These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
150 related articles for article (PubMed ID: 11880779)
1. Minimal versus maximal plate fixation techniques of the ulna: the biomechanical effect of number of screws and plate length. Sanders R; Haidukewych GJ; Milne T; Dennis J; Latta LL J Orthop Trauma; 2002 Mar; 16(3):166-71. PubMed ID: 11880779 [TBL] [Abstract][Full Text] [Related]
2. [Internal fixation of radial shaft fractures: Anatomical and biomechanical principles]. Bartoníček J; Naňka O; Tuček M Rozhl Chir; 2015 Oct; 94(10):425-36. PubMed ID: 26556020 [TBL] [Abstract][Full Text] [Related]
3. Locked versus unlocked plating with respect to plate length in an ulna fracture model. Weiss DB; Kaar SG; Frankenburg EP; Karunakar MA Bull NYU Hosp Jt Dis; 2008; 66(1):5-8. PubMed ID: 18333821 [TBL] [Abstract][Full Text] [Related]
4. Do Transcortical Screws in a Locking Plate Construct Improve the Stiffness in the Fixation of Vancouver B1 Periprosthetic Femur Fractures? A Biomechanical Analysis of 2 Different Plating Constructs. Lochab J; Carrothers A; Wong E; McLachlin S; Aldebeyan W; Jenkinson R; Whyne C; Nousiainen MT J Orthop Trauma; 2017 Jan; 31(1):15-20. PubMed ID: 28002219 [TBL] [Abstract][Full Text] [Related]
5. Comparison of crossed screw versus plate fixation for radial neck fractures. Gutowski CJ; Darvish K; Ilyas AM; Jones CM Clin Biomech (Bristol); 2015 Nov; 30(9):966-70. PubMed ID: 26184087 [TBL] [Abstract][Full Text] [Related]
6. Are locking screws advantageous with plate fixation of humeral shaft fractures? A biomechanical analysis of synthetic and cadaveric bone. O'Toole RV; Andersen RC; Vesnovsky O; Alexander M; Topoleski LD; Nascone JW; Sciadini MF; Turen C; Eglseder WA J Orthop Trauma; 2008; 22(10):709-15. PubMed ID: 18978547 [TBL] [Abstract][Full Text] [Related]
7. Can locking screws allow smaller, low-profile plates to achieve comparable stability to larger, standard plates? Garrigues GE; Glisson RR; Garrigues NW; Richard MJ; Ruch DS J Orthop Trauma; 2011 Jun; 25(6):347-54. PubMed ID: 21577070 [TBL] [Abstract][Full Text] [Related]
8. Schuhli augmentation of plate and screw fixation for humeral shaft fractures: a laboratory study. Simon JA; Dennis MG; Kummer FJ; Koval KJ J Orthop Trauma; 1999; 13(3):196-9. PubMed ID: 10206251 [TBL] [Abstract][Full Text] [Related]
9. Distal Ulna Fractures: A Biomechanical Comparison of Locking Versus Nonlocking Plating Constructs. Collins M; Hart A; Hines J; Steffen T; Harvey EJ; Martineau PA J Orthop Trauma; 2014 Aug; 28(8):470-5. PubMed ID: 24121982 [TBL] [Abstract][Full Text] [Related]
10. Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones. Gruszka D; Arand C; Greenfield J; Nowak TE; Kuechle R; Kuhn S; Rommens PM Arch Orthop Trauma Surg; 2017 Dec; 137(12):1651-1658. PubMed ID: 28864862 [TBL] [Abstract][Full Text] [Related]
11. A Biomechanical Comparison of Fifth Metatarsal Jones Fracture Fixation Methods. Duplantier NL; Mitchell RJ; Zambrano S; Stone AC; Delgado DA; Lambert BS; Moreno MR; Harris JD; McCulloch PC; Lintner DM; Varner KE Am J Sports Med; 2018 Apr; 46(5):1220-1227. PubMed ID: 29466679 [TBL] [Abstract][Full Text] [Related]
12. Locked plate fixation of osteoporotic humeral shaft fractures: are two locking screws per segment enough? Hak DJ; Althausen P; Hazelwood SJ J Orthop Trauma; 2010 Apr; 24(4):207-11. PubMed ID: 20335752 [TBL] [Abstract][Full Text] [Related]
13. [A biomechanical study on internal fixation of proximal ulna combined with olecranon fracture]. Teng L; Zhong G; Liu G; Xiao C; Liu G; Huang F Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2012 Jan; 26(1):10-3. PubMed ID: 22332509 [TBL] [Abstract][Full Text] [Related]
14. Plate selection for fixation of extra-articular distal humerus fractures: a biomechanical comparison of three different implants. Scolaro JA; Hsu JE; Svach DJ; Mehta S Injury; 2014 Dec; 45(12):2040-4. PubMed ID: 25249244 [TBL] [Abstract][Full Text] [Related]
15. A mechanical comparison of the locking compression plate (LCP) and the low contact-dynamic compression plate (DCP) in an osteoporotic bone model. Snow M; Thompson G; Turner PG J Orthop Trauma; 2008 Feb; 22(2):121-5. PubMed ID: 18349780 [TBL] [Abstract][Full Text] [Related]
16. Biomechanical comparison between double-plate fixation and posterior plate fixation for comminuted olecranon fracture using two triceps screws in synthetic bone model. Lee Y; Cho BW; Kim MB; Lee YH Medicine (Baltimore); 2022 Jan; 101(1):e28313. PubMed ID: 35029878 [TBL] [Abstract][Full Text] [Related]
17. The strength of plate fixation in relation to the number and spacing of bone screws. Törnkvist H; Hearn TC; Schatzker J J Orthop Trauma; 1996; 10(3):204-8. PubMed ID: 8667113 [TBL] [Abstract][Full Text] [Related]
18. Biomechanical comparison of fixation methods in transverse olecranon fractures: a cadaveric study. Prayson MJ; Williams JL; Marshall MP; Scilaris TA; Lingenfelter EJ J Orthop Trauma; 1997 Nov; 11(8):565-72. PubMed ID: 9415862 [TBL] [Abstract][Full Text] [Related]
19. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled? Stoffel K; Dieter U; Stachowiak G; Gächter A; Kuster MS Injury; 2003 Nov; 34 Suppl 2():B11-9. PubMed ID: 14580982 [TBL] [Abstract][Full Text] [Related]
20. An in vitro biomechanical comparison of hydroxyapatite coated and uncoated ao cortical bone screws for a limited contact: dynamic compression plate fixation of osteotomized equine 3rd metacarpal bones. Durham ME; Sod GA; Riggs LM; Mitchell CF Vet Surg; 2015 Feb; 44(2):206-13. PubMed ID: 25132492 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]