These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

466 related articles for article (PubMed ID: 11900039)

  • 21. Comparative analysis of signal accuracy of three SpO
    Giuliano KK; Bilkovski RN; Beard J; Lamminmäki S
    J Clin Monit Comput; 2023 Dec; 37(6):1451-1461. PubMed ID: 37266709
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Importance of the pulse oximeter averaging time when measuring oxygen desaturation in sleep apnea.
    Farré R; Montserrat JM; Ballester E; Hernández L; Rotger M; Navajas D
    Sleep; 1998 Jun; 21(4):386-90. PubMed ID: 9646383
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Pulse oximetry: accuracy of methods of interpreting graphic summaries.
    Lafontaine VM; Ducharme FM; Brouillette RT
    Pediatr Pulmonol; 1996 Feb; 21(2):121-31. PubMed ID: 8882214
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Advanced pulse oximeter signal processing technology compared to simple averaging. II. Effect on frequency of alarms in the postanesthesia care unit.
    Rheineck-Leyssius AT; Kalkman CJ
    J Clin Anesth; 1999 May; 11(3):196-200. PubMed ID: 10434214
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A prototype device for standardized calibration of pulse oximeters II.
    Hornberger Ch; Knoop P; Matz H; Dörries F; Konecny E; Gehring H; Otten J; Bonk R; Frankenberger H; Wouters P; Gil-Rodriguez J; Ponz L; Avgerinos J; Karoutis A; Ikiades A; Weininger S
    J Clin Monit Comput; 2002; 17(3-4):203-9. PubMed ID: 12455737
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Advanced pulse oximeter signal processing technology compared to simple averaging. I. Effect on frequency of alarms in the operating room.
    Rheineck-Leyssius AT; Kalkman CJ
    J Clin Anesth; 1999 May; 11(3):192-5. PubMed ID: 10434213
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Pulse oximeters' reliability in detecting hypoxemia and bradycardia: comparison between a conventional and two new generation oximeters.
    Bohnhorst B; Peter CS; Poets CF
    Crit Care Med; 2000 May; 28(5):1565-8. PubMed ID: 10834712
    [TBL] [Abstract][Full Text] [Related]  

  • 28. False alarms and sensitivity of conventional pulse oximetry versus the Masimo SET technology in the pediatric postanesthesia care unit.
    Malviya S; Reynolds PI; Voepel-Lewis T; Siewert M; Watson D; Tait AR; Tremper K
    Anesth Analg; 2000 Jun; 90(6):1336-40. PubMed ID: 10825316
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A prospective comparison of 3 new-generation pulse oximetry devices during ambulation after open heart surgery.
    Richards NM; Giuliano KK; Jones PG
    Respir Care; 2006 Jan; 51(1):29-35. PubMed ID: 16381614
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Continuous pulse oximetry in the general surgical ward: Nellcor N-200 versus Nellcor N-3000.
    Christensen M; Lie C; Rosenberg J
    Anaesthesia; 1999 Mar; 54(3):253-7. PubMed ID: 10364861
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Next-generation pulse oximetry. Focusing on Masimo's signal extraction technology.
    Health Devices; 2000 Oct; 29(10):349-70. PubMed ID: 11094776
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Simultaneous comparison of three noninvasive oximeters in healthy volunteers.
    Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM
    Med Instrum; 1987 Jun; 21(3):183-8. PubMed ID: 3614041
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Pulse oximetry in newborn infants with birth weights of 620 to 4285 grams receiving dopamine and dobutamine.
    Sardesai S; Durand M; McEvoy C; Johnson C; Maarek JM
    J Perinatol; 1996; 16(1):31-4. PubMed ID: 8869537
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension.
    Kohyama T; Moriyama K; Kanai R; Kotani M; Uzawa K; Satoh T; Yorozu T
    PLoS One; 2015; 10(5):e0126979. PubMed ID: 25978517
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The precision and accuracy of Nellcor and Masimo oximeters at low oxygen saturations (70%) in newborn lambs.
    Dawson JA; Bastrenta P; Cavigioli F; Thio M; Ong T; Siew ML; Hooper SB; Davis PG
    Arch Dis Child Fetal Neonatal Ed; 2014 Jul; 99(4):F278-81. PubMed ID: 24596406
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Choice of oximeter affects apnea-hypopnea index.
    Zafar S; Ayappa I; Norman RG; Krieger AC; Walsleben JA; Rapoport DM
    Chest; 2005 Jan; 127(1):80-8. PubMed ID: 15653966
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The effect of averaging time on oximetry values in the premature infant.
    Ahmed SJ; Rich W; Finer NN
    Pediatrics; 2010 Jan; 125(1):e115-21. PubMed ID: 20026496
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Performance Evaluation of New-Generation Pulse Oximeters in the NICU: Observational Study.
    Nizami S; Greenwood K; Barrowman N; Harrold J
    Cardiovasc Eng Technol; 2015 Sep; 6(3):383-91. PubMed ID: 26577369
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Pulse oximetry fails to accurately detect low levels of arterial hemoglobin oxygen saturation in dogs.
    Sidi A; Rush W; Gravenstein N; Ruiz B; Paulus DA; Davis RF
    J Clin Monit; 1987 Oct; 3(4):257-62. PubMed ID: 3681359
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Accuracy of measurements of Kontrol 7840, Nellcor N200 and Radiometer OX13 pulse oximeters in infants and young children].
    Poets CF; Seidenberg J; Wilken M; von der Hardt H
    Klin Padiatr; 1993; 205(2):107-10. PubMed ID: 8487476
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 24.