These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 11846910)

  • 1. The Camino intracranial pressure sensor: is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies.
    Piper I; Barnes A; Smith D; Dunn L
    Neurosurgery; 2001 Nov; 49(5):1158-64; discussion 1164-5. PubMed ID: 11846910
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Camino intracranial pressure device in clinical practice: reliability, handling characteristics and complications.
    Münch E; Weigel R; Schmiedek P; Schürer L
    Acta Neurochir (Wien); 1998; 140(11):1113-9; discussion 1119-20. PubMed ID: 9870055
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical evaluation of the Codman microsensor intracranial pressure monitoring system.
    Fernandes HM; Bingham K; Chambers IR; Mendelow AD
    Acta Neurochir Suppl; 1998; 71():44-6. PubMed ID: 9779140
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical evaluation of a new intracranial pressure monitoring device.
    Stendel R; Heidenreich J; Schilling A; Akhavan-Sigari R; Kurth R; Picht T; Pietilä T; Suess O; Kern C; Meisel J; Brock M
    Acta Neurochir (Wien); 2003 Mar; 145(3):185-93; discussion 193. PubMed ID: 12632114
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of zero drift in the Codman intracranial pressure monitor: a study from 2 neurointensive care units.
    Al-Tamimi YZ; Helmy A; Bavetta S; Price SJ
    Neurosurgery; 2009 Jan; 64(1):94-8; discussion 98-9. PubMed ID: 19145157
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases.
    Gelabert-González M; Ginesta-Galan V; Sernamito-García R; Allut AG; Bandin-Diéguez J; Rumbo RM
    Acta Neurochir (Wien); 2006 Apr; 148(4):435-41. PubMed ID: 16374566
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bench test assessment of the new Raumedic Neurovent-P ICP sensor: a technical report by the BrainIT group.
    Citerio G; Piper I; Cormio M; Galli D; Cazzaniga S; Enblad P; Nilsson P; Contant C; Chambers I;
    Acta Neurochir (Wien); 2004 Nov; 146(11):1221-6. PubMed ID: 15338335
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fiberoptic intraparenchymal brain pressure monitoring with the Camino V420 monitor: reflections on our experience in 163 severely head-injured patients.
    Poca MA; Sahuquillo J; Arribas M; Báguena M; Amorós S; Rubio E
    J Neurotrauma; 2002 Apr; 19(4):439-48. PubMed ID: 11990350
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Methods of experimental and clinical assessment of the relative measurement accuracy of an intracranial pressure transducer. Technical note.
    Morgalla MH; Krasznai L; Dietz K; Mettenleiter H; Deininger M; Grote EH
    J Neurosurg; 2001 Sep; 95(3):529-32. PubMed ID: 11565881
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of Intracranial Pressure Monitoring-Single Centre Observational Study and Literature Review.
    Pelah AI; Zakrzewska A; Calviello LA; Forcht Dagi T; Czosnyka Z; Czosnyka M
    Sensors (Basel); 2023 Mar; 23(7):. PubMed ID: 37050457
    [TBL] [Abstract][Full Text] [Related]  

  • 11. ICP measurement accuracy: the effect of temperature drift. Design of a laboratory test for assessment of ICP transducers.
    Morgalla MH; Mettenleiter H; Katzenberger T
    J Med Eng Technol; 1999; 23(1):10-4. PubMed ID: 10202697
    [TBL] [Abstract][Full Text] [Related]  

  • 12. ICP measurement control: laboratory test of 7 types of intracranial pressure transducers.
    Morgalla MH; Mettenleiter H; Bitzer M; Fretschner R; Grote EH
    J Med Eng Technol; 1999; 23(4):144-51. PubMed ID: 10561825
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Laboratory testing of three intracranial pressure microtransducers: technical report.
    Czosnyka M; Czosnyka Z; Pickard JD
    Neurosurgery; 1996 Jan; 38(1):219-24. PubMed ID: 8747977
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of simultaneous continuous intracranial pressure (ICP) signals from a Codman and a Camino ICP sensor.
    Eide PK
    Med Eng Phys; 2006 Jul; 28(6):542-9. PubMed ID: 16253539
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Post-monitoring changes in zero drift of "Codman" intracranial pressure sensors].
    Oshorov AV; Savin IA; Goriachev KA; Popugaev KA; Polupan AA; Sychev AA; Tabasaranskiĭ TF
    Anesteziol Reanimatol; 2011; (3):62-6. PubMed ID: 21851026
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The problem of long-term ICP drift assessment: improvement by use of the ICP drift index.
    Morgalla MH; Dietz K; Deininger M; Grote EH
    Acta Neurochir (Wien); 2002 Jan; 144(1):57-60; discussion 60-1. PubMed ID: 11807647
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Camino intracranial pressure monitor: prospective study of accuracy and complications.
    Martínez-Mañas RM; Santamarta D; de Campos JM; Ferrer E
    J Neurol Neurosurg Psychiatry; 2000 Jul; 69(1):82-6. PubMed ID: 10864608
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical experience with the intraparenchymal intracranial pressure monitoring Codman MicroSensor system.
    Koskinen LO; Olivecrona M
    Neurosurgery; 2005 Apr; 56(4):693-8; discussion 693-8. PubMed ID: 15792507
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Noninvasive intracranial compliance monitoring. Technical note and clinical results.
    Lang EW; Paulat K; Witte C; Zolondz J; Mehdorn HM
    J Neurosurg; 2003 Jan; 98(1):214-8. PubMed ID: 12546376
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Deciding on Appropriate Telemetric Intracranial Pressure Monitoring System.
    Norager NH; Lilja-Cyron A; Hansen TS; Juhler M
    World Neurosurg; 2019 Jun; 126():564-569. PubMed ID: 30898734
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.