BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 11924968)

  • 1. A selective optode membrane for histidine based on fluorescence enhancement of meso-meso-linked porphyrin dimer.
    Yang R; Wang K; Long L; Xiao D; Yang X; Tan W
    Anal Chem; 2002 Mar; 74(5):1088-96. PubMed ID: 11924968
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fluorescent sensor for imidazole derivatives based on monomer-dimer equilibrium of a zinc porphyrin complex in a polymeric film.
    Zhang Y; Yang R; Liu F; Li K
    Anal Chem; 2004 Dec; 76(24):7336-45. PubMed ID: 15595877
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A reversible optode membrane for picric acid based on the fluorescence quenching of pyrene.
    Zeng HH; Wang KM; Liu CL; Yu RQ
    Talanta; 1993 Oct; 40(10):1569-73. PubMed ID: 18965822
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a novel fluorimetric bulk optode membrane based on meso-tetrakis(2-hydroxynaphthyl) porphyrin (MTHNP) for highly sensitive and selective monitoring of trace amounts of Hg2+ ions.
    Shamsipur M; Sadeghi M; Beyzavi MH; Sharghi H
    Mater Sci Eng C Mater Biol Appl; 2015 Mar; 48():424-33. PubMed ID: 25579943
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An optical fiber chemical sensor for mercury ions based on a porphyrin dimer.
    Zhang XB; Guo CC; Li ZZ; Shen GL; Yu RQ
    Anal Chem; 2002 Feb; 74(4):821-5. PubMed ID: 11866062
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fluoride-selective optical sensor based on aluminum(III)-octaethylporphyrin in thin polymeric film: further characterization and practical application.
    Badr IH; Meyerhoff ME
    Anal Chem; 2005 Oct; 77(20):6719-28. PubMed ID: 16223262
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An optode sensor for Cu2+ with high selectivity based on porphyrin derivative appended with bipyridine.
    Luo HY; Zhang XB; Jiang JH; Li CY; Peng J; Shen GL; Yu RQ
    Anal Sci; 2007 May; 23(5):551-5. PubMed ID: 17495400
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of ion-carrier substituents on the potentiometric-response characteristics in anion-selective membrane electrodes based on iron porphyrins.
    Shahrokhian S; Seifi H; Bagherzadeh M; Mousavi SR
    Chemphyschem; 2004 May; 5(5):652-60. PubMed ID: 15179717
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Novel Fluorimetric Bulk Optode Membrane Based on NOS Tridentate Schiff Base for Selective Optical Sensing of Al
    Abdel Aziz AA; Mohamed RG; Elantabli FM; El-Medani SM
    J Fluoresc; 2016 Nov; 26(6):1927-1938. PubMed ID: 27492681
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Anion chelation-induced porphyrin protonation and its application for chloride anion sensing.
    Zhang Y; Li MX; Lü MY; Yang RH; Liu F; Li KA
    J Phys Chem A; 2005 Aug; 109(33):7442-8. PubMed ID: 16834113
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A fluorescence enhancement-based sensor using glycosylated metalloporphyrin as a recognition element for levamisole assay.
    Gong FC; Wu DX; Cao Z; He XC
    Biosens Bioelectron; 2006 Sep; 22(3):423-8. PubMed ID: 16701990
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An optical sensor for mercury ion based on the fluorescence quenching of tetra(p-dimethylaminophenyl)porphyrin.
    Yang Y; Jiang J; Shen G; Yu R
    Anal Chim Acta; 2009 Mar; 636(1):83-8. PubMed ID: 19231360
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Polymeric optical sensors for selective and sensitive nitrite detection using cobalt(III) corrole and rhodium(III) porphyrin as ionophores.
    Yang S; Wo Y; Meyerhoff ME
    Anal Chim Acta; 2014 Sep; 843():89-96. PubMed ID: 25150700
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An oxo-bacteriochlorin derivative for long-wavelength fluorescence ratiometric alcohol sensing.
    Takano K; Sasaki S; Citterio D; Tamiaki H; Suzuki K
    Analyst; 2010 Sep; 135(9):2334-9. PubMed ID: 20614089
    [TBL] [Abstract][Full Text] [Related]  

  • 15. PVC-Based Mn(III) Porphyrin Membrane-Coated Graphite Electrode for Determination of Histidine.
    Amini MK; Shahrokhian S; Tangestaninejad S
    Anal Chem; 1999 Jul; 71(13):2502-5. PubMed ID: 21662794
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A colorimetric paper-based optode sensor for highly sensitive and selective determination of thiocyanate in urine sample using cobalt porphyrin derivative.
    Wirojsaengthong S; Aryuwananon D; Aeungmaitrepirom W; Pulpoka B; Tuntulani T
    Talanta; 2021 Aug; 231():122371. PubMed ID: 33965036
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optical acetylcholine sensor based on free base porphyrin as a chromoionophore.
    Mroczkiewicz M; Pietrzak M; Górski Ł; Malinowska E
    Analyst; 2011 Sep; 136(18):3770-6. PubMed ID: 21776519
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A sensitive optode membrane for berberine using conjugated polymer as sensing material.
    Huang HM; Wang KM; Yang RH; Yang XH; Huang SS; Xiao D; Feng F
    Anal Sci; 2002 Oct; 18(10):1111-5. PubMed ID: 12400656
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An optical sensor for mercuric ion based on immobilization of Rhodamine B derivative in PVC membrane.
    Ling L; Zhao Y; Du J; Xiao D
    Talanta; 2012 Mar; 91():65-71. PubMed ID: 22365681
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A selective optical sensor for beryllium determination based on incorporating of 1,8-dihydroxyanthrone in a poly (vinyl chloride) membrane.
    Beiraghi A; Babaee S; Roshdi M
    J Hazard Mater; 2011 Jun; 190(1-3):962-8. PubMed ID: 21536382
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.