
33. Automated detection of polyps with CT colonography: evaluation of volumetric features for reduction of false-positive findings. Näppi J; Yoshida H Acad Radiol; 2002 Apr; 9(4):386-97. PubMed ID: 11942653 [TBL] [Abstract][Full Text] [Related]
34. Linear measurement of polyps in CT colonography using level sets on 3D surfaces. Tan S; Yao J; Ward MM; Summers RM Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():3617-20. PubMed ID: 19964614 [TBL] [Abstract][Full Text] [Related]
35. Hybrid segmentation of colon filled with air and opacified fluid for CT colonography. Franaszek M; Summers RM; Pickhardt PJ; Choi JR IEEE Trans Med Imaging; 2006 Mar; 25(3):358-68. PubMed ID: 16524091 [TBL] [Abstract][Full Text] [Related]
36. CT colonography: automated measurement of colonic polyps compared with manual techniques--human in vitro study. Taylor SA; Slater A; Halligan S; Honeyfield L; Roddie ME; Demeshski J; Amin H; Burling D Radiology; 2007 Jan; 242(1):120-8. PubMed ID: 17105850 [TBL] [Abstract][Full Text] [Related]
37. Performance of a previously validated CT colonography computer-aided detection system in a new patient population. Summers RM; Handwerker LR; Pickhardt PJ; Van Uitert RL; Deshpande KK; Yeshwant S; Yao J; Franaszek M AJR Am J Roentgenol; 2008 Jul; 191(1):168-74. PubMed ID: 18562741 [TBL] [Abstract][Full Text] [Related]
38. Reduction of false positives by internal features for polyp detection in CT-based virtual colonoscopy. Wang Z; Liang Z; Li L; Li X; Li B; Anderson J; Harrington D Med Phys; 2005 Dec; 32(12):3602-16. PubMed ID: 16475759 [TBL] [Abstract][Full Text] [Related]
39. Polyp detection at CT colonography: inadequate primary 3D endoluminal reference standard precludes meaningful comparison. Pickhardt PJ Radiology; 2007 Jul; 244(1):316-7. PubMed ID: 17581913 [No Abstract] [Full Text] [Related]
40. Surface normal overlap: a computer-aided detection algorithm with application to colonic polyps and lung nodules in helical CT. Paik DS; Beaulieu CF; Rubin GD; Acar B; Jeffrey RB; Yee J; Dey J; Napel S IEEE Trans Med Imaging; 2004 Jun; 23(6):661-75. PubMed ID: 15191141 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]