These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 11861940)

  • 1. Direct measurement of intratracheal pressure in pediatric respiratory monitoring.
    Sondergaard S; Karason S; Hanson A; Nilsson K; Hojer S; Lundin S; Stenqvist O
    Pediatr Res; 2002 Mar; 51(3):339-45. PubMed ID: 11861940
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Calculation of intratracheal airway pressure in ventilated neonatal piglets with endotracheal tube leaks.
    Nikischin W; Herber-Jonat S; von Bismarck P; Lange M; Grabitz R
    Crit Care Med; 2007 May; 35(5):1383-9. PubMed ID: 17414085
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of a fiberoptic system for airway pressure monitoring.
    Koska J; Kelley E; Banner MJ; Blanch P
    J Clin Monit; 1994 Jul; 10(4):247-50. PubMed ID: 7931455
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants-the impact of ventilator settings on tracheal pressure swings.
    Hentschel R; Buntzel J; Guttmann J; Schumann S
    Physiol Meas; 2011 Sep; 32(9):1439-51. PubMed ID: 21799238
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Direct tracheal airway pressure measurements are essential for safe and accurate dynamic monitoring of respiratory mechanics. A laboratory study.
    Kárason S; Søndergaard S; Lundin S; Wiklund J; Stenqvist O
    Acta Anaesthesiol Scand; 2001 Feb; 45(2):173-9. PubMed ID: 11167162
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Continuous monitoring of tracheal pressure including spot-check of endotracheal tube resistance.
    Haberthür C; Lichtwarck-Aschoff M; Guttmann J
    Technol Health Care; 2003; 11(6):413-24. PubMed ID: 14757920
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intratracheal pressure: a more accurate reflection of pulmonary airway pressure in pediatric patients with respiratory failure.
    Dela Cruz RH; Banner MJ; Weldon BC
    Pediatr Crit Care Med; 2005 Mar; 6(2):175-81. PubMed ID: 15730605
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of a gas leak around the endotracheal tube on the mean tracheal pressure during mechanical ventilation.
    Pérez Fontán JJ; Heldt GP; Gregory GA
    Am Rev Respir Dis; 1985 Aug; 132(2):339-42. PubMed ID: 4026056
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of Endotracheal Tube Size, Respiratory System Mechanics, and Ventilator Settings on Driving Pressure.
    Ilia S; van Schelven PD; Koopman AA; Blokpoel RGT; de Jager P; Burgerhof JGM; Markhorst DG; Kneyber MCJ
    Pediatr Crit Care Med; 2020 Jan; 21(1):e47-e51. PubMed ID: 31688716
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A fibre optics system for the evaluation of airway pressure in mechanically ventilated patients.
    De Blasi RA; Conti G; Antonelli M; Bufi M; Gasparetto A
    Intensive Care Med; 1992; 18(7):405-9. PubMed ID: 1469178
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Alveolar pressure monitoring: an evaluation in a lung model and in patients with acute lung injury.
    Sondergaard S; Kárason S; Wiklund J; Lundin S; Stenqvist O
    Intensive Care Med; 2003 Jun; 29(6):955-962. PubMed ID: 12690438
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Relationship of neonatal endotracheal tube size and airway resistance.
    Oca MJ; Becker MA; Dechert RE; Donn SM
    Respir Care; 2002 Sep; 47(9):994-7. PubMed ID: 12188933
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Tracheal gas insufflation as a lung-protective strategy: physiologic, histologic, and biochemical markers.
    Oliver RE; Rozycki HJ; Greenspan JS; Wolfson MR; Shaffer TH
    Pediatr Crit Care Med; 2005 Jan; 6(1):64-9. PubMed ID: 15636662
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reduction in tracheal lumen due to endotracheal intubation and its calculated clinical significance.
    Bock KR; Silver P; Rom M; Sagy M
    Chest; 2000 Aug; 118(2):468-72. PubMed ID: 10936142
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An expiratory assist during spontaneous breathing can compensate for endotracheal tube resistance.
    Uchiyama A; Chang C; Suzuki S; Mashimo T; Fujino Y
    Anesth Analg; 2009 Aug; 109(2):434-40. PubMed ID: 19608814
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Gas flow between coaxial tubes: impedance to gas flow in an endotracheal tube increases with a catheter within.
    Magee PT
    Proc Inst Mech Eng H; 2012 Jun; 226(6):491-4. PubMed ID: 22783765
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of changes in respiratory mechanics during partial liquid ventilation using jet pulses.
    Schmalisch G; Schmidt M; Proquitté H; Foitzik B; Rüdiger M; Wauer RR
    Crit Care Med; 2003 May; 31(5):1435-41. PubMed ID: 12771615
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Correction of compliance and resistance altered by endotracheal tube leaks.
    Nikischin W; Lange M
    Pediatr Crit Care Med; 2003 Jul; 4(3):344-52. PubMed ID: 12831418
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of respiratory impedance by impulse oscillometry--effects of endotracheal tubes.
    Kuhnle GE; Brandt T; Roth U; Goetz AE; Smith HJ; Peter K
    Res Exp Med (Berl); 2000 Dec; 200(1):17-26. PubMed ID: 11197918
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Continuous calculation of intratracheal pressure in the presence of pediatric endotracheal tubes.
    Guttmann J; Kessler V; Mols G; Hentschel R; Haberthür C; Geiger K
    Crit Care Med; 2000 Apr; 28(4):1018-26. PubMed ID: 10809276
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.