BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 11938723)

  • 1. [Study of the aluminum-zinc alloy as an alternative method of filtration in dental X-ray devices].
    Haiter CF; Bóscolo FN; Haiter Neto F; de Almeida SM
    Pesqui Odontol Bras; 2002; 16(1):77-82. PubMed ID: 11938723
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of aluminum-copper alloy filtration on photon spectra, air kerma rate and image contrast.
    Gonçalves A; Rollo JM; Gonçalves M; Haiter Neto F; Bóscolo FN
    Braz Dent J; 2004; 15(3):214-9. PubMed ID: 15798826
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of rare-earth filters on patient exposure and image contrast.
    Mauriello SM; Washburn DB; Matteson SR
    J Dent Res; 1987 Aug; 66(8):1326-30. PubMed ID: 3476600
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Niobium filtration of conventional and high-frequency x-ray generator beams for intraoral radiography. Effects on absorbed doses, image density and contrast, and photon spectra.
    Tetradis S; Scaf G; Lurie AG; Freedman ML
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 1995 Aug; 80(2):232-41. PubMed ID: 7552890
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Alternative X-ray filters for an intra-oral digital radiographic system.
    Stecke J; Cruz AD; Almeida SM; Bóscolo FN
    Dentomaxillofac Radiol; 2012 Jul; 41(5):361-6. PubMed ID: 22282509
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of Niobi-X filtration in intraoral radiology.
    White SC; Gratt BM
    Oral Surg Oral Med Oral Pathol; 1991 Dec; 72(6):746-55. PubMed ID: 1812457
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of thin K-edge filters on the image quality of D- and E-speed dental film.
    MacDonald-Jankowski DS; Lawinski CP; Payne M
    Dentomaxillofac Radiol; 1995 Feb; 24(1):23-9. PubMed ID: 8593903
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of E-speed film with added filtration.
    Ponce AZ; McDavid WD; Underhill TE; Morris CR
    Oral Surg Oral Med Oral Pathol; 1986 Mar; 61(3):297-9. PubMed ID: 3458135
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Variations in film exposure, effective kVp, and HVL among thirty-five dental x-ray units.
    Preece JW; Jensen CW
    Oral Surg Oral Med Oral Pathol; 1983 Dec; 56(6):655-61. PubMed ID: 6581465
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reducing radiation dose by application of optimized low-energy x-ray filters to K-edge imaging with a photon counting detector.
    Choi YN; Lee S; Kim HJ
    Phys Med Biol; 2016 Jan; 61(2):N35-49. PubMed ID: 26733235
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of image quality in dental radiography, part 1: phantom validity.
    Yoshiura K; Kawazu T; Chikui T; Tatsumi M; Tokumori K; Tanaka T; Kanda S
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 1999 Jan; 87(1):115-22. PubMed ID: 9927090
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Equivalent thicknesses of beam hardening filters consisting of aluminium, copper, Al/Cu and Al/Gold combinations and plumbiferous acrylic for 40 to 150 kVp diagnostic spectra.
    Homolka P; Figl M
    J Radiol Prot; 2018 Dec; 38(4):1269-1283. PubMed ID: 30115815
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of rare earth element added filters on the X-ray beam spectra: a Monte Carlo approach.
    Eskandarlou A; Jafari AA; Mohammadi M; Zehtabian M; Faghihi R; Shokri A; Pourolajal J
    J Xray Sci Technol; 2014; 22(4):459-70. PubMed ID: 25080114
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Are additional filters made of niobium superior to the copper filter in dental radiology?].
    Cordt I; Engelke W
    Schweiz Monatsschr Zahnmed; 1990; 100(10):1160-3. PubMed ID: 2237349
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Experimental assessment of the influence of beam hardening filters on image quality and patient dose in volumetric 64-slice X-ray CT scanners.
    Ay MR; Mehranian A; Maleki A; Ghadiri H; Ghafarian P; Zaidi H
    Phys Med; 2013 May; 29(3):249-60. PubMed ID: 22541061
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Parameterized algorithms for quantitative differentials in spectrally equivalent medical diagnostic x-ray beams.
    Okunade AA
    Med Phys; 2005 Jun; 32(6):1785-95. PubMed ID: 16013736
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of beam energy and filtration on the signal-to-noise ratio of the Dexis intraoral X-ray detector.
    Kitagawa H; Farman AG
    Dentomaxillofac Radiol; 2004 Jan; 33(1):21-4. PubMed ID: 15140818
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of aluminum-yttrium filtration for intraoral radiography.
    Farman AG; Perez C; Jacobson A; Kelly MS
    Oral Surg Oral Med Oral Pathol; 1989 Feb; 67(2):224-6. PubMed ID: 2919069
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A clinical comparison of speed group D and E dental x-ray films.
    Horton PS; Sippy FH; Kohout FJ; Nelson JF; Kienzle GC
    Oral Surg Oral Med Oral Pathol; 1984 Jul; 58(1):104-8. PubMed ID: 6589567
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Photon counting spectral CT: improved material decomposition with K-edge-filtered x-rays.
    Shikhaliev PM
    Phys Med Biol; 2012 Mar; 57(6):1595-615. PubMed ID: 22398007
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.