These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Failure of a flow sensor of a Datex Ohmeda S/5 Aespire. Snyders S Anaesthesia; 2005 Sep; 60(9):941; discussion 941-2. PubMed ID: 16115270 [No Abstract] [Full Text] [Related]
4. Inserting parameter modules upside down can cause shutdown of Datex-Ohmeda monitors. Health Devices; 2003 Dec; 32(12):483-5. PubMed ID: 14983564 [No Abstract] [Full Text] [Related]
5. Inadvertent development of subatmospheric airway pressure during cardiopulmonary bypass. Mushlin PS; Mark JB; Elliott WR; Striz S; Goldman DB; Philip J Anesthesiology; 1989 Sep; 71(3):459-62. PubMed ID: 2774278 [No Abstract] [Full Text] [Related]
7. [Critical incident in relation to an anti-pollution system]. Muñoz-Ramón JM; de la Cruz MT; Criado A Rev Esp Anestesiol Reanim; 1994; 41(1):43. PubMed ID: 8016432 [No Abstract] [Full Text] [Related]
8. Life-threatening bilateral pneumothorax caused by misconnection of the laser lens cooling system during gynecologic laparoscopy. Gueret G; Guischard F; Dumoulin JL; Oury JF; Mantz J; Desmonts JM Anesthesiology; 1999 Oct; 91(4):1179-80. PubMed ID: 10519526 [No Abstract] [Full Text] [Related]
9. Contemporary anesthesia ventilators incur a significant "oxygen cost". Klemenzson GK; Perouansky M Can J Anaesth; 2004; 51(6):616-20. PubMed ID: 15197125 [TBL] [Abstract][Full Text] [Related]
10. [Intraoperative ventilatory obstruction by twisting of a reusable coiled expiratory breathing tube]. Cuche H; Bientz J; Otteni JC Ann Fr Anesth Reanim; 2001 Jan; 20(1):54-6. PubMed ID: 11234581 [TBL] [Abstract][Full Text] [Related]
11. Displaced adjustable pressure limiting valve leaflet leading to partial expiratory obstruction in a cat. West E; Halil J Vet Anaesth Analg; 2019 Jan; 46(1):143-145. PubMed ID: 30528343 [No Abstract] [Full Text] [Related]
12. A hazard of silencers for jet ventilators. Van-Besouw JP Anaesthesia; 1987 Jan; 42(1):81. PubMed ID: 3469921 [No Abstract] [Full Text] [Related]
13. High end-expiratory airway pressures caused by internal obstruction of the Draeger Apollo® scavenger system that is not detected by the workstation self-test and visual inspection. Joyal JJ; Vannucci A; Kangrga I Anesthesiology; 2012 May; 116(5):1162-4; discussion 1164-6. PubMed ID: 22531265 [No Abstract] [Full Text] [Related]
14. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode. Tung A; Drum ML; Morgan S J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723 [TBL] [Abstract][Full Text] [Related]
15. Failure of an Ohmeda OAV 7750 ventilator. McKenna P; Foster WD; Dennis C Anaesthesia; 1992 Oct; 47(10):911-2. PubMed ID: 1443498 [No Abstract] [Full Text] [Related]
16. Unusual cause of leak in Datex Aisys. Kummar P; Korula G; Kumar S; Saravanan PA Anesth Analg; 2009 Oct; 109(4):1350-1; discussion 1351-2. PubMed ID: 19762773 [No Abstract] [Full Text] [Related]
17. Failure of datex AS/3 anaesthesia delivery unit. Aziz E; Sanders GM Anaesthesia; 2000 Dec; 55(12):1214-5. PubMed ID: 11121936 [No Abstract] [Full Text] [Related]
19. Datex-Ohmeda S/5 Compact monitors can experience power supply failures at start-up and during operation. Health Devices; 2004 May; 33(5):176-8. PubMed ID: 15202337 [No Abstract] [Full Text] [Related]
20. Intraoperative Autotriggered Pressure Support Ventilation Resistant to Increased Flow Trigger Threshold. Benitez Lopez J; Rao SP; McNeer RR; Dudaryk R A A Case Rep; 2016 Jul; 7(1):9-12. PubMed ID: 27224041 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]