These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 11849575)

  • 21. A comparison of transcutaneous end-tidal and arterial measurements of carbon dioxide during general anaesthesia.
    Reid CW; Martineau RJ; Miller DR; Hull KA; Baines J; Sullivan PJ
    Can J Anaesth; 1992 Jan; 39(1):31-6. PubMed ID: 1733530
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of endtidal CO2 and arterial blood gas analysis in paediatric patients undergoing controlled ventilation with a laryngeal mask or a face mask.
    Ozlü O; Ocal T
    Paediatr Anaesth; 1999; 9(5):409-13. PubMed ID: 10447903
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [The accuracy of transcutaneous carbon dioxide monitoring during laparoscopic surgery].
    Nakamura A; Kanai M; Mizushima A; Katashima S; Miura K; Kawauchi Y; Kamiyama Y
    Masui; 2003 Aug; 52(8):846-51. PubMed ID: 13677274
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Noninvasive carbon dioxide monitoring in a porcine model of acute lung injury due to smoke inhalation and burns.
    Belenkiy S; Ivey KM; Batchinsky AI; Langer T; Necsoiu C; Baker W; Salinas J; Cancio LC
    Shock; 2013 Jun; 39(6):495-500. PubMed ID: 23572088
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Estimation of arterial carbon dioxide by end-tidal and transcutaneous PCO2 measurements in ventilated children.
    Sivan Y; Eldadah MK; Cheah TE; Newth CJ
    Pediatr Pulmonol; 1992 Mar; 12(3):153-7. PubMed ID: 1641271
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Accuracy of Transcutaneous Carbon Dioxide Levels in Comparison to Arterial Carbon Dioxide Levels in Critically Ill Children.
    Bhalla AK; Khemani RG; Hotz JC; Morzov RP; Newth CJ
    Respir Care; 2019 Feb; 64(2):201-208. PubMed ID: 30254042
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Carbon dioxide monitoring during laparoscopic-assisted bariatric surgery in severely obese patients: transcutaneous versus end-tidal techniques.
    Dion JM; McKee C; Tobias JD; Herz D; Sohner P; Teich S; Michalsky M
    J Clin Monit Comput; 2015 Feb; 29(1):183-6. PubMed ID: 24916514
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Superiority of transcutaneous CO2 over end-tidal CO2 measurement for monitoring respiratory failure in nonintubated patients: A pilot study.
    Lermuzeaux M; Meric H; Sauneuf B; Girard S; Normand H; Lofaso F; Terzi N
    J Crit Care; 2016 Feb; 31(1):150-6. PubMed ID: 26463320
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Validity of transcutaneous PCO2 in monitoring chronic hypoventilation treated with non-invasive ventilation.
    Aarrestad S; Tollefsen E; Kleiven AL; Qvarfort M; Janssens JP; Skjønsberg OH
    Respir Med; 2016 Mar; 112():112-8. PubMed ID: 26874895
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Transcutaneous PTCCO
    Spelten O; Fiedler F; Schier R; Wetsch WA; Hinkelbein J
    J Clin Monit Comput; 2017 Feb; 31(1):153-158. PubMed ID: 26628269
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Noninvasive carbon dioxide monitoring during one-lung ventilation: end-tidal versus transcutaneous techniques.
    Tobias JD
    J Cardiothorac Vasc Anesth; 2003 Jun; 17(3):306-8. PubMed ID: 12827576
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accuracy and precision of transcutaneous carbon dioxide monitoring: a systematic review and meta-analysis.
    Conway A; Tipton E; Liu WH; Conway Z; Soalheira K; Sutherland J; Fingleton J
    Thorax; 2019 Feb; 74(2):157-163. PubMed ID: 30209079
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Accuracy and Interpretation of Transcutaneous Carbon Dioxide Monitoring in Critically Ill Children.
    Setar L; Lee JG; Sanchez-Pinto LN; Coates BM
    Pediatr Crit Care Med; 2024 Jun; ():. PubMed ID: 38935571
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Arterial to end-tidal carbon dioxide difference in children undergoing mechanical ventilation of the lungs during general anaesthesia.
    Onodi C; Bühler PK; Thomas J; Schmitz A; Weiss M
    Anaesthesia; 2017 Nov; 72(11):1357-1364. PubMed ID: 28695980
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Alveolar ventilation in children during flexible bronchoscopy.
    Sadot E; Gut G; Sivan Y
    Pediatr Pulmonol; 2016 Nov; 51(11):1177-1182. PubMed ID: 27061285
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Validation of a new combined transcutaneous tcPCO
    van Wijk JJ; van Weteringen W; Hoeks SE; Staals LM
    Paediatr Anaesth; 2022 Mar; 32(3):429-435. PubMed ID: 34882905
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Transcutaneous carbon dioxide monitoring during diabetic ketoacidosis in children and adolescents.
    McBride ME; Berkenbosch JW; Tobias JD
    Paediatr Anaesth; 2004 Feb; 14(2):167-71. PubMed ID: 14962333
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Association of partial pressure of carbon dioxide in expired gas and arterial blood at three different ventilation states in apneic chickens (Gallus domesticus) during air sac insufflation anesthesia.
    Paré M; Ludders JW; Erb HN
    Vet Anaesth Analg; 2013 May; 40(3):245-56. PubMed ID: 23331534
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Benefits of Continuous Monitoring of PCO2 Obtained from a System Applied to Membrane Oxygenator Exhaustion of the Cardiopulmonary Bypass Circuit.
    Filho VADR; Oliveira EL; Scramim JF; Sanga MA; Santos MAD
    Rev Port Cir Cardiotorac Vasc; 2019; 26(3):205-208. PubMed ID: 31734972
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Noninvasive monitoring of end-tidal CO2 via nasal cannulas in spontaneously breathing children during the perioperative period.
    Tobias JD; Flanagan JF; Wheeler TJ; Garrett JS; Burney C
    Crit Care Med; 1994 Nov; 22(11):1805-8. PubMed ID: 7956285
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.