203 related articles for article (PubMed ID: 11872016)
1. Impeller inner diameter in a miniaturized centrifugal blood pump.
Takano T; Schulte-Eistrup S; Kawahito S; Maeda T; Nonaka K; Linneweber J; Glueck J; Fujisawa A; Makinouchi K; Yokokawa M; Nosé Y
Artif Organs; 2002 Jan; 26(1):67-71. PubMed ID: 11872016
[TBL] [Abstract][Full Text] [Related]
2. Impeller design for a miniaturized centrifugal blood pump.
Takano T; Schulte-Eistrup S; Yoshikawa M; Nakata K; Kawahito S; Maeda T; Nonaka K; Linneweber J; Glueck J; Fujisawa A; Makinouchi K; Yokokawa M; Nosé Y
Artif Organs; 2000 Oct; 24(10):821-5. PubMed ID: 11091172
[TBL] [Abstract][Full Text] [Related]
3. Inlet port positioning for a miniaturized centrifugal blood pump.
Takano T; Schulte-Eistrup S; Kawahito S; Maeda T; Nonaka K; Linneweber J; Glueck J; Fujisawa A; Makinouchi K; Yokokawa M; Nosé Y
Artif Organs; 2002 Jan; 26(1):45-8. PubMed ID: 11872011
[TBL] [Abstract][Full Text] [Related]
4. Effect of surface roughness on hemolysis in a centrifugal blood pump.
Takami Y; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
ASAIO J; 1996; 42(5):M858-62. PubMed ID: 8945006
[TBL] [Abstract][Full Text] [Related]
5. Feasibility of a miniature centrifugal rotary blood pump for low-flow circulation in children and infants.
Takatani S; Hoshi H; Tajima K; Ohuchi K; Nakamura M; Asama J; Shimshi T; Yoshikawa M
ASAIO J; 2005; 51(5):557-62. PubMed ID: 16322718
[TBL] [Abstract][Full Text] [Related]
6. Effect of surface roughness on hemolysis in a pivot bearing supported Gyro centrifugal pump (C1E3).
Takami Y; Makinouchi K; Nakazawa T; Glueck J; Benkowski R; Nosé Y
Artif Organs; 1996 Nov; 20(11):1155-61. PubMed ID: 8908324
[TBL] [Abstract][Full Text] [Related]
7. The effect of the impeller-driver magnetic coupling distance on hemolysis in a compact centrifugal pump.
Nakazawa T; Makinouchi K; Takami Y; Glueck J; Takatani S; Nosé Y
Artif Organs; 1996 Mar; 20(3):252-7. PubMed ID: 8694696
[TBL] [Abstract][Full Text] [Related]
8. Feasibility of a tiny Gyro centrifugal pump as an implantable ventricular assist device.
Yoshikawa M; Nakata K; Ohtsuka G; Takano T; Glueck J; Fujisawa A; Makinouchi K; Yokokawa M; Nosé Y
Artif Organs; 1999 Aug; 23(8):774-9. PubMed ID: 10463506
[TBL] [Abstract][Full Text] [Related]
9. New centrifugal blood pump with dual impeller and double pivot bearing system: wear evaluation in bearing system, performance tests, and preliminary hemolysis tests.
Bock E; Ribeiro A; Silva M; Antunes P; Fonseca J; Legendre D; Leme J; Arruda C; Biscegli J; Nicolosi D; Andrade A
Artif Organs; 2008 Apr; 32(4):329-33. PubMed ID: 18370949
[TBL] [Abstract][Full Text] [Related]
10. Hemolytic effect of surface roughness of an impeller in a centrifugal blood pump.
Takami Y; Nakazawa T; Makinouchi K; Tayama E; Glueck J; Benkowski R; Nosé Y
Artif Organs; 1997 Jul; 21(7):686-90. PubMed ID: 9212939
[TBL] [Abstract][Full Text] [Related]
11. Modification of a pivot bearing system on a compact centrifugal pump.
Nakazawa T; Makinouchi K; Takami Y; Glueck J; Takatani S; Nosé Y
Artif Organs; 1996 Mar; 20(3):258-63. PubMed ID: 8694697
[TBL] [Abstract][Full Text] [Related]
12. In vivo evaluation of the "TinyPump" as a pediatric left ventricular assist device.
Kitao T; Ando Y; Yoshikawa M; Kobayashi M; Kimura T; Ohsawa H; Machida S; Yokoyama N; Sakota D; Konno T; Ishihara K; Takatani S
Artif Organs; 2011 May; 35(5):543-53. PubMed ID: 21595723
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of floating impeller phenomena in a Gyro centrifugal pump.
Nishimura I; Ichikawa S; Mikami M; Ishitoya H; Motomura T; Kawamura M; Linneweber J; Glueck J; Shinohara T; Nosé Y
Biomed Mater Eng; 2013; 23(1-2):49-55. PubMed ID: 23442236
[TBL] [Abstract][Full Text] [Related]
14. Hydraulic assessment of the floating impeller phenomena in a centrifugal pump.
Nakazawa T; Takami Y; Makinouchi K; Benkowski R; Glueck J; Damm G; Nosé Y
Artif Organs; 1997 Jan; 21(1):78-82. PubMed ID: 9012911
[TBL] [Abstract][Full Text] [Related]
15. Development of the Baylor/NASA axial flow ventricular assist device: in vitro performance and systematic hemolysis test results.
Mizuguchi K; Damm GA; Bozeman RJ; Akkerman JW; Aber GS; Svejkovsky PA; Bacak JW; Orime Y; Takatani S; Nosé Y
Artif Organs; 1994 Jan; 18(1):32-43. PubMed ID: 8141655
[TBL] [Abstract][Full Text] [Related]
16. Channel impeller design for centrifugal blood pump in hybrid pediatric total artificial heart: Modeling, magnet integration, and hydraulic experiments.
Hirschhorn M; Catucci N; Day SW; Stevens RM; Tchantchaleishvili V; Throckmorton AL
Artif Organs; 2023 Apr; 47(4):680-694. PubMed ID: 36524792
[TBL] [Abstract][Full Text] [Related]
17. Hemolytic effects of surface roughness of a pump housing in a centrifugal blood pump.
Takami Y; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
Artif Organs; 1997 May; 21(5):428-32. PubMed ID: 9129778
[TBL] [Abstract][Full Text] [Related]
18. The helical flow pump with a hydrodynamic levitation impeller.
Abe Y; Ishii K; Isoyama T; Saito I; Inoue Y; Ono T; Nakagawa H; Nakano E; Fukazawa K; Ishihara K; Fukunaga K; Ono M; Imachi K
J Artif Organs; 2012 Dec; 15(4):331-40. PubMed ID: 22926404
[TBL] [Abstract][Full Text] [Related]
19. Computational fluid dynamics analysis of the pediatric tiny centrifugal blood pump (TinyPump).
Kido K; Hoshi H; Watanabe N; Kataoka H; Ohuchi K; Asama J; Shinshi T; Yoshikawa M; Takatani S
Artif Organs; 2006 May; 30(5):392-9. PubMed ID: 16683958
[TBL] [Abstract][Full Text] [Related]
20. Effect of blade curvature on the hemolytic and hydraulic characteristics of a centrifugal blood pump.
Ozturk C; Aka IB; Lazoglu I
Int J Artif Organs; 2018 Nov; 41(11):730-737. PubMed ID: 29998774
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]