105 related articles for article (PubMed ID: 11817874)
1. Excessive heat generation during cutting of cement in the Robodoc hip-revision procedure.
Nogler M; Krismer M; Haid C; Ogon M; Bach C; Wimmer C
Acta Orthop Scand; 2001 Dec; 72(6):595-9. PubMed ID: 11817874
[TBL] [Abstract][Full Text] [Related]
2. Heat generation during cement removal in revision total hip replacement - a comparison of three methods.
Nogler M; Mayr E
Hip Int; 2010; 20(3):308-13. PubMed ID: 20640991
[TBL] [Abstract][Full Text] [Related]
3. Histological findings of the femoral bone after cement removal in hip revision. An experimental study of cadaver femurs with two different cement removal procedures.
Porsch M; Schmidt J
Arch Orthop Trauma Surg; 2003 Jun; 123(5):199-202. PubMed ID: 12743715
[TBL] [Abstract][Full Text] [Related]
4. In vitro cyclic testing of the Exeter stem after cement within cement revision.
Wilson LJ; Bell CG; Weinrauch P; Crawford R
J Arthroplasty; 2009 Aug; 24(5):789-94. PubMed ID: 18534400
[TBL] [Abstract][Full Text] [Related]
5. [Effect of femoral intramedullary irrigation on periprosthetic cement distribution: jet lavage versus syringe lavage].
Wirtz D; Sellei RM; Portheine F; Prescher A; Weber M
Z Orthop Ihre Grenzgeb; 2001; 139(5):410-4. PubMed ID: 11605292
[TBL] [Abstract][Full Text] [Related]
6. Comparison of Ho:YAG laser and coblation for interface tissue removal in minimally invasive hip refixation procedures.
Kraaij G; Malan DF; van der Heide HJ; Dankelman J; Nelissen RG; Valstar ER
Med Eng Phys; 2012 Apr; 34(3):370-7. PubMed ID: 21855390
[TBL] [Abstract][Full Text] [Related]
7. [Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis].
Massin P; Astoin E; Lavaste F
Rev Chir Orthop Reparatrice Appar Mot; 2003 Apr; 89(2):134-43. PubMed ID: 12844057
[TBL] [Abstract][Full Text] [Related]
8. Cement mantle retention: filling the hole.
Cross M; Bostrom M
Orthopedics; 2009 Sep; 32(9):. PubMed ID: 19751012
[TBL] [Abstract][Full Text] [Related]
9. [A simple technique of removal of femoral cement plug in total hip prosthesis revision].
Julliard R
Rev Chir Orthop Reparatrice Appar Mot; 1996; 82(2):161-5. PubMed ID: 8761102
[TBL] [Abstract][Full Text] [Related]
10. [An evaluation of the methods used for removal of components and cement in revision hip arthroplasty].
Erdemli B
Acta Orthop Traumatol Turc; 2004; 38(3):188-94. PubMed ID: 15347918
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of the effects of implant materials and designs on thermal necrosis of bone in cemented hip arthroplasty.
Li C; Kotha S; Mason J
Biomed Mater Eng; 2003; 13(4):419-28. PubMed ID: 14646056
[TBL] [Abstract][Full Text] [Related]
12. Thermal effects of cement mantle thickness for hip resurfacing.
Little JP; Gray HA; Murray DW; Beard DJ; Gill HS
J Arthroplasty; 2008 Apr; 23(3):454-8. PubMed ID: 18358388
[TBL] [Abstract][Full Text] [Related]
13. Finite element temperature analysis of a total hip replacement and measurement of PMMA curing temperatures.
Swenson LW; Schurman DJ; Piziali Rl
J Biomed Mater Res; 1981 Jan; 15(1):83-96. PubMed ID: 7348707
[TBL] [Abstract][Full Text] [Related]
14. In vivo failure analysis of intramedullary cement restrictors in 100 hip arthroplasties.
Bitsch RG; Breusch SJ; Thomsen M; Schneider S; Heisel C
Acta Orthop; 2007 Aug; 78(4):485-90. PubMed ID: 17966002
[TBL] [Abstract][Full Text] [Related]
15. A device for removal of femoral distal cement plug during hip revision arthroplasty: a high-powered drill equipped with a centralizer.
Jingushi S; Noguchi Y; Shuto T; Nakashima T; Iwamoto Y
J Arthroplasty; 2000 Feb; 15(2):231-3. PubMed ID: 10708092
[TBL] [Abstract][Full Text] [Related]
16. Computer-assisted fluoroscopic navigation system for removal of distal femoral bone cement in revision total hip arthroplasty.
Akiyama H; Kawanabe K; Goto K; Ohnishi E; Nakamura T
J Arthroplasty; 2007 Apr; 22(3):445-8. PubMed ID: 17400101
[TBL] [Abstract][Full Text] [Related]
17. [Early aseptic loosening of the CF 30 femoral stem].
Kovanda M; Havlícek V; Hudec J
Acta Chir Orthop Traumatol Cech; 2007 Feb; 74(1):59-64. PubMed ID: 17331456
[TBL] [Abstract][Full Text] [Related]
18. [Comparison of temperature increments in bone cavities induced by methylmethacrylate and heated saline solution].
Aksu N; Hiz VM; Bilgili MG; Aksu T; Düzgün O
Acta Orthop Traumatol Turc; 2003; 37(5):386-94. PubMed ID: 14963395
[TBL] [Abstract][Full Text] [Related]
19. Precooling of the femoral canal enhances shear strength at the cement-prosthesis interface and reduces the polymerization temperature.
Hsieh PH; Tai CL; Chang YH; Lee MS; Shih HN; Shih CH
J Orthop Res; 2006 Sep; 24(9):1809-14. PubMed ID: 16865715
[TBL] [Abstract][Full Text] [Related]
20. Porosity of neat and composite bone cement mantles.
Hansen CL; McQueen DA; Friis EA; Cooke FW; Widenhouse CW
J Arthroplasty; 2008 Feb; 23(2):279-86. PubMed ID: 18280425
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]