These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 11908485)

  • 1. Assessment of the ergonomically optimal operating surface height for laparoscopic surgery.
    van Veelen MA; Kazemier G; Koopman J; Goossens RH; Meijer DW
    J Laparoendosc Adv Surg Tech A; 2002 Feb; 12(1):47-52. PubMed ID: 11908485
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ergonomics: requirements for adjusting the height of laparoscopic operating tables.
    Matern U; Waller P; Giebmeyer C; Rückauer KD; Farthmann EH
    JSLS; 2001; 5(1):7-12. PubMed ID: 11303999
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An ergonomic study of the optimum operating table height for laparoscopic surgery.
    Berquer R; Smith WD; Davis S
    Surg Endosc; 2002 Mar; 16(3):416-21. PubMed ID: 11928019
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ergonomic Benefits From a Laparoscopic Instrument With Rotatable Handle Piece Depend on the Area of the Operating Field and Working Height.
    Steinhilber B; Reiff F; Seibt R; Rieger MA; Martus P; Kraemer B; Rothmund R
    Hum Factors; 2017 Nov; 59(7):1048-1065. PubMed ID: 28628750
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ergonomic deficiencies in the operating room: examples from minimally invasive surgery.
    Matern U
    Work; 2009; 33(2):165-8. PubMed ID: 19713625
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative analysis of low-back loading on chiropractors using various workstation table heights and performing various tasks.
    Lorme KJ; Naqvi SA
    J Manipulative Physiol Ther; 2003 Jan; 26(1):25-33. PubMed ID: 12532135
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ergonomic assessment of optimum operating table height for hand-assisted laparoscopic surgery.
    Manasnayakorn S; Cuschieri A; Hanna GB
    Surg Endosc; 2009 Apr; 23(4):783-9. PubMed ID: 18629584
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ergonomics in the operating room: protecting the surgeon.
    Rosenblatt PL; McKinney J; Adams SR
    J Minim Invasive Gynecol; 2013; 20(6):744. PubMed ID: 23969139
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimal ergonomics for laparoscopic surgery in minimally invasive surgery suites: a review and guidelines.
    van Det MJ; Meijerink WJ; Hoff C; Totté ER; Pierie JP
    Surg Endosc; 2009 Jun; 23(6):1279-85. PubMed ID: 18830751
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of aviation snip design and task height on upper extremity muscular activity and wrist posture.
    Anton D; Gerr F; Meyers A; Cook TM; Rosecrance JC; Reynolds J
    J Occup Environ Hyg; 2007 Feb; 4(2):99-113. PubMed ID: 17175513
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The operation room as a hostile environment for surgeons: physical complaints during and after laparoscopy.
    Sari V; Nieboer TE; Vierhout ME; Stegeman DF; Kluivers KB
    Minim Invasive Ther Allied Technol; 2010 Apr; 19(2):105-9. PubMed ID: 20158410
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Design of a prototype operating seat with SESAM (Ergonomic System of Mobile Forearm Rests) mobile armrests designed to optimize the surgeon's ergonomy during pelvic laparoscopy].
    Lorin S; Poumarat G; Memeteau Y; Wattiez A; Tostain J
    Prog Urol; 2004 Dec; 14(6):1181-7. PubMed ID: 15751414
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Can armrests improve comfort and task performance in laparoscopic surgery?
    Galleano R; Carter F; Brown S; Frank T; Cuschieri A
    Ann Surg; 2006 Mar; 243(3):329-33. PubMed ID: 16495696
    [TBL] [Abstract][Full Text] [Related]  

  • 14. New ergonomic design criteria for handles of laparoscopic dissection forceps.
    van Veelen ; Meijer DW; Goossens RH; Snijders CJ
    J Laparoendosc Adv Surg Tech A; 2001 Feb; 11(1):17-26. PubMed ID: 11444319
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improved usability of a new handle design for laparoscopic dissection forceps.
    Veelen MA; Meijer DW; Goossens RH; Snijders CJ; Jakimowicz JJ
    Surg Endosc; 2002 Jan; 16(1):201-7. PubMed ID: 11961640
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Perceived exertion and discomfort associated with driving screws at various work locations and at different work frequencies.
    Ulin SS; Armstrong TJ; Snook SH; Keyserling WM
    Ergonomics; 1993 Jul; 36(7):833-46. PubMed ID: 8339721
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The viewpoint-specific failure of modern 3D displays in laparoscopic surgery.
    Sakata S; Grove PM; Hill A; Watson MO; Stevenson AR
    Langenbecks Arch Surg; 2016 Nov; 401(7):1007-1018. PubMed ID: 27539218
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ergonomic evaluation of the operating characteristics of the 6MF-30 portable pneumatic extinguisher.
    Wang L; Li W; Chen J
    Appl Ergon; 2015 Nov; 51():39-43. PubMed ID: 26154202
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimizing integration of electrosurgical hand controls within a laparoscopic surgical tool.
    Rousek JB; Brown-Clerk B; Lowndes BR; Balogh BJ; Hallbeck MS
    Minim Invasive Ther Allied Technol; 2012 May; 21(3):222-33. PubMed ID: 21919825
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ergonomic status of laparoscopic urologic surgery: survey results from 241 urologic surgeons in china.
    Liang B; Qi L; Yang J; Cao Z; Zu X; Liu L; Wang L
    PLoS One; 2013; 8(7):e70423. PubMed ID: 23936202
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.