These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 11848123)

  • 1. Preliminary study on extremely small angle x-ray scatter imaging with synchrotron radiation.
    Olivo A; Arfelli F; Dreossi D; Longo R; Menk RH; Pani S; Poropat P; Rigon L; Zanconati F; Castelli E
    Phys Med Biol; 2002 Feb; 47(3):469-80. PubMed ID: 11848123
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Maximum-likelihood estimation of scatter components algorithm for x-ray coherent scatter computed tomography of the breast.
    Ghammraoui B; Badal A; Popescu LM
    Phys Med Biol; 2016 Apr; 61(8):3164-79. PubMed ID: 27025665
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A theoretical study on phase-contrast mammography with Thomson-scattering x-ray sources.
    De Caro L; Giannini C; Bellotti R; Tangaro S
    Med Phys; 2009 Oct; 36(10):4644-53. PubMed ID: 19928096
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Synchrotron-based scattered radiation from phantom materials used in X-ray CT.
    Rao DV; Swapna M; Cesareo R; Brunetti A; Akatsuka T; Yuasa T; Takeda T; Gigante GE
    J Xray Sci Technol; 2010; 18(3):327-37. PubMed ID: 20714090
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.
    Liu X; Shaw CC
    Med Phys; 2007 Jul; 34(7):2718-29. PubMed ID: 17821980
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter.
    Harty PD; Lye JE; Ramanathan G; Butler DJ; Hall CJ; Stevenson AW; Johnston PN
    Med Phys; 2014 May; 41(5):052101. PubMed ID: 24784390
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Objective comparison of image quality and dose between conventional and synchrotron radiation mammography.
    Moeckli R; Verdun FR; Fiedler S; Pachoud M; Schnyder P; Valley JF
    Phys Med Biol; 2000 Dec; 45(12):3509-23. PubMed ID: 11131181
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Head scatter off-axis for megavoltage x rays.
    Zhu TC; Bjärngard BE
    Med Phys; 2003 Apr; 30(4):533-43. PubMed ID: 12722805
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Synchrotron-based coherent scatter x-ray projection imaging using an array of monoenergetic pencil beams.
    Landheer K; Johns PC
    Rev Sci Instrum; 2012 Sep; 83(9):095114. PubMed ID: 23020426
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT).
    Jin JY; Ren L; Liu Q; Kim J; Wen N; Guan H; Movsas B; Chetty IJ
    Med Phys; 2010 Nov; 37(11):5634-44. PubMed ID: 21158275
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measuring scatter radiation in diagnostic X rays for radiation protection purposes.
    Vlachos I; Tsantilas X; Kalyvas N; Delis H; Kandarakis I; Panayiotakis G
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):382-5. PubMed ID: 25911405
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of X-ray speckle-based imaging deflection retrieval algorithms for the optimization of radiation dose.
    Rouge-Labriet H; Quenot L; Bohic S; Fayard B; Paganin DM; Brun E; Berujon S
    Phys Med Biol; 2021 Mar; 66(6):065005. PubMed ID: 32268312
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simple dose rate measurements for a very high synchrotron X-ray flux.
    Liu CJ; Wang CH; Wang CL; Hwu Y; Lin CY; Margaritondo G
    J Synchrotron Radiat; 2009 May; 16(Pt 3):395-7. PubMed ID: 19395805
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Strategies for scatter correction in dual source CT.
    Petersilka M; Stierstorfer K; Bruder H; Flohr T
    Med Phys; 2010 Nov; 37(11):5971-92. PubMed ID: 21158310
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Photon scatter in portal images: accuracy of a fluence based pencil beam superposition algorithm.
    McCurdy BM; Pistorius S
    Med Phys; 2000 May; 27(5):913-22. PubMed ID: 10841394
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Estimating head and neck tissue dose from x-ray scatter to physicians performing x-ray guided cardiovascular procedures: a phantom study.
    Fetterly KA; Schueler BA; Grams MP; Sturchio GM
    J Radiol Prot; 2017 Mar; 37(1):43-58. PubMed ID: 27941226
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of the diagnostic radiological index of protection to protective garments.
    Pasciak AS; Jones AK; Wagner LK
    Med Phys; 2015 Feb; 42(2):653-662. PubMed ID: 28102605
    [TBL] [Abstract][Full Text] [Related]  

  • 18. First experiments on the Australian Synchrotron Imaging and Medical beamline, including investigations of the effective source size in respect of X-ray imaging.
    Stevenson AW; Mayo SC; Häusermann D; Maksimenko A; Garrett RF; Hall CJ; Wilkins SW; Lewis RA; Myers DE
    J Synchrotron Radiat; 2010 Jan; 17(1):75-80. PubMed ID: 20029114
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new method for studying sub-pulse dynamics at synchrotron sources.
    Wingert J; Singer A; Shpyrko OG
    J Synchrotron Radiat; 2015 Sep; 22(5):1141-6. PubMed ID: 26289263
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Verification of TG-61 dose for synchrotron-produced monochromatic x-ray beams using fluence-normalized MCNP5 calculations.
    Brown TA; Hogstrom KR; Alvarez D; Matthews KL; Ham K
    Med Phys; 2012 Dec; 39(12):7462-9. PubMed ID: 23231295
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.