144 related articles for article (PubMed ID: 11849575)
1. Noninvasive intraoperative monitoring of carbon dioxide in children: endtidal versus transcutaneous techniques.
Nosovitch MA; Johnson JO; Tobias JD
Paediatr Anaesth; 2002 Jan; 12(1):48-52. PubMed ID: 11849575
[TBL] [Abstract][Full Text] [Related]
2. Non-invasive carbon dioxide monitoring in patients with cystic fibrosis during general anesthesia: end-tidal versus transcutaneous techniques.
May A; Humston C; Rice J; Nemastil CJ; Salvator A; Tobias J
J Anesth; 2020 Feb; 34(1):66-71. PubMed ID: 31701307
[TBL] [Abstract][Full Text] [Related]
3. Noninvasive carbon dioxide monitoring during neurosurgical procedures in adults: end-tidal versus transcutaneous techniques.
McBride DS; Johnson JO; Tobias JD
South Med J; 2002 Aug; 95(8):870-4. PubMed ID: 12190224
[TBL] [Abstract][Full Text] [Related]
4. The relation of lactate level and carbon dioxide pressure discrepancies between transcutaneous and arterial measurements.
Gürün Kaya A; Özpinar ŞN; Öz M; Erol S; Arslan F; Çiledağ A; Kaya A
Tuberk Toraks; 2024 Jun; 72(2):120-130. PubMed ID: 38869204
[TBL] [Abstract][Full Text] [Related]
5. Noninvasive monitoring of carbon dioxide during respiratory failure in toddlers and infants: end-tidal versus transcutaneous carbon dioxide.
Tobias JD; Meyer DJ
Anesth Analg; 1997 Jul; 85(1):55-8. PubMed ID: 9212122
[TBL] [Abstract][Full Text] [Related]
6. Comparison of ventilator-integrated end-tidal CO2 and transcutaneous CO2 monitoring in home-ventilated neuromuscular patients.
Orlikowski D; Prigent H; Ambrosi X; Vaugier I; Pottier S; Annane D; Lofaso F; Ogna A
Respir Med; 2016 Aug; 117():7-13. PubMed ID: 27492508
[TBL] [Abstract][Full Text] [Related]
7. Validation of transcutaneous carbon dioxide monitoring using an artificial lung during adult pulsatile cardiopulmonary bypass.
Garrison L; Riley JB; Wysocki S; Souai J; Julick H
Int J Artif Organs; 2022 Feb; 45(2):155-161. PubMed ID: 33427011
[TBL] [Abstract][Full Text] [Related]
8. End tidal carbon dioxide is as reliable as transcutaneous monitoring in ventilated postsurgical neonates.
Tingay DG; Mun KS; Perkins EJ
Arch Dis Child Fetal Neonatal Ed; 2013 Mar; 98(2):F161-4. PubMed ID: 22887048
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of a new combined SpO2/PtcCO2 sensor in anaesthetized paediatric patients.
Dullenkopf A; Bernardo SD; Berger F; Fasnacht M; Gerber AC; Weiss M
Paediatr Anaesth; 2003 Nov; 13(9):777-84. PubMed ID: 14617118
[TBL] [Abstract][Full Text] [Related]
10. Transcutaneous carbon dioxide measurements in fruits, vegetables and humans: A prospective observational study.
Sochet AA; Bessone SK; Parilla NW; Nakagawa TA
Eur J Anaesthesiol; 2019 Dec; 36(12):904-910. PubMed ID: 31464713
[TBL] [Abstract][Full Text] [Related]
11. Transcutaneous carbon dioxide monitoring during high-frequency oscillatory ventilation in infants and children.
Berkenbosch JW; Tobias JD
Crit Care Med; 2002 May; 30(5):1024-7. PubMed ID: 12006797
[TBL] [Abstract][Full Text] [Related]
12. The application of transcutaneous CO2 pressure monitoring in the anesthesia of obese patients undergoing laparoscopic bariatric surgery.
Liu S; Sun J; Chen X; Yu Y; Liu X; Liu C
PLoS One; 2014; 9(4):e91563. PubMed ID: 24699267
[TBL] [Abstract][Full Text] [Related]
13. The reliability of endtidal CO2 in spontaneously breathing children during anaesthesia with laryngeal mask airway, low flow, sevoflurane and caudal epidural.
Aasheim P; Fasting S; Mostad U; Aadahl P
Paediatr Anaesth; 2002 Jun; 12(5):438-41. PubMed ID: 12060331
[TBL] [Abstract][Full Text] [Related]
14. Transcutaneous versus blood carbon dioxide monitoring during acute noninvasive ventilation in the emergency department - a retrospective analysis.
Horvath CM; Brutsche MH; Baty F; Rüdiger JJ
Swiss Med Wkly; 2016; 146():w14373. PubMed ID: 27878795
[TBL] [Abstract][Full Text] [Related]
15. Noninvasive monitoring of carbon dioxide: a comparison of the partial pressure of transcutaneous and end-tidal carbon dioxide with the partial pressure of arterial carbon dioxide.
Phan CQ; Tremper KK; Lee SE; Barker SJ
J Clin Monit; 1987 Jul; 3(3):149-54. PubMed ID: 3612214
[TBL] [Abstract][Full Text] [Related]
16. Monitoring of carbon dioxide in ventilated neonates: a prospective observational study.
Werther T; Aichhorn L; Stellberg S; Cardona FS; Klebermass-Schrehof K; Berger A; Schmölzer GM; Wagner M
Arch Dis Child Fetal Neonatal Ed; 2022 May; 107(3):293-298. PubMed ID: 34344835
[TBL] [Abstract][Full Text] [Related]
17. Transcutaneous Carbon Dioxide Monitoring in Subjects With Acute Respiratory Failure and Severe Hypercapnia.
Ruiz Y; Farrero E; Córdoba A; González N; Dorca J; Prats E
Respir Care; 2016 Apr; 61(4):428-33. PubMed ID: 26786741
[TBL] [Abstract][Full Text] [Related]
18. Transcutaneous monitoring of partial pressure of carbon dioxide in the elderly patient: a prospective, clinical comparison with end-tidal monitoring.
Casati A; Squicciarini G; Malagutti G; Baciarello M; Putzu M; Fanelli A
J Clin Anesth; 2006 Sep; 18(6):436-40. PubMed ID: 16980160
[TBL] [Abstract][Full Text] [Related]
19. Transcutaneous carbon dioxide measurements in anesthetized apneic patients with BMI > 35 kg/m
Eley VA; Guy L; Woods C; Llewellyn S; Van Zundert AAJ
J Anesth; 2023 Dec; 37(6):971-975. PubMed ID: 37814088
[TBL] [Abstract][Full Text] [Related]
20. Transcutaneous monitors during one-lung ventilation: are they reliable?
Chung MR; Lichtor JL; Rangachari K; Roizen MF
J Cardiothorac Anesth; 1988 Jun; 2(3):313-9. PubMed ID: 17171866
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]