  • 1. Ventilatory failures with the Datex-Ohmeda 7900 SmartVent.
    Cantillo J; Domsky R; Gratz I; Goldberg ME
    Anesthesiology; 2002 Mar; 96(3):766-8. PubMed ID: 11873058
    [No Abstract]   [Full Text] [Related]  

  • 2. Ambient O.R. temperatures and Datex-Ohmeda 7900 SmartVent malfunction.
    Blinder JL
    Anesthesiology; 2002 Dec; 97(6):1645; author reply 1645. PubMed ID: 12459701
    [No Abstract]   [Full Text] [Related]  

  • 3. Failure of a flow sensor of a Datex Ohmeda S/5 Aespire.
    Snyders S
    Anaesthesia; 2005 Sep; 60(9):941; discussion 941-2. PubMed ID: 16115270
    [No Abstract]   [Full Text] [Related]  

  • 4. Inserting parameter modules upside down can cause shutdown of Datex-Ohmeda monitors.
    Health Devices; 2003 Dec; 32(12):483-5. PubMed ID: 14983564
    [No Abstract]   [Full Text] [Related]  

  • 5. Inadvertent development of subatmospheric airway pressure during cardiopulmonary bypass.
    Mushlin PS; Mark JB; Elliott WR; Striz S; Goldman DB; Philip J
    Anesthesiology; 1989 Sep; 71(3):459-62. PubMed ID: 2774278
    [No Abstract]   [Full Text] [Related]  

  • 6. Aestiva ventilation mode selector switch failures.
    Gravenstein D; Wilkhu H; Liem EB; Tilman S; Lampotang S
    Anesth Analg; 2007 Apr; 104(4):860-2. PubMed ID: 17377096
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Critical incident in relation to an anti-pollution system].
    Muñoz-Ramón JM; de la Cruz MT; Criado A
    Rev Esp Anestesiol Reanim; 1994; 41(1):43. PubMed ID: 8016432
    [No Abstract]   [Full Text] [Related]  

  • 8. Life-threatening bilateral pneumothorax caused by misconnection of the laser lens cooling system during gynecologic laparoscopy.
    Gueret G; Guischard F; Dumoulin JL; Oury JF; Mantz J; Desmonts JM
    Anesthesiology; 1999 Oct; 91(4):1179-80. PubMed ID: 10519526
    [No Abstract]   [Full Text] [Related]  

  • 9. Contemporary anesthesia ventilators incur a significant "oxygen cost".
    Klemenzson GK; Perouansky M
    Can J Anaesth; 2004; 51(6):616-20. PubMed ID: 15197125
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Intraoperative ventilatory obstruction by twisting of a reusable coiled expiratory breathing tube].
    Cuche H; Bientz J; Otteni JC
    Ann Fr Anesth Reanim; 2001 Jan; 20(1):54-6. PubMed ID: 11234581
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Displaced adjustable pressure limiting valve leaflet leading to partial expiratory obstruction in a cat.
    West E; Halil J
    Vet Anaesth Analg; 2019 Jan; 46(1):143-145. PubMed ID: 30528343
    [No Abstract]   [Full Text] [Related]  

  • 12. A hazard of silencers for jet ventilators.
    Van-Besouw JP
    Anaesthesia; 1987 Jan; 42(1):81. PubMed ID: 3469921
    [No Abstract]   [Full Text] [Related]  

  • 13. High end-expiratory airway pressures caused by internal obstruction of the Draeger Apollo® scavenger system that is not detected by the workstation self-test and visual inspection.
    Joyal JJ; Vannucci A; Kangrga I
    Anesthesiology; 2012 May; 116(5):1162-4; discussion 1164-6. PubMed ID: 22531265
    [No Abstract]   [Full Text] [Related]  

  • 14. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.
    Tung A; Drum ML; Morgan S
    J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Failure of an Ohmeda OAV 7750 ventilator.
    McKenna P; Foster WD; Dennis C
    Anaesthesia; 1992 Oct; 47(10):911-2. PubMed ID: 1443498
    [No Abstract]   [Full Text] [Related]  

  • 16. Unusual cause of leak in Datex Aisys.
    Kummar P; Korula G; Kumar S; Saravanan PA
    Anesth Analg; 2009 Oct; 109(4):1350-1; discussion 1351-2. PubMed ID: 19762773
    [No Abstract]   [Full Text] [Related]  

  • 17. Failure of datex AS/3 anaesthesia delivery unit.
    Aziz E; Sanders GM
    Anaesthesia; 2000 Dec; 55(12):1214-5. PubMed ID: 11121936
    [No Abstract]   [Full Text] [Related]  

  • 18. Leak on Datex Aestiva/5 anaesthetic machine.
    Aldridge J
    Anaesthesia; 2005 Apr; 60(4):420-1. PubMed ID: 15766359
    [No Abstract]   [Full Text] [Related]  

  • 19. Datex-Ohmeda S/5 Compact monitors can experience power supply failures at start-up and during operation.
    Health Devices; 2004 May; 33(5):176-8. PubMed ID: 15202337
    [No Abstract]   [Full Text] [Related]  

  • 20. Intraoperative Autotriggered Pressure Support Ventilation Resistant to Increased Flow Trigger Threshold.
    Benitez Lopez J; Rao SP; McNeer RR; Dudaryk R
    A A Case Rep; 2016 Jul; 7(1):9-12. PubMed ID: 27224041
    [TBL] [Abstract][Full Text] [Related]  