152 related articles for article (PubMed ID: 11836999)
21. Stentless bioprosthetic aortic valve replacement after a homograft root replacement: Toronto SPV implantation after a homograft root.
Bakaeen FG; Walkes JC; Reardon MJ
Ann Thorac Surg; 2005 Apr; 79(4):1397-9. PubMed ID: 15797091
[TBL] [Abstract][Full Text] [Related]
22. Mid-term results of freestyle aortic stentless bioprosthetic valve: clinical impact of quantitative analysis of in-vivo three-dimensional flow velocity profile by magnetic resonance imaging.
Matsue H; Sawa Y; Matsumiya G; Matsuda H; Hamada S
J Heart Valve Dis; 2005 Sep; 14(5):630-6. PubMed ID: 16245502
[TBL] [Abstract][Full Text] [Related]
23. St Jude Epic heart valve bioprostheses versus native human and porcine aortic valves - comparison of mechanical properties.
Kalejs M; Stradins P; Lacis R; Ozolanta I; Pavars J; Kasyanov V
Interact Cardiovasc Thorac Surg; 2009 May; 8(5):553-6. PubMed ID: 19190025
[TBL] [Abstract][Full Text] [Related]
24. Design and performance characteristics of the Pericarbon Stentless valve.
Stacchino C; Bona G; Rinaldi S; Vallana F
J Heart Valve Dis; 1995 Jul; 4 Suppl 1():S102-5. PubMed ID: 8581203
[TBL] [Abstract][Full Text] [Related]
25. [Hemodynamic performance of newly developed composite stentless porcine aortic valve: in vitro testing and in vivo experiment with sheep].
Song GM; Zhou JY; Hu SS; Cui JW; Song YH; Tang Y; Zhang Y; Jiang H; Yuan WM; Song XY
Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(29):2059-63. PubMed ID: 19080436
[TBL] [Abstract][Full Text] [Related]
26. Stentless full root bioprosthesis in surgery for complex aortic valve-ascending aortic disease: a single center experience of over 300 patients.
Dapunt OE; Easo J; Hölzl PP; Murin P; Südkamp M; Horst M; Natour E
Eur J Cardiothorac Surg; 2008 Apr; 33(4):554-9. PubMed ID: 18282760
[TBL] [Abstract][Full Text] [Related]
27. Preassembled stentless valved-conduit for the replacement of the ascending aorta and aortic root.
Bochenek-Klimczyk K; Lau KK; Galiñanes M; Sosnowski AW
Interact Cardiovasc Thorac Surg; 2008 Dec; 7(6):964-8. PubMed ID: 18713779
[TBL] [Abstract][Full Text] [Related]
28. Aortic root distensibility after subcoronary stentless valve implantation.
Funder JA; Frost MW; Klaaborg KE; Wierup P; Hjortdal V; Nygaard H; Hasenkam JM
J Heart Valve Dis; 2012 Mar; 21(2):181-8. PubMed ID: 22645853
[TBL] [Abstract][Full Text] [Related]
29. Implantation of aortic stentless bioprosthesis: case series.
Sutlić Z; Unić D; Rudez I; Biocina B; Barić D; Kontić M
Croat Med J; 2002 Dec; 43(6):649-51. PubMed ID: 12476470
[TBL] [Abstract][Full Text] [Related]
30. Autografts, homografts, and xenografts: overview on stentless aortic valve surgery.
Luciani GB; Santini F; Mazzucco A
J Cardiovasc Med (Hagerstown); 2007 Feb; 8(2):91-6. PubMed ID: 17299289
[TBL] [Abstract][Full Text] [Related]
31. Thrombocytopenia after aortic valve replacement with the Freedom Solo stentless bioprosthesis.
Yerebakan C; Kaminski A; Westphal B; Kundt G; Ugurlucan M; Steinhoff G; Liebold A
Interact Cardiovasc Thorac Surg; 2008 Aug; 7(4):616-20. PubMed ID: 18505752
[TBL] [Abstract][Full Text] [Related]
32. Transvalvular velocities after full aortic root replacement: results from a prospective randomized trial between the homograft and the Medtronic Freestyle bioprosthesis.
Melina G; Mitchell A; Amrani M; Khaghani A; Yacoub MH
J Heart Valve Dis; 2002 Jan; 11(1):54-8; discussion 58-9. PubMed ID: 11843506
[TBL] [Abstract][Full Text] [Related]
33. Aortic root replacement with a stentless bioprosthesis in osteogenesis imperfecta.
Wakiyama H; Okada Y; Kitamura A; Imai Y
J Heart Valve Dis; 2008 Mar; 17(2):197-9. PubMed ID: 18512491
[TBL] [Abstract][Full Text] [Related]
34. Clinical experience with the 3F stentless aortic bioprosthesis: one-year follow up.
Linneweber J; Kossagk C; Rogge ML; Dushe S; Dohmen P; Konertz W
J Heart Valve Dis; 2006 Jul; 15(4):545-8. PubMed ID: 16901052
[TBL] [Abstract][Full Text] [Related]
35. eComment: CorBeat trileaflet mechanical full-flow heart valve prosthesis versus native human aortic valves - evaluation of functional performance.
Bockeria LA; Fadeev A; Bockeria O; Makhachev O
Interact Cardiovasc Thorac Surg; 2009 May; 8(5):557. PubMed ID: 19380343
[No Abstract] [Full Text] [Related]
36. Aortic root replacement with a valved conduit containing a stented xenograft.
Gatti G; Benussi B; Pappalardo A; Zingone B
Eur J Cardiothorac Surg; 2008 Apr; 33(4):740-1. PubMed ID: 18262429
[TBL] [Abstract][Full Text] [Related]
37. Midterm results after aortic valve replacement with a stentless bioprosthesis aortic valve.
Martinovic I; Everlien M; Farah I; Wittlinger T; Knez I; Greve H; Vogt P
Ann Thorac Surg; 2005 Jul; 80(1):198-203. PubMed ID: 15975367
[TBL] [Abstract][Full Text] [Related]
38. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus.
Wagner IM; Eichinger WB; Bleiziffer S; Botzenhardt F; Gebauer I; Guenzinger R; Bauernschmitt R; Lange R
J Thorac Cardiovasc Surg; 2007 May; 133(5):1234-41. PubMed ID: 17467435
[TBL] [Abstract][Full Text] [Related]
39. Stentless bioprostheses in small aortic roots: impact of patient-prosthesis mismatch on survival and quality of life.
Ennker J; Rosendahl U; Albert A; Dumlu E; Ennker IC; Florath I
J Heart Valve Dis; 2005 Jul; 14(4):523-30. PubMed ID: 16116880
[TBL] [Abstract][Full Text] [Related]
40. Hemodynamic comparison of bioprostheses for complete supra-annular position in patients with small aortic annulus.
Botzenhardt F; Eichinger WB; Bleiziffer S; Guenzinger R; Wagner IM; Bauernschmitt R; Lange R
J Am Coll Cardiol; 2005 Jun; 45(12):2054-60. PubMed ID: 15963409
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]