These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 11875096)

  • 1. Thoracic duct injury associated with left internal jugular vein catheterization: anatomic considerations.
    Kwon SS; Falk A; Mitty HA
    J Vasc Interv Radiol; 2002 Mar; 13(3):337-9. PubMed ID: 11875096
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Traumatic chyle leak: a rare complication of left internal jugular venous cannulation.
    Jadhav AP; Stahlheber C; Hofmann H
    Am J Med Sci; 2011 Mar; 341(3):238-9. PubMed ID: 21289502
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrasound evaluation of the anatomical characteristics of the internal jugular vein and carotid artery--facilitation of internal jugular vein cannulation.
    Sibai AN; Loutfi E; Itani M; Baraka A
    Middle East J Anaesthesiol; 2008 Oct; 19(6):1305-20. PubMed ID: 18942245
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Is a neutral head position safer than 45-degree neck rotation during ultrasound-guided internal jugular vein cannulation? Results of a randomized controlled clinical trial.
    Lamperti M; Subert M; Cortellazzi P; Vailati D; Borrelli P; Montomoli C; D'Onofrio G; Caldiroli D
    Anesth Analg; 2012 Apr; 114(4):777-84. PubMed ID: 22253269
    [TBL] [Abstract][Full Text] [Related]  

  • 5. US-guided puncture of the internal jugular vein: complications and anatomic considerations.
    Gordon AC; Saliken JC; Johns D; Owen R; Gray RR
    J Vasc Interv Radiol; 1998; 9(2):333-8. PubMed ID: 9540919
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Relationship of the internal jugular vein to the common carotid artery: implications for ultrasound-guided vascular access.
    Maecken T; Marcon C; Bomas S; Zenz M; Grau T
    Eur J Anaesthesiol; 2011 May; 28(5):351-5. PubMed ID: 21150630
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of ultrasound guided brachiocephalic and internal jugular vein cannulation in critically ill children.
    Oulego-Erroz I; Muñoz-Lozón A; Alonso-Quintela P; Rodríguez-Nuñez A
    J Crit Care; 2016 Oct; 35():133-7. PubMed ID: 27481748
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrasound-guided external jugular vein cannulation for central venous access by inexperienced trainees.
    Mitre CI; Golea A; Acalovschi I; Mocan T; Caea AM; Ruţă C; Mariana M
    Eur J Anaesthesiol; 2010 Mar; 27(3):300-3. PubMed ID: 19935072
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biometric measurements involving the terminal portion of the thoracic duct on left cervical level IV: an anatomic study.
    Louzada AC; Lim SJ; Pallazzo JF; Silva VP; de Oliveira RV; Yoshio AM; de Araújo-Neto VJ; Leite AK; Silveira A; Simões C; Brandão LG; Matos LL; Cernea CR
    Anat Sci Int; 2016 Jun; 91(3):274-9. PubMed ID: 26272628
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Cannulation of the thoracic duct during central venous catheterization].
    Bosco M; Villani A; Prisco L; Rossi P
    Minerva Anestesiol; 1989; 55(7-8):325-8. PubMed ID: 2622546
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Competence of the internal jugular vein valve is damaged by cannulation and catheterization of the internal jugular vein.
    Wu X; Studer W; Erb T; Skarvan K; Seeberger MD
    Anesthesiology; 2000 Aug; 93(2):319-24. PubMed ID: 10910476
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The success rate and safety of internal jugular vein cannulation using anatomical landmark technique in patients undergoing cardiothoracic surgery.
    Tempe DK; Virmani S; Agarwal J; Hemrajani M; Satyarthy S; Minhas HS
    Ann Card Anaesth; 2013; 16(1):16-20. PubMed ID: 23287081
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Real-time ultrasound guided placement of temporary internal jugular vein catheters: assessment of technical success and complication rates in nephrology practice.
    Akoglu H; Piskinpasa S; Yenigun EC; Ozturk R; Dede F; Odabas AR
    Nephrology (Carlton); 2012 Sep; 17(7):603-6. PubMed ID: 22715902
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of the bevel direction of puncture needle on success rate and complications during internal jugular vein catheterization.
    Lim T; Ryu HG; Jung CW; Jeon Y; Bahk JH
    Crit Care Med; 2012 Feb; 40(2):491-4. PubMed ID: 21983370
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Anatomical variations of the internal jugular vein: implications for successful cannulation and risk of carotid artery puncture.
    Lorchirachoonkul T; Ti LK; Manohara S; Lye ST; Tan SA; Shen L; Kang DS
    Singapore Med J; 2012 May; 53(5):325-8. PubMed ID: 22584972
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultrasound monitoring in cannulation of the internal jugular vein: anatomic and technical considerations.
    Docktor B; So CB; Saliken JC; Gray RR
    Can Assoc Radiol J; 1996 Jun; 47(3):195-201. PubMed ID: 8640417
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultrasound-guided cannulation of the internal jugular vein in robotic cardiac surgery.
    Wang Y; Wang G; Gao CQ
    Chin Med J (Engl); 2013 Jul; 126(13):2414-7. PubMed ID: 23823810
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative Sonoanatomy of Classic "Short Axis" Probe Position with a Novel "Medial-oblique" Probe Position for Ultrasound-guided Internal Jugular Vein Cannulation: A Crossover Study.
    Baidya DK; Chandralekha ; Darlong V; Pandey R; Goswami D; Maitra S
    J Emerg Med; 2015 May; 48(5):590-6. PubMed ID: 25630474
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of an ultrasound-guided technique for central venous access via the internal jugular vein in 493 patients.
    Mey U; Glasmacher A; Hahn C; Gorschlüter M; Ziske C; Mergelsberg M; Sauerbruch T; Schmidt-Wolf IG
    Support Care Cancer; 2003 Mar; 11(3):148-55. PubMed ID: 12618924
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of optimized ultrasound axis along with marked introducer needle to prevent mechanical complications of internal jugular vein catheterization.
    Ghatak T; Singh RK; Baronia AK
    Ann Card Anaesth; 2013; 16(4):296-8. PubMed ID: 24107701
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.