These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 11880834)

  • 21. A pedicle screw system and a lamina hook system provide similar primary and long-term stability: a biomechanical in vitro study with quasi-static and dynamic loading conditions.
    Wilke HJ; Kaiser D; Volkheimer D; Hackenbroch C; Püschel K; Rauschmann M
    Eur Spine J; 2016 Sep; 25(9):2919-28. PubMed ID: 27405823
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Polymethylmethacrylate augmentation of pedicle screws increases the initial fixation in osteoporotic spine patients.
    Sawakami K; Yamazaki A; Ishikawa S; Ito T; Watanabe K; Endo N
    J Spinal Disord Tech; 2012 Apr; 25(2):E28-35. PubMed ID: 22454185
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Biomechanical properties of threaded inserts for lumbar interbody spinal fusion.
    Tencer AF; Hampton D; Eddy S
    Spine (Phila Pa 1976); 1995 Nov; 20(22):2408-14. PubMed ID: 8578391
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Ceramic granules enhanced with B2A peptide for lumbar interbody spine fusion: an experimental study using an instrumented model in sheep.
    Cunningham BW; Atkinson BL; Hu N; Kikkawa J; Jenis L; Bryant J; Zamora PO; McAfee PC
    J Neurosurg Spine; 2009 Apr; 10(4):300-7. PubMed ID: 19441986
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Biomechanical comparison of cervical spine interbody fusion cages.
    Kandziora F; Pflugmacher R; Schäfer J; Born C; Duda G; Haas NP; Mittlmeier T
    Spine (Phila Pa 1976); 2001 Sep; 26(17):1850-7. PubMed ID: 11568693
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of the degree of osteoporosis on the biomechanical anchoring strength of the sacral pedicle screws: an in vitro comparison between unaugmented bicortical screws and polymethylmethacrylate augmented unicortical screws.
    Zhuang XM; Yu BS; Zheng ZM; Zhang JF; Lu WW
    Spine (Phila Pa 1976); 2010 Sep; 35(19):E925-31. PubMed ID: 20098349
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Strain distribution in the lumbar vertebrae under different loading configurations.
    Cristofolini L; Brandolini N; Danesi V; Juszczyk MM; Erani P; Viceconti M
    Spine J; 2013 Oct; 13(10):1281-92. PubMed ID: 23958297
    [TBL] [Abstract][Full Text] [Related]  

  • 28. New rod-plate anterior instrumentation for thoracolumbar/lumbar scoliosis: biomechanical evaluation compared with dual-rod and single-rod with structural interbody support.
    Zhang H; Johnston CE; Pierce WA; Ashman RB; Bronson DG; Haideri NF
    Spine (Phila Pa 1976); 2006 Dec; 31(25):E934-40. PubMed ID: 17139209
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Biomechanical comparison of spondylolysis fixation techniques.
    Deguchi M; Rapoff AJ; Zdeblick TA
    Spine (Phila Pa 1976); 1999 Feb; 24(4):328-33. PubMed ID: 10065515
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical Comparisons of Pull Out Strengths After Pedicle Screw Augmentation with Hydroxyapatite, Calcium Phosphate, or Polymethylmethacrylate in the Cadaveric Spine.
    Yi S; Rim DC; Park SW; Murovic JA; Lim J; Park J
    World Neurosurg; 2015 Jun; 83(6):976-81. PubMed ID: 25769482
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Biomechanical study and digital modeling of traction resistance in posterior thoracic implants].
    Gayet LE; Hamcha H; Charbonneau A; Texereau J; Bertheau D; Bellicaud D; Pries P
    Rev Chir Orthop Reparatrice Appar Mot; 2001 Sep; 87(5):459-68. PubMed ID: 11547233
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biomechanical analysis of pedicle screws in osteoporotic bone with bioactive cement augmentation using simulated in vivo multicomponent loading.
    Choma TJ; Frevert WF; Carson WL; Waters NP; Pfeiffer FM
    Spine (Phila Pa 1976); 2011 Mar; 36(6):454-62. PubMed ID: 20881517
    [TBL] [Abstract][Full Text] [Related]  

  • 33. An in Vitro Biomechanical Model of Differing Pedicle Screw Configurations for Long Construct Segmental Thoracic Fixation.
    Tuchman A; Turner AWL; Metzger MF; Acosta FL
    Oper Neurosurg (Hagerstown); 2017 Dec; 13(6):718-723. PubMed ID: 29186600
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Biomechanics of lateral plate and pedicle screw constructs in lumbar spines instrumented at two levels with laterally placed interbody cages.
    Nayak AN; Gutierrez S; Billys JB; Santoni BG; Castellvi AE
    Spine J; 2013 Oct; 13(10):1331-8. PubMed ID: 23685215
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Could junctional problems at the end of a long construct be addressed by providing a graduated reduction in stiffness? A biomechanical investigation.
    Durrani A; Jain V; Desai R; Bucklen B; Ingalhalikar A; Muzumdar A; Moldavsky M; Khalil S
    Spine (Phila Pa 1976); 2012 Jan; 37(1):E16-22. PubMed ID: 21540778
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Biomechanical evaluation of a novel fenestrated pedicle screw augmented with bone cement in osteoporotic spines.
    Paré PE; Chappuis JL; Rampersaud R; Agarwala AO; Perra JH; Erkan S; Wu C
    Spine (Phila Pa 1976); 2011 Aug; 36(18):E1210-4. PubMed ID: 21325986
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Real-time in vivo loading in the lumbar spine: part 1. Interbody implant: load cell design and preliminary results.
    Ledet EH; Sachs BL; Brunski JB; Gatto CE; Donzelli PS
    Spine (Phila Pa 1976); 2000 Oct; 25(20):2595-600. PubMed ID: 11034643
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biomechanical analysis of facet and graft loading in a Smith-Robinson type cervical spine model.
    Olsewski JM; Garvey TA; Schendel MJ
    Spine (Phila Pa 1976); 1994 Nov; 19(22):2540-4. PubMed ID: 7855678
    [TBL] [Abstract][Full Text] [Related]  

  • 39. In vitro disc pressure profiles below scoliosis fusion constructs.
    Buttermann GR; Beaubien BP
    Spine (Phila Pa 1976); 2008 Sep; 33(20):2134-42. PubMed ID: 18794754
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The effect of anterior thoracolumbar plate application on the compressive loading of the strut graft.
    Harris MB; Thomas KA; Igram CM; Bearden CM
    Spine (Phila Pa 1976); 1996 Jul; 21(13):1487-93. PubMed ID: 8817774
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.