These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
198 related articles for article (PubMed ID: 11829439)
1. Effects of the sterilisation method on the wear of UHMWPE acetabular cups tested in a hip joint simulator. Affatato S; Bordini B; Fagnano C; Taddei P; Tinti A; Toni A Biomaterials; 2002 Mar; 23(6):1439-46. PubMed ID: 11829439 [TBL] [Abstract][Full Text] [Related]
2. The performance of gamma- and EtO-sterilised UHMWPE acetabular cups tested under severe simulator conditions. Part 2: wear particle characteristics with isolation protocols. Affatato S; Bersaglia G; Emiliani D; Foltran I; Taddei P; Reggiani M; Ferrieri P; Toni A Biomaterials; 2003 Oct; 24(22):4045-55. PubMed ID: 12834600 [TBL] [Abstract][Full Text] [Related]
3. The performance of gamma- and EtO-sterilised UHWMPE acetabular cups tested under severe simulator conditions. Part 1: role of the third-body wear process. Affatato S; Bersaglia G; Foltran I; Taddei P; Fini G; Toni A Biomaterials; 2002 Dec; 23(24):4839-46. PubMed ID: 12361624 [TBL] [Abstract][Full Text] [Related]
4. Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator. McKellop HA; Shen FW; Campbell P; Ota T J Orthop Res; 1999 May; 17(3):329-39. PubMed ID: 10376720 [TBL] [Abstract][Full Text] [Related]
5. Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. McKellop H; Shen FW; Lu B; Campbell P; Salovey R J Bone Joint Surg Am; 2000 Dec; 82(12):1708-25. PubMed ID: 11130644 [TBL] [Abstract][Full Text] [Related]
6. [Effect of sterilisation with formaldehyde, gamma irradiation and ethylene oxide on the properties of polyethylene joint replacement components]. Fulín P; Pokorný D; Slouf M; Vacková T; Dybal J; Sosna A Acta Chir Orthop Traumatol Cech; 2014; 81(1):33-9. PubMed ID: 24755055 [TBL] [Abstract][Full Text] [Related]
7. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions. Affatato S; Bersaglia G; Rocchi M; Taddei P; Fagnano C; Toni A Biomaterials; 2005 Jun; 26(16):3259-67. PubMed ID: 15603821 [TBL] [Abstract][Full Text] [Related]
8. A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE. Besong AA; Hailey JL; Ingham E; Stone M; Wroblewski BM; Fisher J Biomed Mater Eng; 1997; 7(1):59-65. PubMed ID: 9171903 [TBL] [Abstract][Full Text] [Related]
9. Effect of head surface roughness and sterilization on wear of UHMWPE acetabular cups. Jedenmalm A; Affatato S; Taddei P; Leardini W; Gedde UW; Fagnano C; Viceconti M J Biomed Mater Res A; 2009 Sep; 90(4):1032-42. PubMed ID: 18671264 [TBL] [Abstract][Full Text] [Related]
10. Does the addition of vitamin E to conventional UHMWPE improve the wear performance of hip acetabular cups? Micro-Raman characterization of differently processed polyethylene acetabular cups worn on a hip joint simulator. Di Foggia M; Affatato S; Taddei P Braz J Med Biol Res; 2020; 53(10):e9930. PubMed ID: 32813853 [TBL] [Abstract][Full Text] [Related]
11. In vivo change of elastic property in polyethylene acetabular components. Kusaba A; Kondo S; Mori Y; Kuroki Y Mod Rheumatol; 2008; 18(2):140-5. PubMed ID: 18292965 [TBL] [Abstract][Full Text] [Related]
12. Non-destructively differentiating the roles of creep, wear and oxidation in long-term in vivo exposed polyethylene cups. Pezzotti G; Takahashi Y; Takamatsu S; Puppulin L; Nishii T; Miki H; Sugano N J Biomater Sci Polym Ed; 2011; 22(16):2165-84. PubMed ID: 21067657 [TBL] [Abstract][Full Text] [Related]
13. A tribological study of UHMWPE acetabular cups and polyurethane compliant layer acetabular cups. Smith SL; Ash HE; Unsworth A J Biomed Mater Res; 2000; 53(6):710-6. PubMed ID: 11074431 [TBL] [Abstract][Full Text] [Related]
14. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene. Endo MM; Barbour PS; Barton DC; Fisher J; Tipper JL; Ingham E; Stone MH Biomed Mater Eng; 2001; 11(1):23-35. PubMed ID: 11281576 [TBL] [Abstract][Full Text] [Related]
15. Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads. Galvin A; Brockett C; Williams S; Hatto P; Burton A; Isaac G; Stone M; Ingham E; Fisher J Proc Inst Mech Eng H; 2008 Oct; 222(7):1073-80. PubMed ID: 19024155 [TBL] [Abstract][Full Text] [Related]
16. A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator. Smith SL; Unsworth A Proc Inst Mech Eng H; 1999; 213(6):475-83. PubMed ID: 10635696 [TBL] [Abstract][Full Text] [Related]
17. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator. Saikko V; Calonius O; Keränen J J Biomed Mater Res; 2002; 63(6):848-53. PubMed ID: 12418033 [TBL] [Abstract][Full Text] [Related]
18. Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation. Besong AA; Tipper JL; Ingham E; Stone MH; Wroblewski BM; Fisher J J Bone Joint Surg Br; 1998 Mar; 80(2):340-4. PubMed ID: 9546473 [TBL] [Abstract][Full Text] [Related]
19. In vivo UHMWPE biodegradation of retrieved prosthesis. Costa L; Luda MP; Trossarelli L; Brach del Prever EM; Crova M; Gallinaro P Biomaterials; 1998 Aug; 19(15):1371-85. PubMed ID: 9758037 [TBL] [Abstract][Full Text] [Related]
20. Fluid absorption study in ultra-high molecular weight polyethylene (UHMWPE) sterilized and unsterilized acetabular cups. Affatato S; Vandelli C; Bordini B; Toni A Proc Inst Mech Eng H; 2001; 215(1):107-11. PubMed ID: 11323978 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]