373 related articles for article (PubMed ID: 11922203)
21. A new reconstruction strategy for image improvement in pinhole SPECT.
Zeniya T; Watabe H; Aoi T; Kim KM; Teramoto N; Hayashi T; Sohlberg A; Kudo H; Iida H
Eur J Nucl Med Mol Imaging; 2004 Aug; 31(8):1166-72. PubMed ID: 15029462
[TBL] [Abstract][Full Text] [Related]
22. Evaluation of reconstruction techniques in regional cerebral blood flow SPECT using trade-off plots: a Monte Carlo study.
Olsson A; Arlig A; Carlsson GA; Gustafsson A
Nucl Med Commun; 2007 Sep; 28(9):719-25. PubMed ID: 17667751
[TBL] [Abstract][Full Text] [Related]
23. LOR-OSEM: statistical PET reconstruction from raw line-of-response histograms.
Kadrmas DJ
Phys Med Biol; 2004 Oct; 49(20):4731-44. PubMed ID: 15566171
[TBL] [Abstract][Full Text] [Related]
24. Improved quantification in multiple-pinhole SPECT by anatomy-based reconstruction using microCT information.
Vanhove C; Defrise M; Bossuyt A; Lahoutte T
Eur J Nucl Med Mol Imaging; 2011 Jan; 38(1):153-65. PubMed ID: 20882279
[TBL] [Abstract][Full Text] [Related]
25. Noise reduction in oncology FDG PET images by iterative reconstruction: a quantitative assessment.
Riddell C; Carson RE; Carrasquillo JA; Libutti SK; Danforth DN; Whatley M; Bacharach SL
J Nucl Med; 2001 Sep; 42(9):1316-23. PubMed ID: 11535719
[TBL] [Abstract][Full Text] [Related]
26. Accelerated 3D-OSEM image reconstruction using a Beowulf PC cluster for pinhole SPECT.
Zeniya T; Watabe H; Sohlberg A; Iida H
Ann Nucl Med; 2007 Nov; 21(9):537-43. PubMed ID: 18030588
[TBL] [Abstract][Full Text] [Related]
27. Quantitative accuracy of clinical 99mTc SPECT/CT using ordered-subset expectation maximization with 3-dimensional resolution recovery, attenuation, and scatter correction.
Zeintl J; Vija AH; Yahil A; Hornegger J; Kuwert T
J Nucl Med; 2010 Jun; 51(6):921-8. PubMed ID: 20484423
[TBL] [Abstract][Full Text] [Related]
28. Correction for respiration artefacts in myocardial perfusion SPECT is more effective when reconstructions supporting collimator detector response compensation are applied.
Kovalski G; Keidar Z; Frenkel A; Israel O; Azhari H
J Nucl Cardiol; 2009; 16(6):949-55. PubMed ID: 19777319
[TBL] [Abstract][Full Text] [Related]
29. Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation.
Dewaraja YK; Wilderman SJ; Ljungberg M; Koral KF; Zasadny K; Kaminiski MS
J Nucl Med; 2005 May; 46(5):840-9. PubMed ID: 15872359
[TBL] [Abstract][Full Text] [Related]
30. Is iterative reconstruction an alternative to filtered backprojection in routine processing of dopamine transporter SPECT studies?
Koch W; Hamann C; Welsch J; Pöpperl G; Radau PE; Tatsch K
J Nucl Med; 2005 Nov; 46(11):1804-11. PubMed ID: 16269593
[TBL] [Abstract][Full Text] [Related]
31. Automatic estimation of detector radial position for contoured SPECT acquisition using CT images on a SPECT/CT system.
Liu RR; Erwin WD
Med Phys; 2006 Aug; 33(8):2800-8. PubMed ID: 16964856
[TBL] [Abstract][Full Text] [Related]
32. Evaluation of quantitative (90)Y SPECT based on experimental phantom studies.
Minarik D; Sjögreen Gleisner K; Ljungberg M
Phys Med Biol; 2008 Oct; 53(20):5689-703. PubMed ID: 18812648
[TBL] [Abstract][Full Text] [Related]
33. Pediatric 99mTc-DMSA SPECT performed by using iterative reconstruction with isotropic resolution recovery: improved image quality and reduced radiopharmaceutical activity.
Sheehy N; Tetrault TA; Zurakowski D; Vija AH; Fahey FH; Treves ST
Radiology; 2009 May; 251(2):511-6. PubMed ID: 19304919
[TBL] [Abstract][Full Text] [Related]
34. [Accuracy of Resolution Recovery in PSF-based Fully-3D PET Image Reconstruction: Simulation and Phantom Study in Multicenter Trial].
Kangai Y; Odajima S; Matsutomo N; Kamiya T; Mizuta T; Onishi H
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2016 Mar; 72(3):209-17. PubMed ID: 27000669
[TBL] [Abstract][Full Text] [Related]
35. Quantitative CBF measurement using an integrated SPECT/CT system: validation of three-dimensional ordered-subset expectation maximization and CT-based attenuation correction by comparing with O-15 water PET.
Shimosegawa E; Fujino K; Kato H; Hatazawa J
Ann Nucl Med; 2013 Nov; 27(9):822-33. PubMed ID: 23824783
[TBL] [Abstract][Full Text] [Related]
36. Intrinsic uniformity requirements for pinhole SPECT.
Seret A; Bleeser F
J Nucl Med Technol; 2006 Mar; 34(1):43-7. PubMed ID: 16517968
[TBL] [Abstract][Full Text] [Related]
37. Localization of temporal epilepsy foci by subtraction ictal perfusion single photon emission computed tomography is enhanced when using 3D-OSEM iterative reconstruction.
Ben Mahmoud S; Maillard L; Poussier S; Koessler L; El Khawaja MS; Laurens MH; Vespignani H; Karcher G; Marie PY
Nucl Med Commun; 2009 Nov; 30(11):846-53. PubMed ID: 19707167
[TBL] [Abstract][Full Text] [Related]
38. [Simultaneous spatial resolution correction in SPECT reconstruction using OS-EM algorithm].
Maeda H; Yamaki N; Natsume T; Takeda K; Hasebe S; Kinda A; Motomura N
Igaku Butsuri; 2004; 24(2):61-71. PubMed ID: 15383710
[TBL] [Abstract][Full Text] [Related]
39. Performance of 3DOSEM and MAP algorithms for reconstructing low count SPECT acquisitions.
Grootjans W; Meeuwis AP; Slump CH; de Geus-Oei LF; Gotthardt M; Visser EP
Z Med Phys; 2016 Dec; 26(4):311-322. PubMed ID: 26725165
[TBL] [Abstract][Full Text] [Related]
40. Quantitative rotating multisegment slant-hole SPECT mammography with attenuation and collimator-detector response compensation.
Xu J; Liu C; Wang Y; Frey EC; Tsui BM
IEEE Trans Med Imaging; 2007 Jul; 26(7):906-16. PubMed ID: 17649904
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]