149 related articles for article (PubMed ID: 11937141)
1. A prospective randomized comparison of the Wallace catheter and the Cook Echo-Tip catheter for ultrasound-guided embryo transfer.
Karande V; Hazlett D; Vietzke M; Gleicher N
Fertil Steril; 2002 Apr; 77(4):826-30. PubMed ID: 11937141
[TBL] [Abstract][Full Text] [Related]
2. Embryo transfer using the SureView catheter-beacon in the womb.
Allahbadia GN; Kadam K; Gandhi G; Arora S; Valliappan JB; Joshi A; Allahbadia S; Wolman I
Fertil Steril; 2010 Feb; 93(2):344-50. PubMed ID: 19268930
[TBL] [Abstract][Full Text] [Related]
3. A prospective randomized controlled trial of Wallace and Rocket embryo transfer catheters.
El-Shawarby SA; Ravhon A; Skull J; Ellenbogen A; Trew G; Lavery S
Reprod Biomed Online; 2008 Oct; 17(4):549-52. PubMed ID: 18854110
[TBL] [Abstract][Full Text] [Related]
4. Transvaginal versus transabdominal ultrasound guidance for embryo transfer in donor oocyte recipients: a randomized clinical trial.
Bodri D; Colodrón M; García D; Obradors A; Vernaeve V; Coll O
Fertil Steril; 2011 Jun; 95(7):2263-8, 2268.e1. PubMed ID: 21459374
[TBL] [Abstract][Full Text] [Related]
5. Effect of using an echogenic catheter for ultrasound-guided embryo transfer in an IVF programme: a prospective, randomized, controlled study.
Coroleu B; Barri PN; Carreras O; Belil I; Buxaderas R; Veiga A; Balasch J
Hum Reprod; 2006 Jul; 21(7):1809-15. PubMed ID: 16556674
[TBL] [Abstract][Full Text] [Related]
6. The choice of embryo transfer catheter affects embryo implantation after IVF.
Meriano J; Weissman A; Greenblatt EM; Ward S; Casper RF
Fertil Steril; 2000 Oct; 74(4):678-82. PubMed ID: 11020506
[TBL] [Abstract][Full Text] [Related]
7. Ultrasound-guided soft catheter embryo transfers will improve pregnancy rates in in-vitro fertilization.
Wood EG; Batzer FR; Go KJ; Gutmann JN; Corson SL
Hum Reprod; 2000 Jan; 15(1):107-12. PubMed ID: 10611197
[TBL] [Abstract][Full Text] [Related]
8. A new coaxial catheter system with an echodense tip for ultrasonographically guided embryo transfer.
Letterie GS; Marshall L; Angle M
Fertil Steril; 1999 Aug; 72(2):266-8. PubMed ID: 10438993
[TBL] [Abstract][Full Text] [Related]
9. Ultrasound-guided embryo transfer does not offer any benefit in clinical outcome: a randomized controlled trial.
Kosmas IP; Janssens R; De Munck L; Al Turki H; Van der Elst J; Tournaye H; Devroey P
Hum Reprod; 2007 May; 22(5):1327-34. PubMed ID: 17289683
[TBL] [Abstract][Full Text] [Related]
10. A review and meta-analysis of prospective trials comparing different catheters used for embryo transfer.
Buckett WM
Fertil Steril; 2006 Mar; 85(3):728-34. PubMed ID: 16500345
[TBL] [Abstract][Full Text] [Related]
11. A prospective randomized controlled trial comparing two embryo transfer catheters in an ART program.
Saldeen P; Abou-Setta AM; Bergh T; Sundström P; Holte J
Fertil Steril; 2008 Sep; 90(3):599-603. PubMed ID: 18054000
[TBL] [Abstract][Full Text] [Related]
12. Prospective randomized comparison of Wallace and Labotect embryo transfer catheters.
Ata B; Isiklar A; Balaban B; Urman B
Reprod Biomed Online; 2007 Apr; 14(4):471-6. PubMed ID: 17425830
[TBL] [Abstract][Full Text] [Related]
13. Cannulation of a resistant internal os with the malleable outer sheath of a coaxial soft embryo transfer catheter does not affect in vitro fertilization-embryo transfer outcome.
Silberstein T; Weitzen S; Frankfurter D; Trimarchi JR; Keefe DL; Plosker SM
Fertil Steril; 2004 Nov; 82(5):1402-6. PubMed ID: 15533367
[TBL] [Abstract][Full Text] [Related]
14. Modern embryo transfer catheters and pregnancy outcome: a prospective randomized trial.
McIlveen M; Lok FD; Pritchard J; Lashen H
Fertil Steril; 2005 Oct; 84(4):996-1000. PubMed ID: 16213855
[TBL] [Abstract][Full Text] [Related]
15. Transvaginal ultrasound-guided embryo transfer improves outcome in patients with previous failed in vitro fertilization cycles.
Anderson RE; Nugent NL; Gregg AT; Nunn SL; Behr BR
Fertil Steril; 2002 Apr; 77(4):769-75. PubMed ID: 11937132
[TBL] [Abstract][Full Text] [Related]
16. Blood on the embryo transfer catheter is associated with decreased rates of embryo implantation and clinical pregnancy with the use of in vitro fertilization-embryo transfer.
Goudas VT; Hammitt DG; Damario MA; Session DR; Singh AP; Dumesic DA
Fertil Steril; 1998 Nov; 70(5):878-82. PubMed ID: 9806570
[TBL] [Abstract][Full Text] [Related]
17. Transabdominal ultrasound-guided embryo transfer does not increase pregnancy rates in oocyte recipients.
García-Velasco JA; Isaza V; Martinez-Salazar J; Landazábal A; Requena A; Remohí J; Simón C
Fertil Steril; 2002 Sep; 78(3):534-9. PubMed ID: 12215329
[TBL] [Abstract][Full Text] [Related]
18. Transfer of embryos into the uterus: how much do technical factors affect pregnancy rates?
al-Shawaf T; Dave R; Harper J; Linehan D; Riley P; Craft I
J Assist Reprod Genet; 1993 Jan; 10(1):31-6. PubMed ID: 8499676
[TBL] [Abstract][Full Text] [Related]
19. [Effect of catheter choice during embryo transfer on the clinical outcome of in vitro fertilization-embryo transfer].
Ren XL; Liu P; Lian Y; Huang J; Zheng XY; Zhu YJ; Qiao J
Beijing Da Xue Xue Bao Yi Xue Ban; 2016 Oct; 48(5):905-909. PubMed ID: 27752179
[TBL] [Abstract][Full Text] [Related]
20. Large randomized trial comparing transabdominal ultrasound-guided embryo transfer with a technique based on uterine length measurement before embryo transfer.
Revelli A; Rovei V; Dalmasso P; Gennarelli G; Racca C; Evangelista F; Benedetto C
Ultrasound Obstet Gynecol; 2016 Sep; 48(3):289-95. PubMed ID: 26924732
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]