These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 11905561)

  • 1. Selection of elastomeric materials for compliant-layered total hip arthroplasty.
    Quigley FP; Buggy M; Birkinshaw C
    Proc Inst Mech Eng H; 2002; 216(1):77-83. PubMed ID: 11905561
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Compliant layer bearings in artificial joints. Part 2: simulator and fatigue testing to assess the durability of the interface between an elastomeric layer and a rigid substrate.
    Jones E; Scholes SC; Burgess IC; Ash HE; Unsworth A
    Proc Inst Mech Eng H; 2009 Jan; 223(1):1-12. PubMed ID: 19239063
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Compliant layer bearings in artificial joints. Part 1: the effects of different manufacturing techniques on the interface strength between an elastomeric layer and a rigid substrate.
    Burgess IC; Jones E; Scholes SC; Unsworth A
    Proc Inst Mech Eng H; 2008 Aug; 222(6):853-64. PubMed ID: 18935802
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Soft layered prostheses for arthritic hip joints: a study of materials degradation.
    Blamey J; Rajan S; Unsworth A; Dawber R
    J Biomed Eng; 1991 May; 13(3):180-4. PubMed ID: 1870325
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analysis and evaluation of a biomedical polycarbonate urethane tested in an in vitro study and an ovine arthroplasty model. Part I: materials selection and evaluation.
    Khan I; Smith N; Jones E; Finch DS; Cameron RE
    Biomaterials; 2005 Feb; 26(6):621-31. PubMed ID: 15282140
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Compliant layer acetabular cups: friction testing of a range of materials and designs for a new generation of prosthesis that mimics the natural joint.
    Scholes SC; Burgess IC; Marsden HR; Unsworth A; Jones E; Smith N
    Proc Inst Mech Eng H; 2006 Jul; 220(5):583-96. PubMed ID: 16898216
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysis and evaluation of a biomedical polycarbonate urethane tested in an in vitro study and an ovine arthroplasty model. Part II: in vivo investigation.
    Khan I; Smith N; Jones E; Finch DS; Cameron RE
    Biomaterials; 2005 Feb; 26(6):633-43. PubMed ID: 15282141
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Aging performance of a compliant layer bearing acetabular prosthesis in an ovine hip arthroplasty model.
    Carbone A; Howie DW; McGee M; Field J; Pearcy M; Smith N; Jones E
    J Arthroplasty; 2006 Sep; 21(6):899-906. PubMed ID: 16950047
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stress analysis of cushion form bearings for total hip replacements.
    Jin ZM; Dowson D; Fisher J
    Proc Inst Mech Eng H; 1991; 205(4):219-26. PubMed ID: 1670079
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [A study of the mechanical properties of alumina-on-alumina total hip prosthesis (author's transl)].
    Boutin P; Blanquaert D
    Rev Chir Orthop Reparatrice Appar Mot; 1981; 67(3):279-87. PubMed ID: 6456504
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Alternative bearing surfaces in total hip arthroplasty.
    Tuli R; Parvizi J
    Expert Rev Med Devices; 2005 Jul; 2(4):445-52. PubMed ID: 16293083
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design aspects of compliant, soft layer bearings for an experimental hip prosthesis.
    Scholes SC; Unsworth A; Blamey JM; Burgess IC; Jones E; Smith N
    Proc Inst Mech Eng H; 2005; 219(2):79-87. PubMed ID: 15819479
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Factors and interactions affecting the performance of polyurethane elastomers in medical devices.
    Coury AJ; Slaikeu PC; Cahalan PT; Stokes KB; Hobot CM
    J Biomater Appl; 1988 Oct; 3(2):130-79. PubMed ID: 3060584
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Bearing selection in total hip arthroplasty].
    Sonntag R; Reinders J; Müller U; Kretzer JP
    Z Orthop Unfall; 2015 Dec; 153(6):587-96. PubMed ID: 26367145
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding.
    Zaki M; Aljinaidi A; Hamed M
    Biomed Mater Eng; 2003; 13(3):205-21. PubMed ID: 12883170
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Study of friction and loosening in hip endoprostheses].
    Dovzak Bajs I; Cvjetko I; Car D; Kokić V
    Acta Med Croatica; 2002; 56(4-5):151-5. PubMed ID: 12768893
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Development of artificial disc nucleus materials (semicrystalline polyvinyl alcohol hydrogel elastomers)].
    Gu Z; Ma Y; Gao J; Liu J; Li Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2004 Jun; 21(3):347-9. PubMed ID: 15250130
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Thermoplastic Elastomers: Materials for Heart Assist Devices.
    Piegat A; Fray ME
    Polim Med; 2016; 46(1):79-87. PubMed ID: 28397422
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomaterials in total joint replacement.
    Katti KS
    Colloids Surf B Biointerfaces; 2004 Dec; 39(3):133-42. PubMed ID: 15556342
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.