These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

220 related articles for article (PubMed ID: 11848385)

  • 21. Friction and lubrication in cushion form bearings for artificial hip joints.
    Auger DD; Dowson D; Fisher J; Jin ZM
    Proc Inst Mech Eng H; 1993; 207(1):25-33. PubMed ID: 8363695
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Contact mechanics of metal-on-metal hip implants employing a metallic cup with a UHMWPE backing.
    Liu F; Jin ZM; Grigoris P; Hirt F; Rieker C
    Proc Inst Mech Eng H; 2003; 217(3):207-13. PubMed ID: 12807161
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of simplifications of bone and components inclination on the elastohydrodynamic lubrication modeling of metal-on-metal hip resurfacing prosthesis.
    Meng Q; Liu F; Fisher J; Jin Z
    Proc Inst Mech Eng H; 2013 May; 227(5):523-34. PubMed ID: 23637262
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Kinematics of the MATCO hip simulator and issues related to wear testing of metal-metal implants.
    Medley JB; Krygier JJ; Bobyn JD; Chan FW; Lippincott A; Tanzer M
    Proc Inst Mech Eng H; 1997; 211(1):89-99. PubMed ID: 9141894
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A 3D-transient elastohydrodynamic lubrication hip implant model to compare ultra high molecular weight polyethylene with more compliant polycarbonate polyurethane acetabular cups.
    Ford A; Hua Z; Ferguson SJ; Pruitt LA; Gao L
    J Mech Behav Biomed Mater; 2021 Jul; 119():104472. PubMed ID: 33813334
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Analysis of mixed lubrication mechanism in metal-on-metal hip joint replacements.
    Jin ZM
    Proc Inst Mech Eng H; 2002; 216(1):85-9. PubMed ID: 11905562
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Compliant layer acetabular cups: friction testing of a range of materials and designs for a new generation of prosthesis that mimics the natural joint.
    Scholes SC; Burgess IC; Marsden HR; Unsworth A; Jones E; Smith N
    Proc Inst Mech Eng H; 2006 Jul; 220(5):583-96. PubMed ID: 16898216
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Contact mechanics analysis of metal-on-metal hip resurfacing prostheses.
    Udofia IJ; Yew A; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(5):293-305. PubMed ID: 15532995
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Calculation of theoretical lubrication regimes in two-piece first metatarsophalangeal prostheses.
    Joyce TJ
    Biomed Mater Eng; 2008; 18(1):45-51. PubMed ID: 18198406
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Appropriate radial clearance of ceramic-on-ceramic total hip prostheses to realize squeeze-film lubrication.
    Mabuchi K; Sakai R; Ota M; Ujihira M
    Clin Biomech (Bristol, Avon); 2004 May; 19(4):362-9. PubMed ID: 15109756
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of gap outside contact area on lubrication of metal-on-Metal total hip replacement.
    Al-Saffar AA; Evans SL
    Comput Methods Biomech Biomed Engin; 2020 Aug; 23(11):675-689. PubMed ID: 32396392
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Tribological principles in metal-on-metal hip joint design.
    Dowson D
    Proc Inst Mech Eng H; 2006 Feb; 220(2):161-71. PubMed ID: 16669384
    [TBL] [Abstract][Full Text] [Related]  

  • 33. An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements.
    Jin ZM; Heng SM; Ng HW; Auger DD
    Proc Inst Mech Eng H; 1999; 213(4):317-27. PubMed ID: 10466363
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement.
    Wang A; Essner A; Klein R
    Proc Inst Mech Eng H; 2001; 215(2):133-9. PubMed ID: 11382072
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Contact mechanics of a novel metal-on-metal total hip replacement.
    Besong AA; Lee R; Farrar R; Jin ZM
    Proc Inst Mech Eng H; 2001; 215(6):543-8. PubMed ID: 11848386
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.
    Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J
    Proc Inst Mech Eng H; 2003; 217(2):147-53. PubMed ID: 12666782
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Deformation of press-fitted metallic resurfacing cups. Part 2: Finite element simulation.
    Yew A; Jin ZM; Donn A; Morlock MM; Isaac G
    Proc Inst Mech Eng H; 2006 Feb; 220(2):311-9. PubMed ID: 16669397
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Determination of lubricating film thickness for permeable hydrogel and non-permeable polyurethane layers bonded to a rigid substrate with particular reference to cushion form hip joint replacements.
    McClure G; Jin ZM; Fisher J; Tighe BJ
    Proc Inst Mech Eng H; 1996; 210(2):89-93. PubMed ID: 8688121
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Deformation of press-fitted metallic resurfacing cups. Part 1: Experimental simulation.
    Lin ZM; Meakins S; Morlock MM; Parsons P; Hardaker C; Flett M; Isaac G
    Proc Inst Mech Eng H; 2006 Feb; 220(2):299-309. PubMed ID: 16669396
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Friction of composite cushion bearings for total knee joint replacements under adverse lubrication conditions.
    Stewart T; Jin ZM; Fisher J
    Proc Inst Mech Eng H; 1997; 211(6):451-65. PubMed ID: 9509883
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.