3. [Development of a predictive MIMO regulator for heart-lung machines based on a model of extracorporeal circulation]. Schwarzhaupt A; Qaqunda B; Kiencke U Biomed Tech (Berl); 1998; 43 Suppl():336-7. PubMed ID: 9859386 [No Abstract] [Full Text] [Related]
4. Automation of a portable extracorporeal circulatory support system with adaptive fuzzy controllers. Mendoza García A; Krane M; Baumgartner B; Sprunk N; Schreiber U; Eichhorn S; Lange R; Knoll A Med Eng Phys; 2014 Aug; 36(8):981-90. PubMed ID: 24894032 [TBL] [Abstract][Full Text] [Related]
5. Virtual patient simulator for the perfusion resource management drill. Ninomiya S; Tokaji M; Tokumine A; Kurosaki T J Extra Corpor Technol; 2009 Dec; 41(4):206-12. PubMed ID: 20092074 [TBL] [Abstract][Full Text] [Related]
6. Use of an extracorporeal circulation perfusion simulator: evaluation of its accuracy and repeatability. Tokumine A; Momose N; Tomizawa Y J Artif Organs; 2013 Dec; 16(4):417-24. PubMed ID: 24022821 [TBL] [Abstract][Full Text] [Related]
7. Automatic modules for extracorporeal circulation control. Chauveau N; Van Meurs W; Barthelemy R; Morucci JP Int J Artif Organs; 1990 Oct; 13(10):692-6. PubMed ID: 2254047 [TBL] [Abstract][Full Text] [Related]
8. Hemodynamic analysis and design of a paracorporeal artificial lung device. Ha RR; Wang D; Zwischenberger JB; Clark JW Cardiovasc Eng; 2006 Mar; 6(1):10-29. PubMed ID: 16900418 [TBL] [Abstract][Full Text] [Related]
9. HeMoLab--Hemodynamics Modelling Laboratory: an application for modelling the human cardiovascular system. Larrabide I; Blanco PJ; Urquiza SA; Dari EA; Vénere MJ; de Souza e Silva NA; Feijóo RA Comput Biol Med; 2012 Oct; 42(10):993-1004. PubMed ID: 22964397 [TBL] [Abstract][Full Text] [Related]
10. A naturally shaped silicone ventricle evaluated in a mock circulation loop: a preliminary study. Gregory S; Timms D; Pearcy MJ; Tansley G J Med Eng Technol; 2009; 33(3):185-91. PubMed ID: 19340688 [TBL] [Abstract][Full Text] [Related]
13. [Signal analysis of the hemodynamics of extracorporeal circulation for the evaluation of patient status]. Schwarzhaupt A; Torkzadeh DD; Kiencke U Biomed Tech (Berl); 1999 May; 44(5):120-8. PubMed ID: 10413985 [TBL] [Abstract][Full Text] [Related]
14. Microcomputer-based automatic regulation of extracorporeal circulation: a trial for the application of fuzzy inference. Anbe J; Tobi T; Nakajima H; Akasaka T; Okinaga K Artif Organs; 1992 Oct; 16(5):532-8. PubMed ID: 10078307 [TBL] [Abstract][Full Text] [Related]
15. Total respiratory support with tidal flow extracorporeal circulation in adult sheep. Kolla S; Crotti S; Lee WA; Gargulinski MJ; Lewandowski T; Bach D; Hirschl RB; Bartlett RH ASAIO J; 1997; 43(5):M811-6. PubMed ID: 9360159 [TBL] [Abstract][Full Text] [Related]
16. A cardiovascular simulator tailored for training and clinical uses. Fresiello L; Ferrari G; Di Molfetta A; Zieliński K; Tzallas A; Jacobs S; Darowski M; Kozarski M; Meyns B; Katertsidis NS; Karvounis EC; Tsipouras MG; Trivella MG J Biomed Inform; 2015 Oct; 57():100-12. PubMed ID: 26173037 [TBL] [Abstract][Full Text] [Related]
17. [Characteristics of the use of the pulse system in artificial circulation units]. U'lianov NA; Radionova LN Med Tekh; 1989; (1):26-30. PubMed ID: 2739543 [TBL] [Abstract][Full Text] [Related]
18. The VIBE of the burning agents: simulation and modeling of burns and their treatment using agent-based programming, virtual reality, and human patient simulation. von Lubitz DK; Van Dyke Parunak H; Levine H; Beier KP; Freer J; Pletcher T; Sauter J; Treloar D; Wolf E Stud Health Technol Inform; 2001; 81():554-60. PubMed ID: 11317808 [No Abstract] [Full Text] [Related]
19. Interactive navigation and bronchial tube tracking in virtual bronchoscopy. Heng PA; Fung PF; Wong TT; Siu YH; Sun H Stud Health Technol Inform; 1999; 62():130-3. PubMed ID: 10538342 [TBL] [Abstract][Full Text] [Related]