99 related articles for article (PubMed ID: 1184609)
1. The influences of electrical potential and surface finish on the fatigue life of surgical implant materials. Bapna MS; Lautenschlager EP; Moser JB J Biomed Mater Res; 1975 Nov; 9(6):611-21. PubMed ID: 1184609 [TBL] [Abstract][Full Text] [Related]
2. The influence of static stress on the corrosion behavior of 316L stainless steel in Ringer's solution. Bundy KJ; Vogelbaum MA; Desai VH J Biomed Mater Res; 1986 Apr; 20(4):493-505. PubMed ID: 3700443 [TBL] [Abstract][Full Text] [Related]
3. An in vitro investigation of the anodic polarization and capacitance behavior of 316-L stainless steel. Sutow EJ; Pollack SR; Korostoff E J Biomed Mater Res; 1976 Sep; 10(5):671-93. PubMed ID: 10307 [TBL] [Abstract][Full Text] [Related]
4. Corrosion fatigue of surgical stainless steel in synthetic physiological solution. Cahoon JR; Holte RN J Biomed Mater Res; 1981 Mar; 15(2):137-45. PubMed ID: 7348709 [TBL] [Abstract][Full Text] [Related]
5. Influence of the height of the external hexagon and surface treatment on fatigue life of commercially pure titanium dental implants. Gil FJ; Aparicio C; Manero JM; Padros A Int J Oral Maxillofac Implants; 2009; 24(4):583-90. PubMed ID: 19885397 [TBL] [Abstract][Full Text] [Related]
6. Flame-sprayed alumina on stainless steel for possible prosthetic application. Baldwin CM; Mackenzie JD J Biomed Mater Res; 1976 May; 10(3):445-53. PubMed ID: 1270460 [TBL] [Abstract][Full Text] [Related]
7. Biomechanical assessment of titanium and stainless steel posterior spinal constructs: effects of absolute/relative loading and frequency on fatigue life and determination of failure modes. Stambough JL; Genaidy AM; Huston RL; Serhan H; El-khatib F; Sabri EH J Spinal Disord; 1997 Dec; 10(6):473-81. PubMed ID: 9438811 [TBL] [Abstract][Full Text] [Related]
8. The corrosion fatigue properties of surgical implants in a living body. Morita M; Sasada T; Hayashi H; Tsukamoto Y J Biomed Mater Res; 1988 Jun; 22(6):529-40. PubMed ID: 3410871 [TBL] [Abstract][Full Text] [Related]
10. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials. Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246 [TBL] [Abstract][Full Text] [Related]
11. Polarization studies of surgical materials in Ringer's solution. Mueller HJ; Greener EH J Biomed Mater Res; 1970 Mar; 4(1):29-41. PubMed ID: 5434814 [No Abstract] [Full Text] [Related]
12. Influence of oxidation treatment on fatigue and fatigue-induced damage of commercially pure titanium. Leinenbach C; Eifler D Acta Biomater; 2009 Sep; 5(7):2810-9. PubMed ID: 19394905 [TBL] [Abstract][Full Text] [Related]
13. In vitro corrosion fatigue of 316L cold worked stainless steel. Taira M; Lautenschlager EP J Biomed Mater Res; 1992 Sep; 26(9):1131-9. PubMed ID: 1429762 [TBL] [Abstract][Full Text] [Related]
14. The influence of electropolishing on the corrosion resistance of 316L stainless steel. Sutow EJ J Biomed Mater Res; 1980 Sep; 14(5):587-95. PubMed ID: 7349665 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of the soft tissue interface at titanium implants with different surface treatments: experimental study on rabbits. Ungersböck A; Pohler O; Perren SM Biomed Mater Eng; 1994; 4(4):317-25. PubMed ID: 7950879 [TBL] [Abstract][Full Text] [Related]
16. Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern? Serhan H; Slivka M; Albert T; Kwak SD Spine J; 2004; 4(4):379-87. PubMed ID: 15246296 [TBL] [Abstract][Full Text] [Related]
17. Effect of surface treatments on the fatigue life of titanium for biomedical applications. Pazos L; Corengia P; Svoboda H J Mech Behav Biomed Mater; 2010 Aug; 3(6):416-24. PubMed ID: 20621024 [TBL] [Abstract][Full Text] [Related]