284 related articles for article (PubMed ID: 11914663)
1. Presurgical localization of abnormal parathyroid glands using a single injection of Tc-99m sestamibi: comparison of high-resolution parallel-hole and pinhole collimators, and interobserver and intraobserver variation.
Arveschoug AK; Bertelsen H; Vammen B
Clin Nucl Med; 2002 Apr; 27(4):249-54. PubMed ID: 11914663
[TBL] [Abstract][Full Text] [Related]
2. Preoperative dual-phase parathyroid imaging with tc-99m-sestamibi: accuracy and reproducibility of the pinhole collimator with and without oblique images.
Arveschoug AK; Bertelsen H; Vammen B; Brøchner-Mortensen J
Clin Nucl Med; 2007 Jan; 32(1):9-12. PubMed ID: 17179795
[TBL] [Abstract][Full Text] [Related]
3. Parathyroid imaging: the importance of pinhole collimation with both single- and dual-tracer acquisition.
Klingensmith WC; Koo PJ; Summerlin A; Fehrenbach BW; Karki R; Shulman BC; Raeburn CD; McIntyre RC
J Nucl Med Technol; 2013 Jun; 41(2):99-104. PubMed ID: 23539762
[TBL] [Abstract][Full Text] [Related]
4. [Evaluation of parathyroid imaging methods with 99mTc-MIBI--the comparison of planar images obtained using a pinhole collimator and a parallel-hole collimator].
Fujii H; Iwasaki R; Ogawa K; Hashimoto J; Nakamura K; Kunieda E; Sanmiya T; Kubo A; Inagaki K
Kaku Igaku; 1999 Jul; 36(5):425-33. PubMed ID: 10466305
[TBL] [Abstract][Full Text] [Related]
5. Double-phase Tc-99m sestamibi scintigraphy in the preoperative location of lesions causing hyperparathyroidism.
Blanco I; Carril JM; Banzo I; Quirce R; Gutierrez C; Uriarte I; Montero A; Vallina NK
Clin Nucl Med; 1998 May; 23(5):291-7. PubMed ID: 9596153
[TBL] [Abstract][Full Text] [Related]
6. Presurgical localization of abnormal parathyroid glands using a single injection of technetium-99m methoxyisobutylisonitrile: comparison of different techniques including factor analysis of dynamic structures.
Blocklet D; Martin P; Schoutens A; Verhas M; Hooghe L; Kinnaert P
Eur J Nucl Med; 1997 Jan; 24(1):46-51. PubMed ID: 9044876
[TBL] [Abstract][Full Text] [Related]
7. Improved delineation of parathyroid lesions in patients with chronic renal failure using magnified pinhole imaging.
Ali L; Loutfi I; Biswas G; Hadi N; Girgis T
J Nucl Med Technol; 2011 Mar; 39(1):35-9. PubMed ID: 21321253
[TBL] [Abstract][Full Text] [Related]
8. The usefulness of Tc-99m tetrofosmin scintigraphy in the diagnosis and localization of hyperfunctioning parathyroid glands.
Vallejos V; Martin-Comin J; Gonzalez MT; Rafecas R; Muñoz A; Fernãndez A; Mora J; Ramos M
Clin Nucl Med; 1999 Dec; 24(12):959-64. PubMed ID: 10595477
[TBL] [Abstract][Full Text] [Related]
9. Comparison of parathyroid imaging with technetium-99m-pertechnetate/sestamibi subtraction, double-phase technetium-99m-sestamibi and technetium-99m-sestamibi SPECT.
Chen CC; Holder LE; Scovill WA; Tehan AM; Gann DS
J Nucl Med; 1997 Jun; 38(6):834-9. PubMed ID: 9189125
[TBL] [Abstract][Full Text] [Related]
10. Parathyroid imaging: the importance of dual-radiopharmaceutical simultaneous acquisition with 99mTc-sestamibi and 123I.
Caveny SA; Klingensmith WC; Martin WE; Sage-El A; McIntyre RC; Raeburn C; Wolfe P
J Nucl Med Technol; 2012 Jun; 40(2):104-10. PubMed ID: 22566587
[TBL] [Abstract][Full Text] [Related]
11. Clinical role of 99mTcO4/MIBI scan, ultrasound and intra-operative gamma probe in the performance of unilateral and minimally invasive surgery in primary hyperparathyroidism.
Casara D; Rubello D; Pelizzo MR; Shapiro B
Eur J Nucl Med; 2001 Sep; 28(9):1351-9. PubMed ID: 11585294
[TBL] [Abstract][Full Text] [Related]
12. Pinhole versus parallel-hole collimators for parathyroid imaging: an intraindividual comparison.
Tomas MB; Pugliese PV; Tronco GG; Love C; Palestro CJ; Nichols KJ
J Nucl Med Technol; 2008 Dec; 36(4):189-94. PubMed ID: 19008287
[TBL] [Abstract][Full Text] [Related]
13. Preoperative parathyroid scintigraphic lesion localization: accuracy of various types of readings.
Nichols KJ; Tomas MB; Tronco GG; Rini JN; Kunjummen BD; Heller KS; Sznyter LA; Palestro CJ
Radiology; 2008 Jul; 248(1):221-32. PubMed ID: 18483228
[TBL] [Abstract][Full Text] [Related]
14. Prospective comparison of technetium-99m-sestamibi/iodine-123 radionuclide scan versus high-resolution ultrasonography for the preoperative localization of abnormal parathyroid glands in patients with previously unoperated primary hyperparathyroidism.
Casas AT; Burke GJ; Sathyanarayana ; Mansberger AR; Wei JP
Am J Surg; 1993 Oct; 166(4):369-73. PubMed ID: 8214295
[TBL] [Abstract][Full Text] [Related]
15. The diagnostic utility of dual phase Tc-99m sestamibi parathyroid imaging.
Klieger P; O'Mara R
Clin Nucl Med; 1998 Apr; 23(4):208-11. PubMed ID: 9554190
[TBL] [Abstract][Full Text] [Related]
16. The usefulness of neck pinhole SPECT as a complementary tool to planar scintigraphy in primary and secondary hyperparathyroidism.
Spanu A; Falchi A; Manca A; Marongiu P; Cossu A; Pisu N; Chessa F; Nuvoli S; Madeddu G
J Nucl Med; 2004 Jan; 45(1):40-8. PubMed ID: 14734671
[TBL] [Abstract][Full Text] [Related]
17. Ultrasonography for preoperative localization of enlarged parathyroid glands in primary hyperparathyroidism: comparison with (99m)technetium sestamibi scintigraphy.
Haber RS; Kim CK; Inabnet WB
Clin Endocrinol (Oxf); 2002 Aug; 57(2):241-9. PubMed ID: 12153604
[TBL] [Abstract][Full Text] [Related]
18. Technetium 99m tetrofosmin parathyroid imaging. Results with double-phase study and SPECT in primary and secondary hyperparathyroidism.
Gallowitsch HJ; Mikosch P; Kresnik E; Gomez I; Lind P
Invest Radiol; 1997 Aug; 32(8):459-65. PubMed ID: 9258734
[TBL] [Abstract][Full Text] [Related]
19. Dual-phase 99mTc-sestamibi imaging: its utility in parathyroid hyperplasia and use of immediate/delayed image ratios to improve diagnosis of hyperparathyroidism.
Gordon L; Burkhalter W; Mah E
J Nucl Med Technol; 2002 Dec; 30(4):179-84. PubMed ID: 12446751
[TBL] [Abstract][Full Text] [Related]
20. Advantages of pinhole collimator double-phase scintigraphy with 99mTc-MIBI in secondary hyperparathyroidism.
Fuster D; Depetris M; Torregrosa JV; Squarcia M; Paschoalin RP; Mayoral M; Granados U; Colletti PM; Rubello D; Pons F
Clin Nucl Med; 2013 Nov; 38(11):878-81. PubMed ID: 24089071
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]