143 related articles for article (PubMed ID: 11931466)
1. A flattening filter for brachytherapy skin irradiation.
Kron T; Haque M; Foulke K; Jeraj R
Phys Med Biol; 2002 Mar; 47(5):713-22. PubMed ID: 11931466
[TBL] [Abstract][Full Text] [Related]
2. Optimal flattening filter shape of a surface brachytherapy applicator.
Jeraj R; Sarvary A; Kron T
Phys Med Biol; 2002 Mar; 47(5):723-35. PubMed ID: 11931467
[TBL] [Abstract][Full Text] [Related]
3. Comparison of
Safigholi H; Meigooni AS; Song WY
Med Phys; 2017 Sep; 44(9):4426-4436. PubMed ID: 28494095
[TBL] [Abstract][Full Text] [Related]
4. Design and dosimetric characteristics of a high dose rate remotely afterloaded endocavitary applicator system.
Meigooni AS; Zhu Y; Williamson JF; Myerson RJ; Teague S; Löffler E; Nussbaum GH; Klein EE; Kodner IJ
Int J Radiat Oncol Biol Phys; 1996 Mar; 34(5):1153-63. PubMed ID: 8600101
[TBL] [Abstract][Full Text] [Related]
5. Dosimetric characterization of a novel intracavitary mold applicator for 192Ir high dose rate endorectal brachytherapy treatment.
Poon E; Reniers B; Devic S; Vuong T; Verhaegen F
Med Phys; 2006 Dec; 33(12):4515-26. PubMed ID: 17278803
[TBL] [Abstract][Full Text] [Related]
6. Surface applicator of a miniature X-ray tube for superficial electronic brachytherapy of skin cancer.
Kim HN; Lee JH; Park HB; Kim HJ; Cho SO
Med Phys; 2018 Jan; 45(1):29-36. PubMed ID: 29106708
[TBL] [Abstract][Full Text] [Related]
7. Design and characterization of flattening filter for high dose rate
Ghobadi P; Farhood B; Ghorbani M; Mohseni M
Comput Biol Med; 2020 Aug; 123():103878. PubMed ID: 32658791
[TBL] [Abstract][Full Text] [Related]
8.
Hadadi A; Ghanavati S
Appl Radiat Isot; 2023 Jul; 197():110786. PubMed ID: 37023694
[TBL] [Abstract][Full Text] [Related]
9. Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions.
Candela-Juan C; Niatsetski Y; van der Laarse R; Granero D; Ballester F; Perez-Calatayud J; Vijande J
Med Phys; 2016 Apr; 43(4):1639. PubMed ID: 27036563
[TBL] [Abstract][Full Text] [Related]
10. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate
Ma Y; Vijande J; Ballester F; Tedgren ÅC; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith R; Chamberland MJP; Thomson RM; Verhaegen F; Beaulieu L
Med Phys; 2017 Nov; 44(11):5961-5976. PubMed ID: 28722180
[TBL] [Abstract][Full Text] [Related]
11. Dosimetric optimization of a conical breast brachytherapy applicator for improved skin dose sparing.
Yang Y; Rivard MJ
Med Phys; 2010 Nov; 37(11):5665-71. PubMed ID: 21158278
[TBL] [Abstract][Full Text] [Related]
12. A novel rectal applicator for contact radiotherapy with HDR
Bellezzo M; Fonseca GP; Verrijssen AS; Voncken R; Van den Bosch MR; Yoriyaz H; Reniers B; Berbée M; Van Limbergen EJ; Verhaegen F
Brachytherapy; 2018; 17(6):1037-1044. PubMed ID: 30122346
[TBL] [Abstract][Full Text] [Related]
13. Advanced design, simulation, and dosimetry of a novel rectal applicator for contact brachytherapy with a conventional HDR
Bellezzo M; Fonseca GP; Voncken R; Verrijssen AS; Van Beveren C; Roelofs E; Yoriyaz H; Reniers B; Van Limbergen EJ; Berbée M; Verhaegen F
Brachytherapy; 2020; 19(4):544-553. PubMed ID: 32386884
[TBL] [Abstract][Full Text] [Related]
14. A monte carlo dosimetry study of vaginal 192Ir brachytherapy applications with a shielded cylindrical applicator set.
Lymperopoulou G; Pantelis E; Papagiannis P; Rozaki-Mavrouli H; Sakelliou L; Baltas D; Karaiskos P
Med Phys; 2004 Nov; 31(11):3080-6. PubMed ID: 15587661
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of bone dose arising from skin cancer brachytherapy: A comparison between
Sheikholeslami S; Khodaverdian S; Hashemzaei F; Ghobadi P; Ghorbani M; Farhood B
Comput Methods Programs Biomed; 2021 Jun; 205():106089. PubMed ID: 33862569
[TBL] [Abstract][Full Text] [Related]
16. Monte Carlo simulations and radiation dosimetry measurements of peripherally applied HDR 192Ir breast brachytherapy D-shaped applicators.
Yang Y; Rivard MJ
Med Phys; 2009 Mar; 36(3):809-15. PubMed ID: 19378741
[TBL] [Abstract][Full Text] [Related]
17. Design and evaluation of a HDR skin applicator with flattening filter.
Granero D; Pérez-Calatayud J; Gimeno J; Ballester F; Casal E; Crispín V; van der Laarse R
Med Phys; 2008 Feb; 35(2):495-503. PubMed ID: 18383670
[TBL] [Abstract][Full Text] [Related]
18. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system.
Austerlitz C; Mota HC; Sempau J; Benhabib SM; Campos D; Allison R; DeAlmeida CE; Zhu D; Sibata CH
Med Phys; 2008 Dec; 35(12):5360-5. PubMed ID: 19175095
[TBL] [Abstract][Full Text] [Related]
19. Comparison of calibration procedures for 192Ir high-dose-rate brachytherapy sources.
Baltas D; Geramani K; Ioannidis GT; Hierholz K; Rogge B; Kolotas C; Müller-Sievers K; Milickovic N; Kober B; Zamboglou N
Int J Radiat Oncol Biol Phys; 1999 Feb; 43(3):653-61. PubMed ID: 10078653
[TBL] [Abstract][Full Text] [Related]
20. Dosimetric assessment of an air-filled balloon applicator in HDR vaginal cuff brachytherapy using the Monte Carlo method.
Jiang H; Badkul R; Pokhrel D
J Appl Clin Med Phys; 2018 May; 19(3):101-107. PubMed ID: 29493101
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]