BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 11829439)

  • 1. Effects of the sterilisation method on the wear of UHMWPE acetabular cups tested in a hip joint simulator.
    Affatato S; Bordini B; Fagnano C; Taddei P; Tinti A; Toni A
    Biomaterials; 2002 Mar; 23(6):1439-46. PubMed ID: 11829439
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The performance of gamma- and EtO-sterilised UHMWPE acetabular cups tested under severe simulator conditions. Part 2: wear particle characteristics with isolation protocols.
    Affatato S; Bersaglia G; Emiliani D; Foltran I; Taddei P; Reggiani M; Ferrieri P; Toni A
    Biomaterials; 2003 Oct; 24(22):4045-55. PubMed ID: 12834600
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The performance of gamma- and EtO-sterilised UHWMPE acetabular cups tested under severe simulator conditions. Part 1: role of the third-body wear process.
    Affatato S; Bersaglia G; Foltran I; Taddei P; Fini G; Toni A
    Biomaterials; 2002 Dec; 23(24):4839-46. PubMed ID: 12361624
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator.
    McKellop HA; Shen FW; Campbell P; Ota T
    J Orthop Res; 1999 May; 17(3):329-39. PubMed ID: 10376720
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study.
    McKellop H; Shen FW; Lu B; Campbell P; Salovey R
    J Bone Joint Surg Am; 2000 Dec; 82(12):1708-25. PubMed ID: 11130644
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Effect of sterilisation with formaldehyde, gamma irradiation and ethylene oxide on the properties of polyethylene joint replacement components].
    Fulín P; Pokorný D; Slouf M; Vacková T; Dybal J; Sosna A
    Acta Chir Orthop Traumatol Cech; 2014; 81(1):33-9. PubMed ID: 24755055
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions.
    Affatato S; Bersaglia G; Rocchi M; Taddei P; Fagnano C; Toni A
    Biomaterials; 2005 Jun; 26(16):3259-67. PubMed ID: 15603821
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE.
    Besong AA; Hailey JL; Ingham E; Stone M; Wroblewski BM; Fisher J
    Biomed Mater Eng; 1997; 7(1):59-65. PubMed ID: 9171903
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of head surface roughness and sterilization on wear of UHMWPE acetabular cups.
    Jedenmalm A; Affatato S; Taddei P; Leardini W; Gedde UW; Fagnano C; Viceconti M
    J Biomed Mater Res A; 2009 Sep; 90(4):1032-42. PubMed ID: 18671264
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does the addition of vitamin E to conventional UHMWPE improve the wear performance of hip acetabular cups? Micro-Raman characterization of differently processed polyethylene acetabular cups worn on a hip joint simulator.
    Di Foggia M; Affatato S; Taddei P
    Braz J Med Biol Res; 2020; 53(10):e9930. PubMed ID: 32813853
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vivo change of elastic property in polyethylene acetabular components.
    Kusaba A; Kondo S; Mori Y; Kuroki Y
    Mod Rheumatol; 2008; 18(2):140-5. PubMed ID: 18292965
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Non-destructively differentiating the roles of creep, wear and oxidation in long-term in vivo exposed polyethylene cups.
    Pezzotti G; Takahashi Y; Takamatsu S; Puppulin L; Nishii T; Miki H; Sugano N
    J Biomater Sci Polym Ed; 2011; 22(16):2165-84. PubMed ID: 21067657
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A tribological study of UHMWPE acetabular cups and polyurethane compliant layer acetabular cups.
    Smith SL; Ash HE; Unsworth A
    J Biomed Mater Res; 2000; 53(6):710-6. PubMed ID: 11074431
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.
    Endo MM; Barbour PS; Barton DC; Fisher J; Tipper JL; Ingham E; Stone MH
    Biomed Mater Eng; 2001; 11(1):23-35. PubMed ID: 11281576
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads.
    Galvin A; Brockett C; Williams S; Hatto P; Burton A; Isaac G; Stone M; Ingham E; Fisher J
    Proc Inst Mech Eng H; 2008 Oct; 222(7):1073-80. PubMed ID: 19024155
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator.
    Smith SL; Unsworth A
    Proc Inst Mech Eng H; 1999; 213(6):475-83. PubMed ID: 10635696
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator.
    Saikko V; Calonius O; Keränen J
    J Biomed Mater Res; 2002; 63(6):848-53. PubMed ID: 12418033
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation.
    Besong AA; Tipper JL; Ingham E; Stone MH; Wroblewski BM; Fisher J
    J Bone Joint Surg Br; 1998 Mar; 80(2):340-4. PubMed ID: 9546473
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vivo UHMWPE biodegradation of retrieved prosthesis.
    Costa L; Luda MP; Trossarelli L; Brach del Prever EM; Crova M; Gallinaro P
    Biomaterials; 1998 Aug; 19(15):1371-85. PubMed ID: 9758037
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fluid absorption study in ultra-high molecular weight polyethylene (UHMWPE) sterilized and unsterilized acetabular cups.
    Affatato S; Vandelli C; Bordini B; Toni A
    Proc Inst Mech Eng H; 2001; 215(1):107-11. PubMed ID: 11323978
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.